• 제목/요약/키워드: Feed Water Valve

검색결과 25건 처리시간 0.026초

한울 3호기 주급수 배관 용접부 육안검사 경험 (Experience in Visual Testing of the Main Feed Water Piping Weld for Hanul Unit 3)

  • 윤병식;문균영;김용식
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.74-78
    • /
    • 2015
  • Nuclear power plant steam generator that is one of the main component has several thousands of thin tubes. And the steam generator tube is subject to damage because of the severe operation conditions such as the high temperature and pressure. Therefore periodic inspections are conducted to ensure the integrity of steam generator component. Hanul unit 3 also has been inspected in accordance with in-service inspection program and is scheduled to be replaced for exceeding the plugging rate which was recommended by manufacturer. During the steam generator replacement activity, we found several clustered porosity on inner surface of main feed water pipe. Additionally crack-like indications were found at weld interface between base material and weld of main feed water pipe. This paper describes the field experience and visual testing results for inner surface of main feed water pipes. The destructive test result had shown that these indications were porosities which were caused by manufacturing process not by operation service.

한국표준원전 주급수 밸브의 파괴인성 평가 (Fracture Toughness Evaluation for Main Feed Water Valves of Korean Standard Nuclear Power Plant)

  • 윤지현;홍석민;이봉상
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.39-44
    • /
    • 2015
  • The fracture toughness of 2.25Cr-1Mo cast steel (SA217-WC9) samples which were taken from the check valves of feed water piping of Korean Standard Nuclear Power Plant(KSNPP) was measured by Master Curve method. The measured $T_0$ reference temperature of SA217-WC9 steel was $-30^{\circ}C$. The obtained $T_0$ was compared to the derived value from Charpy impact test data following to SINTEP procedure. The heat-to-heat variation in fracture toughness of SA217-WC9 steel was observed. It was found that the low toughness of a heat of SA217-WC9 steel was attributed to the coarse MnS inclusion originated by high sulfur content as the results of microanalyses.

상수도의 저용해성 액체 정량투입 방안 연구 (A Study on the Correct injection method for low dissolution liquid in the Water Treatment Plant)

  • 김진훈;박종호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.273-277
    • /
    • 2005
  • The large particles of suspended matter in raw water can be removed by allowing them to settle out in a presedimentation basin. But there are smaller particles in almost all surface water and some groundwater that will not settle out within a reasonable time without some help to accelerate the process, In the coagulation and flocculation processes, nonsettleable solids are converted into large and heavier settleable solids by physical-chemical changes broght about by adding and mixing coagulant chemicals into the raw water. The object of this research was to improve corrective injection method for low dissolution liquid in the water treatment plant. A sort of chemical feed equipment are diaphram pump, flow control in combined magnetic flowmeter md control valve, roto dipper wheel system and tube pump. Particularly low dissolution liquid (Calcium Hydroxide) put in a bit by feed equipment, tube pump is very useful method for corrective injection method in the water treatment plant.

  • PDF

양계 급수용 구면 피스톤 니플의 성능 평가 (Evaluation of Sphere Faced Type Piston Nipple for Water Feed of Poultry)

  • 김기선
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.961-967
    • /
    • 2007
  • 양계 농장의 자동화 시설 중 닭에 물을 공급하는 자동 급수 장치는 닭 사육을 위한 가장 중요한 시설중의 하나이다. 이 장치 부품 중 급수 니플은 닭이 직접 물을 먹는 장치이며 그 내부에 체크 밸브가 있어 물 공급 시에는 열리고 물을 먹지 않을 경우는 닫히게 된다. 니플의 종류는 피스톤 니플과 볼 니플로 나누워지며 볼 니플은 니플 스틱의 운동이 자유롭게 되어 낙수의 차단이 잘되는 장점이 있으나 복잡한 구조를 갔고 있는 단점이 있다. 이에 반하여 피스톤 니플은 구조가 간단한 장점이 있는 반면에 대부분 상하운동만 가능한 단점이 있다 최근에 이를 보완하기 위하여 피스톤 니플에 밸브 시트면을 구 형태로 제작하여 피스톤 형식이면서 자유로운 운동이 가능 하도록 한 구조(이하 : 구면 피스톤 니플)가 개발 되었다. 본 실험에서는 최근 관심을 갖게된 구면 피스톤 니플에 대한 성능 평가를 수행하였으며 그 결과를 국내외 기존 제품인 볼 니플 및 피스톤 니플과 성능을 실험적으로 비교 분석하였다. 그 결과 구면 피스톤 니플의 성능은 기존 피스톤 니플 보다는 좋은 결과를 얻었으며 볼 니플과는 유사한 성능임을 확인하였다.

  • PDF

급수밸브 내부의 유동경로 수치해석 (Numerical Analysis of Flow Path inside the Feedwater Valve)

  • 곽승현;원용휘
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.416-419
    • /
    • 2006
  • Numerical analysis is carried out to identify the wall thinning effect inside the feed water valve. The finite volume method is applied to make analysis for the viscous flows. The commercial cock FLUENT is used for the simulation and the GAMBIT for the grid generation. The RNG $\kappa-\varepsilon$ model is used for the turbulence and the tet-hybrid grid is applied for the modeling. The velocity vector, the pressure contour, the change of residual along the iteration number, and the dynamic head are predicted for the hydrodynamic investigation.

  • PDF

보일러 급수펌프용 1500lb 고차압 제어밸브 유량시험 및 수치해석에 관한 연구 (A Study on the Flow Coefficient Test and Numerical Analysis about 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump)

  • 이권일;장훈;이치우
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.541-547
    • /
    • 2022
  • Before making a prototype, we predicted the inlet/outlet differential pressure and flow coefficient, which are the most basic design data for the valve through the design and numerical analysis of the trim, which is the most important in the localization development of the 1500Ib high differential pressure control valve used for boiler feed water. As a result, the design value and the analysis value were found to be about 98% similar. The flow field within the fluid velocity of 23m/s to prevent cavitation was also found. The result of the numerical analysis on thermal stress due to the characteristics of valves exposed to high temperatures showed that it was found to be about 18% less than the allowable stress of the bolt fixing the trim. When all loads such as pressure, self-weight, and vibration are applied, however, it is judged to go beyond the currently calculated thermal stress, exceeding the allowable stress.

육상양식장용 자동 먹이 공급 시스템 개발에 관한 연구 (A study on the development of automatic feeding system in an inland aquafarm)

  • 오진석;조관준
    • 한국항해항만학회지
    • /
    • 제34권1호
    • /
    • pp.77-82
    • /
    • 2010
  • 오늘날 해안의 인구 증가와 산업화로 인하여 해안의 수질오염이 날로 증가하고 있으며, 이로 인한 생태계가 파괴됨으로써 수산물 양식업에 많은 문제를 발생시키고 있다. 이러한 문제를 해결하기 위해 해상 양식장이 육상 양식장으로 이동하고 있다. 본 논문은 육상 양식장에서의 자동 먹이 공급 시스템에 관하여 설명하고자 한다. 현재의 자동 먹이 공급 장치는 먹이양의 정확도가 떨어지고 먹이 공급 모터에 의해 먹이가 부서지는 단점을 지닌다. 그러나 제안하는 시스템은 현재의 시스템과 비교했을 때 로드 셀과 밸브의 조합을 사용하여 제어함으로써 높은 정확도를 가지고 먹이를 공급할 수 있으며, 먹이를 육상 양식 수조에 안전하게 공급할 수 있다. 실제 시스템을 통한 실험을 수행함으로써 모든 상황에서 육상 양식장 수조에 먹이를 공급할 수 있음을 입증한다.

초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계 (Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler)

  • 김연환;배용채;김재원;이두영;허해용
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

급수 배관계의 음향진동 현상 고찰 및 대책 (Mechanism Investigation and Measures on Acoustic Vibration Phenomena of Water Supply Piping)

  • 김연환;배용채;이두영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.470-475
    • /
    • 2012
  • The downstream piping system of the water supply system in a supercritical power plant is affected by the fluctuation pressure waves induced by accessing to the acoustic modes of the piping systems with the rotation and impeller passing pulsations of the feed water pump. There are the phenomena amplified at the same time in the range of 415 ~ 455Hz, 830 ~ 910Hz, 1245 ~ 1365Hz and 1660 ~ 1820Hz on the spectrums of the vibration, the sound pressure, and the pressure fluctuation waves.

  • PDF

KSR-III 추진제 탱크 압력 조절용 레귤레이터 개발 (The Development of Pressure Regulator of Propellant Tank for KSR-III)

  • 정영석;조기주;조인현;김용욱;오승협
    • 한국추진공학회지
    • /
    • 제6권4호
    • /
    • pp.47-58
    • /
    • 2002
  • 압력조절 레귤레이터는 KSR-III 추진제 탱크의 압력 조절용으로 개발하였다. KSR-III 가압 시스템은 가압 탱크, 압력조절용 레귤레이터, 추진제 탱크로 구성된 가장 기본적인 시스템이며 레귤레이터는 헬륨 탱크, 파이로밸브, 헬륨주입밸브와 더불어 가장 핵심적인 부품이다. 1차 시제품으로 기밀, 강도, 기본 성능을 만족하는 상세 설계를 완성하였고 2차 시제품으로 추진기관 종합수류시험을 수행하였다. 2차시험을 통해서 밸브의 용량(Cv)을 늘려야 할 필요성이 나타났다. 3차 시제품에 이를 개선하였으며 추진기관 종합 실추진제 시험과 연소시험을 통해 최종 검증하였다.