• Title/Summary/Keyword: Femoral prosthesis

Search Result 33, Processing Time 0.036 seconds

Adaptive Postural Control for Trans-Femoral Prostheses Based on Neural Networks and EMG Signals

  • Lee Ju-Won;Lee Gun-Ki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.37-44
    • /
    • 2005
  • Gait control capacity for most trans-femoral prostheses is significantly different from that of a normal person, and training is required for a long period of time in order for a patient to walk properly. People become easily tired when wearing a prosthesis or orthosis for a long period typically because the gait angle cannot be smoothly adjusted during wearing. Therefore, to improve the gait control problems of a trans-femoral prosthesis, the proper gait angle is estimated through surface EMG(electromyogram) signals on a normal leg, then the gait posture which the trans-femoral prosthesis should take is calculated in the neural network, which learns the gait kinetics on the basis of the normal leg's gait angle. Based on this predicted angle, a postural control method is proposed and tested adaptively following the patient's gait habit based on the predicted angle. In this study, the gait angle prediction showed accuracy of over $97\%$, and the posture control capacity of over $90\%$.

Management of Severe Bone Defects in Femoral Revision following Total Hip Arthroplasty

  • Yicheng Li;Li Cao
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.101-107
    • /
    • 2024
  • Treatment of femoral bone defects continues to be a challenge in revision total hip arthroplasty (THA); therefore, meticulous preoperative evaluation of patients and surgical planning are required. This review provides a concise synopsis of the etiology, classification, treatment strategy, and prosthesis selection in relation to femoral bone loss in revision THA. A search of literature was conducted for identification of research articles related to classification of bone loss, management of femoral revision, and comparison of different types of stems. Findings of a thorough review of the included articles were as follows: (1) the Paprosky classification system is used most often when defining femoral bone loss, (2) a primary-length fully coated monoblock femoral component is recommended for treatment of types I or II bone defects, (3) use of an extensively porous-coated stem and a modular fluted tapered stem is recommended for management of types III or IV bone defects, and (4) use of an impaction grafting technique is another option for improvement of bone stock, and allograft prosthesis composite and proximal femoral replacement can be applied by experienced surgeons, in selected cases, as a final salvage solution. Stems with a tapered design are gradually replacing components with a cylindrical design as the first choice for femoral revision; however, further confirmation regarding the advantages and disadvantages of modular and nonmodular stems will be required through conduct of higher-level comparative studies.

Duromedics Mitral Valve Leaflet Escape (Duromedics 승모판막의 판엽파손)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.750-755
    • /
    • 1992
  • We report a case of leaflet embolization of central leaflet fracture a 31mm mitral Edw-ards-Duromedics prosthesis. A leaflet was fractured to two segments, a larger one embolized to right common iliac artery and a smaller one to left femoral artery, respectively. Patient was reoperated with 29mm mitral Carbomedics prosthesis and incidentally found of smaller segment in left femoral artery at cannulation site. The embolectomy was done 15 days after cardiac operation through midline abdominal incision, Leaflet escape of a mitral Edward-Duromedics prosthesis is a rare, potentially curable mode of valve failure. After mechanical valve replacement, unexplained heart failure and acute pulmonary edema, mechanical valve failure should be suspected. Correct interpretation of clinical signs, symptoms and fluroscopy should allow early diagnosis of leaflet escape and prompt surgical therapy.

  • PDF

Biomechanical characteristics of the distal filling effects in cementless femoral stem (무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성)

  • Park, Sang-eok;Park, Jae-Won;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

A Case of Surgical Treatment of the Abdominal Aortic Graft Infection with Bilateral Superficial Femoral Vein (양 표재성대퇴정맥을 이용한 복부 인조혈관 감염증 치험 1예)

  • 우종수;방정희;조광조
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.880-883
    • /
    • 2004
  • The graft infection within the abdomen is a notorious condition, which usually develops serious complications of anastomotic rupture or distal embolism that ended in death. There has been many controversies in the treatment of an aortobiiliac graft infection and varying results have been reported. The authors treated a case of aortobiiliac graft infection after abdominal aortic aneurysm surgery. The operation was performed with re-aortobiiliac bypass using bilateral superficial femoral veins. The result was successful.

Numerical simulation of the total hip prosthesis under static and dynamic loading (for three activities)

  • Mohammed El Sallah Zagane;Abdelmadjid Moulgada;Murat Yaylaci;Sahli Abderahmen;Mehmet Emin Ozdemir;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.635-645
    • /
    • 2023
  • This study aims to simulate the mechanical behavior of the total prosthesis model of Charnley (CMK3) by the 3D finite element method and to determine the state of the stresses in the femoral components (prosthesis, cement, and bone). The components are subjected to a dynamic load due to three activities (normal walking, climbing stairs, and standing up a chair). Static loading is by selecting the maximum load for the same activities mentioned. The results show that the maximum stresses in the proximal part of the cement are very important. Moreover, new results obtained for different parameters were discussed in detail. It is understood that current research provides important lessons for the surgeon to contribute to the clinical diagnosis of durable implantations and a better understanding of the process of bone remodeling and bone prosthesis.

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.

A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM (무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구)

  • Kim, S.K.;Chae, S.W.;Choi, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF

Limb Salvage Surgery after Removal of Infected Tumor Prosthesis with Equalization of Leg Length (감염된 종양 대치물 제거와 하지 단축 보정 후 시행한 사지 구제술 - 증례 보고 -)

  • Kwon, Young-Ho;Kim, Jae-Do;Chung, So-Hak;Cho, Yool
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • In 1996, a nine-year-old girl was treated with recycling autograft after wide resection of the distal femoral osteosarcoma. The leg lengthening and revision with growing tumor prosthesis were performed due to limb leg discrepancy and epiphyseal problem. However, deep infection developed after operation, and a temporary spacer with cement and Ender nail was inserted. After infection was controlled completely, the final leg lengthening was performed with mono-external fixator for limb length discrepancy (10 cm). Lastly, Tumor prosthesis was reinserted to preserve the joint function.

  • PDF