• 제목/요약/키워드: Fiber exposure

검색결과 268건 처리시간 0.022초

무근콘크리트 균열저감을 위한 배합설계 및 시공프로세스 수립에 대한 연구 (Study about cracking reducing of the concrete by utilizing fiber-reinforced admixture)

  • 김대건;최상환;문경식;조만기;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.140-141
    • /
    • 2014
  • Nowadays, as to increased the workability of the press concrete and decrease the cracking, the fiber-reinforced admixture has been widely used. As the low adhesion force between the paste and fiber-reinforced admixture, it was considered as could not be used in the structure. Even more, as the loss of flowability and the exposure of the fiber, further study is needed. In this study, as the different environment and position of the building, the dosages of the fiber-reinforced admixture has also been changed. The fundamental properties and cracking of fiber-reinforced concrete have been tested.

  • PDF

Experimental study on durability of strengthened corroded RC columns with FRP sheets in tidal zone of marine environment

  • Kashi, Amin;Ramezanianpour, Ali Akbar;Moodi, Faramarz
    • Computers and Concrete
    • /
    • 제19권4호
    • /
    • pp.339-346
    • /
    • 2017
  • The main objective of this paper was to illuminate the effect of marine environmental condition on durability of reinforced concrete (RC)-corroded columns strengthened with carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP) layers. Small-scale columns were prepared and corroded by an accelerated corrosion process. After strengthening, compressive strength tests were carried out on control and weathered specimens. In this research, a marine simulator was designed and constructed similar to the tidal zone of marine environment in south of Iran which was selected as a case study in this research. Mechanical properties of wrapped specimens were studied after placing them inside the simulator for 3000 hours. Marine environment decreased ultimate strength by 4.5% and 26.3% in CFRP and GFRP-wrapped columns, respectively. In some corroded-columns, strengthening was carried out after replacing damaged cover by self-compacted mortar. In this method, by confining with one layer of CFRP and GFRP, 4.2% and 22.4% reduction in ultimate strength was observed, respectively, after exposure. Furthermore, the elastic-brittle behavior has been verified in this retrofit method. Also results of tension tests revealed, the ultimate tensile strength was degraded by 2% and 28.8% in CFRP and GFRP sheets, respectively, after applying marine exposure.

Thermomechanical behavior of alkali-activated slag/fly ash composites with PVA fibers exposed to elevated temperatures

  • Kim, J.S.;Lee, H.K.
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 2021
  • The present study fabricated polyvinyl alcohol (PVA) fiber-reinforced alkali-activated slag/fly ash (AASF) composites with varying mixture ratios of slag and fly ash. The thermomechanical behaviors of the AASF composites exposed to 200, 400, 600, or 800℃ were evaluated by means of compressive strength test, visual observation, and fire resistance tests. X-ray diffractometry, mercury intrusion porosimetry, and thermogravimetry tests were performed to analyze the microstructure change of the AASF composites upon exposure to high temperatures. Specimens exhibited a gradual strength loss up to 600℃, while also showing a significant decrease in the strength above 600℃. The fire resistance test revealed the occurrence of an inflection point as indicated by an increase in the internal temperature at around 200℃. In addition, specimens showed the dehydration of C-S-H gel, the presence of åkermanite, gehlenite, and anorthite upon exposure to 800℃, which is associated with the formation of macropore population with pores having diameters of 1-3 ㎛ and 20-40 ㎛. Visual observation indicated that the PVA fibers mitigated the cracking and/or spalling of the specimens upon exposure to 800℃.

자착식 부틸고무시트에 다발형 유리섬유직포를 적층한 비노출방수공법에 관한 연구 (An Study on the Non-Exposure Waterproofing Method Laminated Twist Glass Fiber Mesh on Self Adhesion Butyl Rubber Sheet)

  • 방명진;박진상;강효진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.133-136
    • /
    • 2007
  • It has been applied the self adhesion waterproofing sheet which is developed from exist asphalt waterproofing sheet by heat and torch in domestic construction field. However, the problem of waterproofing have constantly happened due to air pocket condition and defect of joint part in waterproofing construction. Therefore, in this study, we would like to analyze the field application as testing in side of materials and construction method of self adhesion butyl rubber sheet and study of the materials performance.

  • PDF

고성능 RC 기둥의 재하가열시험에 의한 내화 특성 (Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test)

  • 김경민;김기훈;황인성;이재삼;이성연;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.57-60
    • /
    • 2005
  • This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

  • PDF

Ceramic 섬유의 강도 평가에 대한 Weibll 이론의 적용 (Application of Weifull강s Theory to Evaluation of Strength for Ceramic Fibers)

  • 이지환;김현수;한상훈
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1043-1049
    • /
    • 1990
  • In this work, strength of ceramic fibers and monofilament composites were evaluated on the basis of Weibull's theory. The fibers used were β-SiC and γ-Al2O3 monofilament composites was fabricated by coating Al on the fiber surface by the use of vacuum evaporation method. Average tensile strength of ceramic fibers showed the tendency to linearly decrease with increasing gauge length. Also, Weibull moduli of ceramic fibers were decreased with increasing gauge length, Weibull modulus of β-SiC was 3.5 for 6-50mm, 2.8 for 100-200mm. Weibull modulus of γ-Al2O3 was 6.5 for 20-50mm, 6 for 100mm. Fibers in monofilament retained their original as-produced strength to exposure temperature of 400℃. However, tensile strength of both monofilament composites approved to remarkably degrade due to interfacial reaction-induced flaws on the fiber surface after thermal exposure of 600℃. In this case, Weibull modulus of monofilament composites was 2.7 for β-SiC and 5.2 for γ-Al2O3 respectively.

  • PDF

일광노출에 의한 천연염직물의 색상변화에 관한 연구 (Color Changes of Natural-Dyed Fabrics under Sunlight)

  • 박명자;이연희;윤양노
    • 한국의상디자인학회지
    • /
    • 제6권3호
    • /
    • pp.45-53
    • /
    • 2004
  • Natural dyes have poor colorfastness as a result of the exposure of the dyed fabric to sunlight encountered during the display or wearing. As colors on fabrics fade excessively under sunlight, it is a problem to infer and restore the historic textiles with natural-dyed fabrics to original colors. The object of this study is to analyse the factors affected to color change under light. In experimental, fifteen natural dyes were dyed by the Korean traditional dyeing methods onto natural fiber fabrics: cotton, silk, ramie, and flex. Total 49 dyed fabrics in combination with dyes and fibers were used for the specimen. The Weather-O-meter was used for evaluating the effects of exposure to light for 2.5 to 450 hours. The process of color changes in the CIEL *A*B* color-order system to the exposure time were determined by spectrophotometer at 10$^{\circ}$ observer. Sunlight exposure caused significant changes in the color of natural-dyed fabrics. The degree and nature of color changes on the fabrics were dependent on the combination of fiber and the type of dye used. The groups of violet(Lithospermum erythrorhizon Sieb.et Zucc.) and black color(Ailanthus altissima Swingle, Phus trichocarpa Miq) yielded excellent colorfastness to light. The group of indigo blue color(Polygonum tinctorium Lour.) was also very resistant to fading in both exposure except silk. Whereas the dye groups of Red, Yellow, Orange, Brown colors indicated greatest changes in fading, particularly Carthamus tinctorius L.

  • PDF

Fire resistance evaluation of fiber-reinforced cement composites using cellulose nanocrystals

  • Lee, Hyung-Joo;Kim, Seung-Ki;Lee, Heon-Seok;Kang, Yong-Hak;Kim, Woosuk;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.311-320
    • /
    • 2019
  • In this study, the effect of cellulose nanocrystals (CNCs) on the fire resistance properties of fiber-reinforced cement composites was investigated. The main variables were CNCs content (0.4, 0.8 and 1.2vol.% compared with cement), steel fiber ratio, and exposure temperature (100, 200, 400, 600 and 800℃). The fire resistance properties, i.e., residual compressive strength, flexural strength, and porosity, were evaluated in relation with the exposure temperature of the specimens. The CNCs suspensions were prepared to composited dispersion method of magnetic stirring and ultra-sonication. CNCs are effective for increasing the compressive strength at high temperatures but CNCs do not seem to have a significant effect on flexural reinforcement. Porosity test result showed CNCs reduce the non-hydration area inside the cement and promote hydration.

폴리우레아 방수재의 탄소섬유함량에 따른 내열성능 변화추이 연구 (A Study on the Thermal Performance change due to amount of Carbon Fiber in Poly-Urea Waterproofing Material)

  • 박완구;박진상;최수영;김동범;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.126-127
    • /
    • 2017
  • This study investigates the effect of improving the heat resistance performance when carbon fiber is mixed in the polyurea coating material. A tensile strength test method was carried out with the carbon fiber mixed polyurea specimens at an interval of 7, 14, and 21 days after heat treatment at 140±2℃. The test results showed that there was a significant decrease in the tensile strength performance. While the elongation and tensile performance decreased greatly, it was confirmed nevertheless the overall performance was maintained. This study proposes that mixing carbon fiber to the polyurea resin can effectively secure long-term heat resistance, thereby solving the problem of deterioration of physical properties caused by exposure to ultraviolet rays.

  • PDF

석면과 건강에 대한 이슈 (Critical Issues on Health Risk of Asbestos)

  • 윤충식
    • 한국환경보건학회지
    • /
    • 제35권5호
    • /
    • pp.426-432
    • /
    • 2009
  • Asbestos is a commercial term of natural occurring silicated minerals and forms long, thin fibers. Chrysotile, the serpentine asbestos, accounts for most use in commercial use. Asbestos is well known health hazard material and it is proved that inhalation of asbestos fibers leads to increased risk of developing several diseases such as lung cancer, mesothelioma, asbestosis. In these days, people most at risk for exposure are maintenance and construction workers and general citizens who are working on and close to the work area at which asbestos containing material is disturbing. Non asbestiform, though its chemical composition is same with regulated asbestos, is known to be less hazardous than asbestiform. Exposure guideline, 0.01 f/ml, is not safe level in terms of health risk. It is reasonable to take preventable action when asbestos is suspicious. In Korea, it is necessary to clarify the concept between hazard and risk, to differentiate asbestiform from non asbestiform, to make regulations for compensation for asbestos related patients, to manage future exposure for general citizens.