• Title/Summary/Keyword: Feedback oscillation

Search Result 144, Processing Time 0.022 seconds

Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger (전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가)

  • Kang, Hyung-Sub;Hong, Young-Pyo;Lee, In-Ho;Kim, Gi-Beum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.558-566
    • /
    • 2017
  • In this study, we developed an electron-emission OH radical generator for waste water treatment. The stability of the circuitry was ensured by implementing stable pulse waves with a MOSFET and reducing the momentary current rise. The OH radical generator uses a high-voltage and low-current discharger. The performance of the device was evaluated experimentally, which showed that it is possible to produce a stable and uniform pulse waveform for the drain current of the power MOSFET, which is connected to the input side of an AC multiplying converter through negative feedback circuitry with CR-snubber architecture. It was also possible to reduce the excitation current of the converter and improve the stability of the oscillation circuit. In addition, the generator can generate hydroxyl radicals stably. The bactericidal activities were also evaluated, and the germicidal power for E. coli, S. aureus, and S. flexneriwas improved by 99.9% or more after 60 minutes.

Endoplasmic Reticulum Ca2+ Store: Regulation of Ca2+ Release and Reuptake by Intracellular and Extracellular Ca2+ in Pancreatic Acinar Cells

  • Kang, Yun Kyung;Park, Myoung Kyu
    • Molecules and Cells
    • /
    • v.19 no.2
    • /
    • pp.268-278
    • /
    • 2005
  • We investigated the effect of cytosolic and extracellular $Ca^{2+}$ on $Ca^{2+}$ signals in pancreatic acinar cells by measuring $Ca^{2+}$ concentration in the cytosol($[Ca^{2+}]_c$) and in the lumen of the ER($[Ca^{2+}]_{Lu}$). To control buffers and dye in the cytosol, a patch-clamp microelectrode was employed. Acetylcholine released $Ca^{2+}$ mainly from the basolateral ER-rich part of the cell. The rate of $Ca^{2+}$ release from the ER was highly sensitive to the buffering of $[Ca^{2+}]_c$ whereas ER $Ca^{2+}$ refilling was enhanced by supplying free $Ca^{2+}$ to the cytosol with $[Ca^{2+}]_c$ clamped at resting levels with a patch pipette containing 10 mM BAPTA and 2 mM $Ca^{2+}$. Elevation of extracellular $Ca^{2+}$ to 10 mM from 1 mM raised resting $[Ca^{2+}]_c$ slightly and often generated $[Ca^{2+}]_c$ oscillations in single or clustered cells. Although pancreatic acinar cells are reported to have extracellular $Ca^{2+}$-sensing receptors linked to phospholipase C that mobilize $Ca^{2+}$ from the ER, exposure of cells to 10 mM $Ca^{2+}$ did not decrease $[Ca^{2+}]_{Lu}$ but rather raised it. From these findings we conclude that 1) ER $Ca^{2+}$ release is strictly regulated by feedback inhibition of $[Ca^{2+}]_c$, 2) ER $Ca^{2+}$ refilling is determined by the rate of $Ca^{2+}$ influx and occurs mainly in the tiny subplasmalemmal spaces, 3) extracellular $Ca^{2+}$-induced $[Ca^{2+}]_c$ oscillations appear to be triggered not by activation of extracellular $Ca^{2+}$-sensing receptors but by the ER sensitised by elevated $[Ca^{2+}]_c$ and $[Ca^{2+}]_{Lu}$.

Modeling and Simulation of the Cardiovascular System Using Baroreflex Control Model (압반사 제어모델을 이용한 심혈관 시스템의 모델링 및 시뮬레이션)

  • Choi, B.C.;Eom, S.H.;Nam, G.K.;Son, K.S.;Lee, Y.W.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.165-170
    • /
    • 1997
  • In this paper, we consider the aortic sinus baroreceptor, which is the most representative baroreceptors sensing the variance of pressure in the cardiovascular system(CVS), and propose heart activity control model to observe the effect of delay time in heart period and stroke volume under the regulation of baroreflex in arotic sinus. The proposed heart activity baroreflex regulation model contains CVS electric circuit sub-model, baroreflex regulation sub-model and time delay sub-model. In these models, applied electric circuit sub-model is researched by B.C.Choi and the baroreflex regulation sub-model transforms the input, the arotic pressure of CVS electric circuit sub-model, to outputs, heart period and stroke volume by mathematical nonlinear feedback. We constituted the time delay sub-model to observe sensitivity of heart activity baroreflex regulation model by using the variable value to represent the control signal transmission time from the output of baroreflex regulation model to efferent nerve through central nervous system. The simulation object of this model is to observe variability of the CVS by variable value in time delay sub-model. As simulation results, we observe three patterns of CVS variability by the time delay. First, if the time delay is over 2.5 sec, arotic pressure, stroke volume and heart rate is observed nonperiodically and irregularly. Second, if the time delay is from between 0.1 sec and 0.25 sec, the regular oscillation is observed. Finally, if time delay is under 0.1 sec, then heart rate and arotic pressure-heart rate trajectory is maintained in stable state.

  • PDF

Implementation of High Stable Phase-Locked Oscillator for X-Band Satellite Communication (X-Band 위성통신을 위한 고안정 위상 동기 발진기 구현)

  • Lim, Jin-Won;Joung, In-Ki;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.967-973
    • /
    • 2009
  • In this paper, X-band satellite communication oscillator of double phase locked is implemented by constructing a couple of phased-locked loop, and then we have analyzed the phase noise of designed PLL-DRO. The designed phase-locked oscillator is consist of series feedback DRO, frequency divider, phase detector, loop filter and programmable PLL-IC. By dividing oscillation frequency of 12.6 GHz into two frequencies, it exhibits output power of 15.32 dBm at 6.3 GHz. Phase noises of implemented oscillator are -81 dBc/Hz@100Hz, -100.86 dBc/Hz@1 kHz, -111.12 dBc/Hz@10 kHz, -116 dBc/Hz@100 kHz and -140.49 dBc/Hz@1 MHz respectively. These indicate excellent stable operation of oscillator and very good phase noise characteristics.

Pressure Control of Hydraulic Pump using SR Drive with Pressure Predict and Direct Torque Control Method (압력예측기법과 직접순시토크제어기법을 통한 유압펌프용 SRM의 압력제어구동)

  • Lee, Dong-Hee;Seok, Seung-Hun;Liang, Jianing;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Pressure control of hydraulic pump using SRM with pressure predictor and direct torque control method is presented in this paper. Nowadays, high efficiency and high performance motor drive is much interested in hydraulic pump system. But the hydraulic pump system has an inherent defect that its dynamic behavior causes by interaction between the sensor and hydraulic load. It will make low performance of whole system, even unstable and oscillatory. Proposed system integrates pressure predictor and direct instantaneous torque control (DITC). The pressure predictor includes Smith predictor, which is easy to improve unstable or long oscillation in traditional negative feedback control and popular PID control architectures. And DITC method can reduce inherent torque ripple of SRM, and develop smooth torque to load, which can increase stability and improve the torque response of SR drive. So high dynamic performance and stabilization can achieved proposed hydraulic system. At last, the proposed hydraulic system is verified by simulation and experimental results.

Phase Control Loop Design based on Second Order PLL Loop Filter for Solid Type High Q-factor Resonant Gyroscope (고체형 정밀 공진 자이로스코프를 위한 이차 PLL 루프필터 기반 위상제어루프 설계)

  • Park, Sang-Jun;Yong, Ki-Ryeok;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.6
    • /
    • pp.546-554
    • /
    • 2012
  • This paper suggests a design method of an improved phase control loop for tracking resonant frequency of solid type precision resonant gyroscope. In general, a low cost MEMS gyroscope adapts the automatic gain control loops by taking a velocity feedback configuration. This control technique for controlling the resonance amplitude shows a stable performance. But in terms of resonant frequency tracking, this technique shows an unreliable performance due to phase errors because the AGC method cannot provide an active phase control capability. For the resonance control loop design of a solid type precision resonant gyroscope, this paper presents a phase domain control loop based on linear PLL (Phase Locked Loop). In particular, phase control loop is exploited using a higher order PLL loop filter by extending the first order active PI (Proportion-Integral) filter. For the verification of the proposed loop design, a hemispherical resonant gyroscope is considered. Numerical simulation result demonstrates that the control loop shows a robust performance against initial resonant frequency gap between resonator and voltage control oscillator. Also it is verified that the designed loop achieves a stable oscillation even under the initial frequency gap condition of about 25 Hz, which amounts to about 1% of the natural frequency of a conventional resonant gyroscope.

Noise Characteristics of Readout Electronics for 64-Channel DROS Magnetocardiography System (64채널 DROS 심자도 시스템을 위한 검출 회로의 잡음 특성)

  • Kim J. M.;Kim K. D.;Lee Y. H.;Yu K. K.;Kim K. W.;Kwon H. C.;Sasada Ichiro
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.46-51
    • /
    • 2005
  • We have developed control electronics to operate flux-locked loop (FLL), and analog signal filters to process FLL outputs for 64-channel Double Relaxation Oscillation SQUID (DROS) magnetocardiography (MCG) system. Control electronics consisting of a preamplifier, an integrator, and a feedback, is compact and low-cost due to larger swing voltage and flux-to-voltage transfer coefficients of DROS than those of dc SQUIDs. Analog signal filter (ASF) serially chained with a high-pass filter having a cut-off frequency of 0.1 Hz, an amplifier having a gain of 100, a low-pass filter of 100 Hz, and a notch filter of 60 Hz makes FLL output suitable for MCG. The noise of a preamplifier in FLL control electronics is $7\;nV/{\surd}\;Hz$ at 1 Hz, $1.5\;nV/{\surd}\;Hz$ at 100 Hz that contributes $6\;fT/{\surd}\;Hz$ at 1 Hz, $1.3\;fT/{\surd}\;Hz$ at 100 Hz in readout electronics, and the noise of ASF electronics is $150\;{\mu}V/{\surd}\;Hz$ equivalent to $0.13\;fT/{\surd}\;Hz$ within the range of $1{\sim}100\;Hz$. When DROSs are connected to readout electronics inside a magnetically shielded room, the noise of 64-channel DROS system is $10\;fT/{\surd}\;Hz$ at 1 Hz, $5\;fT/{\surd}\;Hz$ at 100 Hz on the average, low enough to measure human MCG.

  • PDF

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

A Study on Robustness Improvement of the Semiconductor Transmitter and Receiver Module By the Bias Sequencing and Tuning the Switching Time (바이어스 시퀀스와 스위칭 타임 튜닝을 통한 반도체 송수신 모듈의 강건성 향상에 대한 연구)

  • Yoo, Woo-Sung;Keum, Jong-Ju;Kim, Do-Yeol;Han, Sung
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.251-259
    • /
    • 2016
  • This paper describes that how to enhance the robustness of semiconductor TRM(Transmitter and Receiver Module) through the bias sequencing and tuning the switching time. Previous circuit designs focused on improving the MDS(Minimum Detection Signal) performance. Because TRM has critical problem which transmission output signal leak into receiver by it's compact design. Under this condition, TRM was frequently broken down within the MTBF(Mean Time Between Failure). This study proposes the bias sequencing and tuning the switching time to improve above problem. At first, we collected major failure symptom and infer it's cause. Second, we demonstrated it's effect by derive the improvement method and apply it to our system. And finally we can convinced that the proposed method clear the frequent failure problem with its lack of isolation.

A Study on Adaptive Interference Canceller of Wireless Repeater for Wideband Code Division Multiple Access System (WCDMA시스템 무선 중계기의 적응간섭제거기에 관한 연구)

  • Han, Yong-Sik;Yang, Woon-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1321-1327
    • /
    • 2009
  • In this paper, as the mobile communication service is widely used and the demand for wireless repeaters is rapidly increasing because of the easiness of extending service areas. But a wireless repeater has a problem the oscillation due to feedback signal. We proposed a new hybrid interference canceller using the adaptive filter with CMA(Constant Modulus Algorithm)-Grouped LMS(Least Mean Square) algorithm in the adaptive interference canceller. The proposed interference canceller has better channel adaptive performance and a lower MSE(Mean Square Error) than conventional structure because it uses the cancellation method of Grouped LMS algorithm. The proposed detector uses the LMS algorithms with two different step size to reduce mean square error and to obtain fast convergence. This structure reduces the number of iterations for the same MSE performance and hardware complexity compared to conventional nonlinear interference canceller.