• Title/Summary/Keyword: Fiber Level

Search Result 1,365, Processing Time 0.029 seconds

Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis (섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.

P-value significance level test for high-performance steel fiber concrete (HPSFC)

  • Abubakar, Abdulhameed U.;Akcaoglu, Tulin;Marar, Khaled
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.485-493
    • /
    • 2018
  • Statistical analysis has found useful application in the design of experiments (DOE) especially optimization of concrete ingredients however, to be able to apply the concept properly using computer aided applications there has to be an upper and lower limits of responses fed to the system. In this study, the production of high-performance steel fiber concrete (HPSFC) at five different fiber addition levels by volume with two aspect ratios of 60 and 83 were studied under two curing methods completely dry cured (DC) and moist cured (MC) conditions. In other words, this study was carried out for those limits based on material properties available in North Cyprus. Specimens utilized were cubes 100 mm size casted and cured for 28 days and tested for compressive strength. Minitab 18 statistical software was utilized for the analysis of results at a 5 per cent level of significance. Experimentally, it was observed that, there was fluctuation in compressive strength results for the two aspect ratios and curing regimes. On the other hand P-value hypothesis evaluation of the response showed that at the stated level of significance, there was a statistically significant difference between dry and moist curing conditions. Upper and lower limit values were proposed for the response to be utilized in DOE for future studies based on these material properties. It was also suggested that for a narrow confidence interval and accuracy of the system, future study should increase the sample size.

Influence of fat levels and types of dietary fiber on lipid metabolism of rats (식이중 지방 수준과 Fiber 종류가 흰쥐의 지방대사에 미치는 영향)

  • 윤홍재
    • Journal of the Korean Home Economics Association
    • /
    • v.23 no.2
    • /
    • pp.45-53
    • /
    • 1985
  • The influence of fat level and dietary fiber on serum and liver lipid concentration of the rat was investigated. Groups of rats were fed respectively 3%, 5%, 20% fat containing and free fiber diet until 5th week. From 5th week to 9th week high fat diet groups of rates were devided high fat diet group, high fat pectin supplemented diet group and high fat celulose supplemented diet group. Pectin and cellulose at 10% was supplemented to high fat diets. After rats were fed for 9 weeks, all rats were sacrificed to collect the liver and blood samples by heart puncture. Serum and liver lipids were determined on all rats and compared the histochemical lipid staining method with the biochemical analysis of serum and liver lipids. A high fat diet caused increased level of the total lipids, total cholesterol and free cholesterol contents in the liver and the serum. Rats fed pectin reduced body weight, werum lipid and liver lipid but cellulose had no effect to reduce serum and liver lipid concentration. These results indicate that dietary fat level led to changes in the lipid metabolism of rats and that pectin was more effective in lowering serum and liver lipid than cellulose.

  • PDF

Studies on the variation of diet fiber content according to pearling ratio of barley (보리의 도정율에 따른 식이섬유 함량 변이에 관한 연구)

  • 조미자
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.1
    • /
    • pp.181-186
    • /
    • 1995
  • This study was carried out to know the proper pearling ratio for maximum utilizatio of barley diet fiber, especially bata-glucan. Beta-glucan content were 2.35%, 2.72% and 3.24% in pearling ratio of 75%, 70% and 65%, respectively, which means the lower of pearling ratio, the more chance for use of beta-glucan. The embryo was completely removed from barley grain in 65% pearling but it was partially removed or not removed in pearling ratio of 70% and 75%, respectively. Total diet fiber content was higher at 75% pearling ratio while beta-glucan content was the lowest. The higher level of total diet fiber in lower pearling ratio was due to relatively higher content of insoluble diet fiber. The difference of soluble fiber due to pearling ratio was negligible diet fiber. The difference of soluble fiber due to pearling ratio was negligible, however, bata-glucan content was higher in higher pearling ratio. The results implied that it is better way to lowering perling ratio for miximum use of bata-glucan in barley.

  • PDF

Development of Ultrasonic Active Fiber Sensor for Structural Health Monitoring (구조물 안전진단을 위한 초음파능동형광섬유 센서의 개발)

  • Lim, Seung-Hyun;Lee, Jung-Ryul;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.747-752
    • /
    • 2008
  • Fiber-guided sensor system using a generator and a receiver can detect the amplitude of load or pressure. However, this type of sensor can show some difficulties in detecting the location of damages and pressure loadings. To overcome this weakness of this type, the ultrasonic active fiber sensor, which has an integrated ultrasonic generator and sensing part, was developed in this study. By using this sensor system, the location of mechanical loads can be exactly detected. Moreover, the ultrasonic active fiber sensor is more cost-effective than an ultrasonic fiber sensor using two piezoelectric transducers which are used as a generator and a receiver, respectively. Two applications of the ultrasonic active fiber sensor are demonstrated: cure monitoring of lead and measurement of liquid level. Present results showed that the active fiber sensor can be applied for various environmental sensing.

  • PDF

A Study on Fatigue Behaviors of RC Beams Strengthened with Carbon Fiber Sheets (CFS로 보강된 RC보의 피로거동에 관한 연구)

  • Park, Jeong-Yong;Cheung, Jin-Hwan;Kim, Seong-Do;Cho, Baik-Soon;Jang, Jun-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.35-38
    • /
    • 2005
  • Carbon fiber sheets are widely used for strengthening the deteriorated RC structures. However most studies on the strengthening method of RC structures with carbon fiber sheets are concerning static problems. The purpose of this experimental study is to present the basic data on fatigue behaviors of. RC beams strengthened with carbon fiber sheets. The experimental parameters of this study are ; 1) the existence of U-shaped carbon fiber sheets at the ends for anchoring, 2) the number of carbon fiber sheet layers in strengthening the RC beams, 3) the load levels of $60\%\~90\%$ of the static bending moment strength, which is obtained form the static tests. Experimental results are estimated from the relationships of load level, displacement, number of repeated load and released energy. It is concluded that U-shaped carbon fiber sheets for end anchoring is very effective and the beams strengthened with one layer of carbon fiber sheet have longer fatigue life than that with three layers.

  • PDF

Mechanical characteristics of Macro-Fiber Reinforced Concrete Pavement (매크로 섬유로 보강된 콘크리트 포장의 역학적 특성)

  • Choi, Sung-Yong;Jung, Woo-Tai;Park, Jong-Sup
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.171-174
    • /
    • 2009
  • This study analyzes the change of the basic characteristics of pavement concrete according to the reinforcement of macro-fiber and the results of the study can be summarized as follows. In the case of the compressive strength of the concrete, the fiber reinforced pavement concrete shows a small decreasing level compared to the basic mixing of pavement concrete (hereafter referred as 'Plain') based on the aging of 28 days. In particular, the polypropylene fiber made in Korea represents a decrease in the strength about 12% compared with that of the Plain. In the case of the tensile strength, it shows certain improvements in the tensile performance compared with that of the Plain. In particular, in the case of the polyvinyl alcohol fiber that shows the largest improvement in tensile performance, it shows an increase in its strength about 21%. In the case of the bending strength, there are no improvements in its strength in the fiber reinforced concrete compared to that of the Plain.

  • PDF

Development of submersion sensors using multi-mode fibers spliced with a fiber Bragg grating (다중모드 광섬유 융착형 침수 감지 센서 개발)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun;Shim, Joon-Hwan;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.925-931
    • /
    • 2009
  • This paper reports a preliminary experimental investigation and characterization of an optical fiber-based submersion sensor system for applications in water flooding and leakage. The sensor system comprises a multi-mode fiber spliced with fiber Bragg grating and an intensity-based interrogator. Submersion tests were conducted in water-air and Glycerin-air environments. By the refractive index of the fiber-probe surrounding materials, the reflectance and the detecting power level is determined. When the probe is dipped into the water, the optical output power dramatically decreases from -7.5dBm to -17.5dBm. But, the center of Bragg wavelength is not affected in spite of external material changes. Temporal response characteristics of the sensor system is investigated to verify the real-time reaction. When the probe is immersed into the liquid, there is no transition time.

Modified Micro-Mechanical Fiber Bridging Model for Crack Plane of Fiber Rreinforced Cementitious Composite (섬유보강 복합체의 균열면 해석을 위한 수정 미세역학 모델)

  • Shin, Kyung-Joon;Park, Jong-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.365-368
    • /
    • 2006
  • In this paper, the post cracking stress-crack width relationship of the composite is studied from a micromechanics points of view. Cook-Gordon debonding effect is studied by more refined method with considering of chemical friction of fiber interface. As a result, fiber with pre-debonding length retards stress development and shows more wide crack width for the same force level. longer pre-debonding length and lower pre-debonding bond strength results in lower full-debonding force, but same crack width.

  • PDF

Direct Numerical Simulation of Active Fiber Composite (능동 섬유 복합재의 직접적 수치 모사)

  • 백승훈;김승조
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.5-9
    • /
    • 2003
  • Stress and deflection of Active Fiber Composite(AFC) embedded and/or attached composite structures are numerically investigated at the constituent level by the Direct Numerical Simulation(DNS). The DNS approach which models and simulates the fiber and matrix directly using 3D finite elements need to be solved by efficient way. To handle this large scale problem, parallel program for solving piezoelectric behavior was developed and run on the parallel computing environment. Also, the stress result from DNS approach is compared with that from uniform field model.

  • PDF