• Title/Summary/Keyword: Femoral head

Search Result 172, Processing Time 0.024 seconds

New Approach in the Treatment of Intertrochanteric Fracture Using a Cephalomedullary Nail (골수정을 이용한 대퇴골 전자간 골절의 새로운 치료 경향)

  • Kim, Junyoung;Choi, Kihong;Yang, Kyu Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • A gamma nail has been used to treat intertrochanteric fractures since 1988. Although such cephalomedullary nails have mechanical advantages over extramedullary fixation devices, such as sliding hip screw, their beneficial effects on treating the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31-A1 and 31-A2 fractures are still controversial. During their 30-year history, many problems have been overcome, and new types of cephalomedullary nails have been introduced in clinical practice. New cephalomedullary nail systems facilitate nailing procedures and enhance the purchase capability of the femoral head by a lag screw. On the other hand, the failure rate still depends on the hands of the orthopedic surgeons. This review article focused on the basic principle of medial support and restoration of a medial buttress during the treatment of trochanteric fractures using a cephalomedullary nail.

A biceps-bicaudatus sartorius muscle: dissection of a variant with possible clinical implications

  • Konstantinos Natsis;Christos Koutserimpas;Trifon Totlis;George Triantafyllou;George Tsakotos;Katerina Al Nasraoui;Filippos Karageorgos;Maria Piagkou
    • Anatomy and Cell Biology
    • /
    • v.57 no.1
    • /
    • pp.143-146
    • /
    • 2024
  • The current cadaveric report describes an unusual morphology of the sartorius muscle (SM), the biceps-bicaudatus variant. The SM had two (lateral and medial) heads, with distinct tendinous origins from the anterior superior iliac spine. The lateral head was further split into a lateral and a medial bundle. The anterior cutaneous branch of the femoral nerve emerged between the origins of the lateral and medial heads. SM morphological variants are exceedingly uncommon, with only a few documented cases in the literature, and several terms used for their description. Although their rare occurrence, they may play an important role in the differential diagnosis of entrapment syndromes, in cases of neural compressions, such as meralgia paresthetica, while careful dissection during the superficial inter-nervous plane of the direct anterior hip approach is of utmost importance, to avoid adverse effects due to the altered SM morphology.

Dosimetric comparison for Prostate VMAT of weight and photon energy change (전립선 암 입체적세기변조방사선치료 시 체형 및 에너지 변화에 따른 선량 평가)

  • Jo, Guang Sub;Kim, Min Woo;Baek, Min Gyu;Chae, Jong Pyo;Ha, Se Min;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.17-25
    • /
    • 2018
  • Purpose : To compare the radiation doses of prostate cancer patients according to changes in abdominal body shape and energy during Volumetric modulated arc therapy(VMAT). Materials and Methods : Seven patients with prostate cancer were enrolled in this study. VMAT treatment plan was established at 6, 10, and 15 MV while changing from -2.0 cm to 2 cm by 0.5 cm. Conformal index(CI), homogeneous index(HI), $D_{max}$, $D_{95%}$, $D_{50%}$ and $D_{2%}$ of PTV were examined in order to evaluate the change of dose in the target organ according to body shape change. Normal organ of the femoral head, rectum and bladder was analyzed to evaluate dose changes. Results : The dose of $D_{max}$ 6 MV in PTV increased to 107.2 % in 1.0 cm body shape reduction, and 10 MV and 15 MV dose increased to 107.1 % and 107.0 % in 1.5 cm body reduction, respectively. The dose of $D_{50%}$ 6 MV in PTV decreased to 99.64 % in 1.0 cm body shape increase, and in 10 MV and 15 MV dose decreased to 99.79 % and 99.97 % in 1.5 cm body increase, respectively. In 2.0 cm body type increase, the dose was decreased to 99.30 % and 99.52 %, respectively. Doses for rectum and bladder gradually increased with decreasing weight, and dose decreased with decreasing weight. 6 MV, and $V_{70Gy}$ at 10 MV increased from 11.50 % to 12.76 % when the external shape decreased by 2.0 cm. The bladder $V_{70Gy}$ also increased from 14.0 % to 15.2 %. It was also shown that the dose increased as the body weight decreased in the femoral head. Conclusion : In the treatment of VMAT, dose distribution can be changed according to the change of abdominal shape. SSD and CBCT were used to decrease the body shape by more than 1cm or more than 1.0 cm at 6 MV and the body shape by more than 1.5 cm or more than 1.5 cm at 10 MV or 15 MV. It is considered that a new treatment plan should be established through re-simulation.

  • PDF

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

Feasibility of Mixed-Energy Partial Arc VMAT Plan with Avoidance Sector for Prostate Cancer (전립선암 방사선치료 시 회피 영역을 적용한 혼합 에너지 VMAT 치료 계획의 평가)

  • Hwang, Se Ha;NA, Kyoung Su;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.17-29
    • /
    • 2020
  • Purpose: The purpose of this work was to investigate the dosimetric impact of mixed energy partial arc technique on prostate cancer VMAT. Materials and Methods: This study involved prostate only patients planned with 70Gy in 30 fractions to the planning target volume (PTV). Femoral heads, Bladder and Rectum were considered as oragan at risk (OARs). For this study, mixed energy partial arcs (MEPA) were generated with gantry angle set to 180°~230°, 310°~50° for 6MV arc and 130°~50°, 310°~230° for 15MV arc. Each arc set the avoidance sector which is gantry angle 230°~310°, 50°~130° at first arc and 50°~310° at second arc. After that, two plans were summed and were analyzed the dosimetry parameter of each structure such as Maximum dose, Mean dose, D2%, Homogeneity index (HI) and Conformity Index (CI) for PTV and Maximum dose, Mean dose, V70Gy, V50Gy, V30Gy, and V20Gy for OARs and Monitor Unit (MU) with 6MV 1 ARC, 6MV, 10MV, 15MV 2 ARC plan. Results: In MEPA, the maximum dose, mean dose and D2% were lower than 6MV 1 ARC plan(p<0.0005). However, the average difference of maximum dose was 0.24%, 0.39%, 0.60% (p<0.450, 0.321, 0.139) higher than 6MV, 10MV, 15MV 2 ARC plan, respectively and D2% was 0.42%, 0.49%, 0.59% (p<0.073, 0.087, 0.033) higher than compared plans. The average difference of mean dose was 0.09% lower than 10MV 2 ARC plan, but it is 0.27%, 0.12% (p<0.184, 0.521) higher than 6MV 2 ARC, 15MV 2 ARC plan, respectively. HI was 0.064±0.006 which is the lowest value (p<0.005, 0.357, 0.273, 0.801) among the all plans. For CI, there was no significant differences which were 1.12±0.038 in MEPA, 1.12±0.036, 1.11±0.024, 1.11±0.030, 1.12±0.027 in 6MV 1 ARC, 6MV, 10MV, 15MV 2 ARC, respectively. MEPA produced significantly lower rectum dose. Especially, V70Gy, V50Gy, V30Gy, V20Gy were 3.40, 16.79, 37.86, 48.09 that were lower than other plans. For bladder dose, V30Gy, V20Gy were lower than other plans. However, the mean dose of both femoral head were 9.69±2.93, 9.88±2.5 which were 2.8Gy~3.28Gy higher than other plans. The mean MU of MEPA were 19.53% lower than 6MV 1 ARC, 5.7% lower than 10MV 2 ARC respectively. Conclusion: This study for prostate radiotherapy demonstrated that a choice of MEPA VMAT has the potential to minimize doses to OARs and improve homogeneity to PTV at the expense of a moderate increase in maximum and mean dose to the femoral heads.

Comparison of Beam Delivery Modes in Prostate Cancer Proton Therapy: A Treatment Planning Comparison Study (전립선암 환자 양성자치료 시 빔 전달방식에 따른 치료계획 비교)

  • Kim, Youn Young;Youm, Doo Seok;Jang, Yo Jong;Kang, Dong Yun;Park, Jeong Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.153-158
    • /
    • 2013
  • Purpose: After making two plans, the Double Scattering (DS) Mode and The Pencil Beam Scanning (PBS) Mode, of patients on early prostate cancer, we not only compare the dose conformity and the dose homogeneity by analyzing each DVH, CN and HI, but also evaluate normal structures's sparing effect on each mode. Materials and Methods: Planes about nine patients, who did proton therapy, on prostate cancer was setted using the Eclipse proton external beam planning system. The prescription dose, every $2.5 Gy{\times}28$ fractions=70 Gy, was delivered to the PTV. The CN and the HI were getted by anlazing each DVHs for the DS Plan and the PBS Plan. Also, normal structures' %volumes according to dose of the PBS are campared with those of the DS. Results: The average CN of the PTV is increase 16.63% from DS $0.68{\pm}0.07$ to PBS $0.79{\pm}0.01$, and the average IN of the PTV is decrease -22.66 % from DS $0.12{\pm}0.03$ to PBS $0.09{\pm}0.01$. The PBS has litter %Volumes of normal structures than the DS about every patient except Rectum. The average %Volume of Left Femoral Head receiving ${\geq}30$ Gy shows most high decreasing rate, -79.93%, from DS to PBS and the average %Volume of Rectum receiving ${\geq}70$ Gy shows most low decreasing rate, -3.03%, from DS to PBS. Conclusion: Therefore, the PBS is more effective achieving the dose conformity and the dose Homogeneity than DS, and better to reduce unnecessary dose arriving normal structures, especially the femoral heads.

  • PDF

Effect of pelvic adjustment on chronic low back pain and spino-pelvic parameters in middle-aged women (골반교정이 중년 여성의 만성요통과 척추골반지표에 미치는 영향)

  • Seo, Yun-Gyo;Kim, Jaehee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.347-355
    • /
    • 2017
  • The purpose of this study was to investigate the effects of pelvic adjustment on low back pain and spino-pelvic parameters in middle-aged women. Thirty-eight middle-aged women with chronic low back pain were randomly assigned to the pelvic adjustment (n = 20) oruntreated control (n = 18) group. Pelvic adjustment interventionswereperformed four times a week for 8 weeksin the former group. At baseline and after 8 weeks, the back pain and back function were evaluated using the visual analogue scale (VAS), Oswestry disability index (ODI), and back flexibility. Additionally, the spino-pelvic radiographic parameters and serum C-reactive protein (CRP) levels were assessed. After 8 weeks, the VAS, ODI, and back flexibility significantly improved in the pelvic adjustment group compared with the control group. It was found that the changes from baseline in the lumbar lordotic angle, sacral slope, pelvic crest unleveling, and femoral head height inequality were significantly greater in the pelvic adjustment group than in the control group. There were no significant changes in the pelvic incidence or serum CRP levels in either group. In conclusion, pelvic adjustment has beneficial effects on chronic low back pain and back function, suggesting that the effects of pelvic adjustment on back pain may at least in part result from changes in the spino-pelvic alignment.

The Preservation of Joint Function in Treatment of Giant Cell Tumor of Bone (거대세포종의 치료시 관절 기능의 보존)

  • Bae, Dae-Kyung;Han, Chung-Soo;Sun, Seung-Deok;Baek, Chang-Hee;Rhee, Jae-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.145-153
    • /
    • 1995
  • Giant cell tumor is most frequently found in juxtaarticular region, and difficult to treat because of local recurrence. Although primary resections reduce recurrence, the joint function will be markedly impaired. Techniques involving physical adjuncts(high speed burr and electric cauterization), acrylic cement or en bloc resection with VFG(vascularized fibular graft) have been employed to reduce local recurrence. From October 1984 to April 1994, twenty-nine patients diagnosed as giant cell tumor were treated at department of Orthopaedic Surgery, School of Medicine, Kyung Hee University. There were eleven men and 18 women, ranging in age from 17 to 52 years(mean: 34 years). The average follow-up period was four years and five months. The location of the lesion was around the knee in 15, distal radius in three, femoral head in three, and others in eight patients. Fifteen patients around the knee joint were treated with several modalities; curettage with bone graft in five, curettage with cement filling in three, curettage with bone graft and physical adjuncts in five, en bloc resection with VFG in one and en bloc resection with arthroplasty in one patient. The functional results, according to the Marshall's knee score, were excellent in one, good in two, and fair in two after the curettage with bone graft, good in three after the curettage with bone cement filling, excellent in one, good in four after the curettage with bone graft and physical adjuncts, and good in two after the en bloc resection with VFG or arthroplasty. Three patients had local recurrence among 15 patients with giant cell tumor around knee. Vascularized fibular graft around wrist joint provided good functional restoration without local recurrence in all three patients who had giant cell tumor in distal radius. Although there is no statistical significance, it seems that curettage with bone graft using physical adjuncts or acrylic cement reveals better results than simple curettage with bone graft. Excellent functional result were obtained without local recurrence by using vascularized fibular graft after en bloc resection.

  • PDF

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.