• 제목/요약/키워드: Feeder voltage

검색결과 141건 처리시간 0.022초

직류 급전선 증설에 따른 전압강하 최소화를 위한 균압 스페이서 개발 (The Development of Equalizing Spacer for Minimization of Voltage Drop according to DC Feeder Extension)

  • 이재봉;서일권;나연일;김재문
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.1013-1018
    • /
    • 2014
  • This paper described the development of equalizing spacer for minimization of voltage drop according to DC feeder extension. Power consumption is increased as shorter interval of train driving time and transportation capacity increase in urban subway. Therefore we investigated voltage drop of catenary at a point in case of traction driving of a train in parallel to the DC power supply system. Based on it's result, equalizing spacer is designed and fabrication to minimize the voltage drop in accordance with the power supply line arranged in three rows, and then its performance was confirmed that the stress distribution of main body and the distributed load are satisfied through the body structure modeling.

순환최소자승법을 이용한 직류도시철도 변전소의 가선전압변동 모델링 (Modelling Voltage Variation at DC Railway Traction Substation using Recursive Least Square Estimation)

  • 배창한
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.534-539
    • /
    • 2015
  • The DC overhead line voltage of an electric railway substation swings depending on the accelerating and regenerative-braking energy of trains, and it deteriorates the energy quality of the electric facility in the DC railway substation and restricts the powering and braking performance of subway trains. Recently, an energy storage system or a regenerative inverter has been introduced into railway traction substations to diminish both the variance of the overhead line voltage and the peak power consumption. In this study, the variance of the overhead line voltage in a DC railway substation is modelled by RC parallel circuits in each feeder, and the RC parameters are estimated using the recursive least mean square (RLMS) scheme. The forgetting factor values for the RLMS are selected using simulated annealing optimization, and the modelling scheme of the overhead line voltage variation is evaluated through raw data measured in a downtown railway substation.

초전도 한류기를 주변압기 접지선에 설치시 배전계통의 순간전압품질 분석 (Voltage Quality Analysis in Power Distribution System with Superconducting Fault Current Limiter at Grounding Line)

  • 문종필
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.159-163
    • /
    • 2013
  • In this paper, voltage quality improvement is analyzed in case of Superconducting Fault Current Limiter (SFCL) installed in grounding line of main transformer in power distribution system. First, a resistive-type SFCL model is used. Next, Korean power distribution system is modeled. Finally, when SFCL is installed in the starting point of feeder and grounding line of main transformer, voltage qualities are evaluated according to various fault locations and resistance values of SFCL using PSCAD/EMTDC. The voltage quality results in case of grounding line are compared with the voltage in case of feeder.

Feeder Loop Line Control for the Voltage Stabilization of Distribution Network with Distributed Generators

  • Jeong, Bong-Sang;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2014
  • When renewable sources are connected to the distribution network in the form of a distributed generators(DGs), the effect of intermittent output appears as voltage fluctuation. The surplus power at the consumer ends results in the reverse power flow to the distribution network. This reverse power flow causes several problems to the distribution network such as overvoltage. Application of the reactive power control equipment and power flow control by means of BTB inverter have been suggested as the general solutions to overcome the overvoltage, but they are not economically feasible since they require high cost devices. Herein, we suggest the feeder loop line switch control method to solve the problem.

휴리스틱 탐색전략을 이용한 배전계통 계획의 급전선 최적 경로 선정 (Optimal Feeder Routing for Distribution System Planning Using a Heuristic Strategy)

  • 최남진;김병섭;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권11호
    • /
    • pp.566-574
    • /
    • 2000
  • This paper propose a heuristic algorithm based on the Branch-Exchange (BE) method to solve Optimal feeder Routing(OFR) problem for the distribution system planning. The cost function of the OFR problem is consisted of the investment cost representing the feeder installation and the system operation cost representing the system power loss. We propose a properly designed heuristic strategy, which can handle the horizon-year expansion planning problem of power distribution network. We also used the loop selection method which can define the maximum loss reduction in the network to reduce calculation time, and proposed a new index of power loss which is designed to estimate the power loss reduction in the BE. The proposed index, can be considered with both sides, the low voltage side and voltage side branch connected with tie one. The performances of the proposed algorithms and loss index were shown with 32, 69 example bus system.

  • PDF

전용통신선을 이용한 배전선로 자동운전과 저압배전선을 이용한 원격검침 (Feeder Automation using the communication cable and Automatic Meter Reading using the low voltage distribution line)

  • 조남훈;하복남;윤일환;장완성;김종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.680-682
    • /
    • 1996
  • Korea Distribution Automation System(KODAS) has been designed and implemented for feeder automation using the paircable as communication media. And we bave been developed the telemetering system using the low voltage line. Kepco have been constructed approximately 60% of the Cable TV(CATV) networks in large city in Korea since 1995, so we have been researching the feeder automation based on CATV networks also. We will contruct the system using its in the area with of cable-TV networks and paircable line in the other area for communication media in future.

  • PDF

연료전지 시스템을 이용한 전기철도 급전계통 전압강하 보상 (The Voltage Drop Compensation of Electric Railway Feeding system using a Fuelcell System)

  • 김재문
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.342-348
    • /
    • 2015
  • In this paper, fuel cell power generation system that is being studied in recent railway field was applied to compensate for the voltage drop due to the load as driving electric vehicle. PSIM simulation program is to be used to implement the modeling of the electric railway for AC AT feeder system. For it, It was applied to the product-type single-phase PLL algorithm, step-down converter is controlled as power so as to have the fuelcell generation system. Based on it's result, a reactive power due to the catenary impedance in accordance with the current flowing is compensated as linked with fuelcell generation system which supplied the current to the power supply grid. and then its performance was confirmed that voltage compensation effect obtained at SubStation (SS), SubSectioning Post (SSP), Sectioning Post (SP).

배전시스템에 전지전력저장시스템의 적용에 관한 연구 (A Study on Application of BESS at Distribution System)

  • 김영성;문선호;추동욱;김응상;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.867-870
    • /
    • 1997
  • This paper presents application of battery energy storage system(BESS) for interconnection with power distribution system. We configured interconnection model using PSCAD/EMTDC program. The simulation for voltage regulation on BESS interconnection with power distribution analyzes transient voltage variation, steady state voltage variation, and voltage of reverse power flow at interconnected feeder and nearby feeder.

  • PDF

코호넬 신경회로망을 이용한 배전시스템의 전압/무효전력 제어게 관한 연구 (A Study on the Voltage/Var Control of Distribution System Using Kohonen Neural Network)

  • 김광원;김종일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.329-331
    • /
    • 1998
  • This paper presents a modified Learning Vector Quantization rule to control shunt capacitor banks and feeder voltage regulators in electric distribution systems with Kohonen Neural Network(KNN). The objective of the KNN is on-line decision of the optimal state of shunt capacitor banks and feeder voltage regulators which minimize $I^{2}R$ losses of the distribution system while maintaining all the bus voltages within the limits. The KNN is tested on a distribution system with 30 buses, 5 on-off switchable capacitor banks and a nine tap line voltage regulator.

  • PDF

진동형 볼피더의 가진력 해석과 적용 (Analysis of Excitation Force and its Application in Vibratory Bowl Feeders)

  • 오석규;배강열
    • 한국기계가공학회지
    • /
    • 제19권11호
    • /
    • pp.70-77
    • /
    • 2020
  • Vibratory bowl feeders are widely utilized to align and feed the parts stacked inside the bowl of a feeder. The electro-magnetic force of the electromagnet in a bowl feeder generates the excitation force for the bowl to vibrate in both the horizontal and vertical directions to continuously feed the parts on the track. The feed rate of the part depends on the associated displacement in each direction during the vibration. Therefore, the excitation force induced by the electromagnet should be estimated in advance to ensure the suitable design of the bowl feeder. In this study, a theoretical solution was developed to calculate the electro-magnetic force of the electromagnet for a bowl feeder. Using the proposed solution, the electro-magnetic forces corresponding to a variation in the input parameters of the electromagnet, such as the voltage, frequency, and air gap, could be obtained. The force values obtained using the theoretical solution exhibited a satisfactory agreement with the results obtained using the finite element method, thereby demonstrating the validity of the approach. Subsequently, the bowl displacements were analyzed using the motion equation for the bowl feeder when the theoretically obtained excitation force were applied to vibrate the feeder. The correlation between the vertical displacements of the bowl and input parameters of the electromagnet could be obtained.