• Title/Summary/Keyword: Feedback Control System

Search Result 2,724, Processing Time 0.027 seconds

Adaptive Neural Control for Output-Constrained Pure-Feedback Systems (출력 제약된 Pure-Feedback 시스템의 적응 신경망 제어)

  • Kim, Bong Su;Yoo, Sung Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2014
  • This paper investigates an adaptive approximation design problem for the tracking control of output-constrained non-affine pure-feedback systems. To satisfy the desired performance without constraint violation, we employ a barrier Lyapunov function which grows to infinity whenever its argument approaches some limits. The main difficulty in dealing with pure-feedback systems considering output constraints is that the system has a non-affine appearance of the constrained variable to be used as a virtual control. To overcome this difficulty, the implicit function theorem and mean value theorem are exploited to assert the existence of the desired virtual and actual controls. The function approximation technique based on adaptive neural networks is used to estimate the desired control inputs. It is shown that all signals in the closed-loop system are uniformly ultimately bounded.

Nonlinear Excitation Control Design of Generator Based on Multi-objective Feedback

  • Chen, Dengyi;Li, Xiaocong;Liu, Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2187-2195
    • /
    • 2018
  • In order to realize the multi-objective control of single-input multi-output nonlinear differential algebraic system (NDAS) and to improve the dynamic characteristics and static accuracy, a design method of nonlinear control with multi-objective feedback (NCMOF) is proposed, the principium of this method to arrange system poles, as well as its nature to coordinate dynamic characteristics and static accuracy of the system are analyzed in detail. Through NCMOF design method, the multi-objective control of the system is transformed into linear space, and then it is effectively controlled under the nonlinear feedback control law, the problem to balance all control objectives caused by less input and more output of the system thus is solved. Applying NCMOF design method to generator excitation system, the nonlinear excitation control law with terminal voltage, active power and rotor speed as objective outputs is designed. Simulation results show that NCMOF can not only improve the dynamic characteristics of generator, but also damp the mechanical oscillation of a generator in transient process. Moreover, NCMOF can control the terminal voltage of the generator to the setting value with no static error under typical disturbances.

Chaos Synchronization Using Error Feedback Coupling

  • Khademian, Behzad;Haeri, Mohammad
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1632-1636
    • /
    • 2005
  • This paper presents synchronization of two identical Modified Chua's circuits using two strategies of error feedback coupling. In the first method the synchronization is achieved by linear unidirectional and in the second one by linear bidirectional error feedback coupling. Both proposed methods can make the states of the Modified Chua's circuits globally asymptotically synchronized. Numerical results are provided to show the effectiveness of the proposed approaches and to compare them together based on different criteria.

  • PDF

Input-Ouput Linearization and Control of Nunlinear System Using Recurrent Neural Networks (리커런트 신경 회로망을 이용한 비선형 시스템의 입출력 선형화 및 제어)

  • 이준섭;이홍기;심귀보
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.11a
    • /
    • pp.185-188
    • /
    • 1997
  • In this paper, we execute identification, linearization, and control of a nonlinear system using recurrent neural networks. In general nonlinear control system become complex because of nonlinearity and uncertainty. And though we compose nonlinear control system based on the model, it is difficult to get good control ability. So we identify the nonlinear control system using the recurrent neural networks and execute feedback linearization of identified model, In this process we choose the optional linear system, and the system which will have to be feedback linearized if trained to follow the linearity between input and output of the system we choose. We the feedback linearized system by applying standard linear control strategy and simulation. And we evaluate the effectiveness by comparing the result which is linearized theoretically.

  • PDF

Effect of feedback on PID controlled active structures under earthquake excitations

  • Nigdeli, Sinan Melih
    • Earthquakes and Structures
    • /
    • v.6 no.2
    • /
    • pp.217-235
    • /
    • 2014
  • In this paper, different feedback control strategies are presented for active seismic control using proportional-integral-derivative (PID) type controllers. The parameters of PID controller are found by using an numerical algorithm considering time delay, maximum allowed control force and time domain analyses of shear buildings under different earthquake excitations. The numerical algorithm scans combinations of different controller parameters such as proportional gain ($K_p$), integral time ($T_i$) and derivative time ($T_d$) in order to minimize a defined response of the structure. The controllers for displacement, velocity and acceleration feedback control strategies are tuned for structures with active control at the first story and all stories. The performance and robustness of different feedback controls on time and frequency responses of structures are evaluated. All feedback controls are generally robust for the changing properties of the structure, but acceleration feedback control is the best one for efficiency and stability of control system.

Integrated Displacement Feedback Control of a Self-levelling System (셀프레벨링 시스템을 위한 변위적분 피드백 제어 연구)

  • Lee, Young-Sup
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1317-1326
    • /
    • 2008
  • This paper presents a self.levelling system for a mass, which undergoes a severe acceleration, with integrated displacement feedback control. After a general description of such a system, theoretical analysis is investigated to design an active control device. The self-levelling system can be used to reduce the "quasi-static" deflection while isolating the "dynamic" vibration. A computer simulation model of 45 kg with two air spring mounts is considered to predict the performance of the control system. Important control parameters were acquired to meet the requirement of the system. The results showed the controller can reduce the displacement of the mass to the level of about 1/5 after control. Thus the self-levelling system can be applied usefully to reduce the displacement of a mass which experiences a high g dynamics.

Implementation of Remote Feedback Control System via Profibus-DP Network (Profibus-DP에서의 원격 피드백 제어 시스템 구축)

  • Lee, Kyung-Chang;Kang, Song;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.120-129
    • /
    • 2001
  • As many sensors and actuators are used in many automated systems, various industrial networks are adopted for real-time distributed control. In order to take advantages of the networking, however, the network implementation should be carefully designed to satisfy real-time requirements considering network delays. This paper presents the implementation of a remote feedback control system via Profibus-DP net work for real-time distributed control More specifically, the effect of the network delay on the control performance evaluated on Profibus-DP testbed. Also, the traditional PID gain tuning methods are used to demonstrate the feasibility of the remote feedback control.

  • PDF

Position Control of a 1/4 Car Suspension Simulator using a Feedback Linearization Controller (피드백 선형화 제어기를 사용한 1/4 차량 현가장치 시뮬레이터의 위치 제어)

  • Kim, T.H.;Lee, I.Y.
    • Journal of Drive and Control
    • /
    • v.9 no.3
    • /
    • pp.8-15
    • /
    • 2012
  • In the study, a control strategy using a feedback linearization compensator and a disturbance observer was suggested and applied to a hydraulic control system for a vehicle suspension simulator. Although the hydraulic system has comparatively big external loads composed by constant and varying loads, it is ascertained that excellent control performances are obtained with the suggested control strategy.

Robust Control of Pressure Control System Using Direct Drive Valve (DDV를 이용한 압력 제어시스템의 강인제어)

  • Lee Chang-Don;Park Sung-Hwan;Lee Jin-Kul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.12
    • /
    • pp.1077-1082
    • /
    • 2005
  • In this paper, it is proposed that the method for constituting pressure control system controlled by Direct Drive Valve (DDV). The DDV has a pressure-feedback-loop itself. It can eliminate non-linearity and uncertainty oi hydraulic system such as uncertain discharge coefficient and change of bulk-modulus. However, the internal feedback-loop can not compensate them perfectly. And fixed gain of the DDV's internal feedback-loop is not proper to apply it through wide pressure range. The steady state error and nonlinear characteristic of transient behaviour is observed in the experiment. So another controller is needed for the desirable performance of the system. To compose the controller, the pressure control system controlled by DDV is modeled mathematically and the parameters of the model are identified using signal-compression method. Then sliding mode controller is designed based on mathematical model. Desirable performance of the pressure control system controlled by DDV is obtained.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF