• Title/Summary/Keyword: Fault line

Search Result 1,138, Processing Time 0.027 seconds

Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP (EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석)

  • Jung, Chae-Kyun;Jang, Tai-In;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.

A study on the Heat Transfer Performance according to Ground Heat Exchanger Types (지중열교환기의 종류에 따른 열전달 성능에 관한 연구)

  • Hwang, SuckHo;Song, Doosam
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.75-80
    • /
    • 2010
  • Generally, ground-source heat pump (GSHP) systems have a higher performance than conventional air-source systems. However, the major fault of GSHP systems is their expensive boring costs. Therefore, it is important issue that to reduce initial cost and ensure stability of system through accurate prediction of the heat extraction and injection rates of the ground heat exchanger. Conventional analysis methods employed by line source theory are used to predict heat transfer rate between ground heat exchanger and soil. Shape of ground heat exchanger was simplified by equivalent diameter model, but these methods do not accurately reflect the heat transfer characteristics according to the heat exchanger geometry. In this study, a numerical model that combines a user subroutine module that calculates circulation water conditions in the ground heat exchanger and FEFLOW program which can simulate heat/moisture transfer in the soil, is developed. Heat transfer performance was evaluated for 3 different types ground heat exchanger(U-tube, Double U-tube, Coaxial).

Neural Network Application to the T/L Operation for Suppression of Short Circuit Capacity (고장용량 감소를 위한 송전선 개방 운용에 신경회로망 적용 연구)

  • Lee, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.26-30
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the methods for wuppressing the short circuit capacity. This paper presents the T/L switching operation by using the Hopfield neural network(HNN). The switching of T/L can make the line powers and the bus voltages deteriorated, as well as the fault current decreased. Such an insecure state should be avoided when the T/L is operated to be open. In this studies, the inequality constraints are formulated into the objective function to be incorporated with the HNN. Test results show that the convergence characteristics of HNN lead to the adequate solution of T/L switching.

  • PDF

An Analysis of Grounding Methods for Safety of Linemen in Distribution Line (배전선로 작업안전을 위한 최적접지 방법 평가)

  • Lee, H.S.;Choi, S.W.;Ryu, B.H.;Chang, S.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.477-479
    • /
    • 2000
  • This paper presents an analysis which compares the effectiveness of different temporary safety grounding methods on working overhead distribution system. The analysis studied direct energization at fault conditions with seven scenarios. The results show that the scenario, single point safety grounding on the working pole with brackets Pairs spaced 2 km apart on both side of a work site is safest grounding method. This can be used to evaluate lineman safety on a overhead distribution systems in Korea.

  • PDF

The result on field test of distribution automation in distribution test center (배전 실증시험장에서의 배전자동화 실증시험 결과)

  • Ha, Bok-Nam;Yoon, Tae-Sang;Jeong, Yeong-Ho;Cho, Nam-Hun;Lim, Seong-Il;Kang, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.182-184
    • /
    • 2000
  • There are several facilities in Kochang distribution test center such as artificial fault generator(AFG), new distribution automation system(NDAS), communication networks (wireless and optic), lumped constant circuit, switches for distribution automation, overhead and underground distribution line. We have been field testing on remote control, data acquisition. remote metering, feeder automation and so on for distribution automation using those equipment.

  • PDF

Analysis of transient state between Korea and Japan in Underground Transmission Cable System (국내외 지중송전시스템의 과도상태 해석)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Lee, D.I.;Jung, C.K.;Lee, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.462-464
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge between Korea and Japan on underground power cable systems. For analysis, find proper earthing resistance of neutral grounding system adopted in Japan. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

  • PDF

Design & Development of System Architecture for Wide Area Defense System (광역정전 Defense를 위한 System Architecture 설계 및 개발)

  • Kim, S.-Tae;Lee, Jeong-Hyun;Kim, Ji-Young;Lee, Dong-Chul;Moon, Young-Hwan;Kim, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.165-166
    • /
    • 2006
  • Recently, after Wide Area Outage of the North-Eastern United States occurred, many countries started to be concerned about WAMS (Wide Area Monitoring System), and Korean power system also experienced Wide Area outage according to typhoon Mae-Mi, and Haenam-Jeju HVDC line fault. Since it is too difficult to detect a symptom based on SCADA or EMS, a defense system of electric power infrastructure has required. In this research, the designed and developed system processes the time synchronized real time power system information based on GPS and shows the 2D/3D monitoring viewer using the phasor data and the results of three algorithms.

  • PDF

Factors Influencing Transient Stability in Network Connected to Wind Power Generation System (풍력발전시스템이 연계된 계통의 과도안정성에 영향을 미치는 요소)

  • Kim, Se-Ho;Oh, Sung-Bo;Ko, Seoung-Min;Ahn, Jae-Hyun;Lee, Soo-Mook;Jang, Si-Ho;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.535-536
    • /
    • 2006
  • This paper reports investigation into the factors that influence the transient behavior of the wind power generation system following network fault conditions. It is shown that the critical clearing time(CCT) can be affected by various factors contributed by the host network. Such factors include capacity of wind power, power factor, the length of the interfacing line, etc. This investigation is conducted en a simulated grid-connected wind farm using Digsilent Power Factory.

  • PDF

Analysis of 765kV Transmission Line Fault (765kV신태백#1T/L 고장에 따른 보호시스템 동작 분석)

  • Yoon, J.W.;Kim, B.J.;No, J.H.;Kim, J.Y.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.362-364
    • /
    • 2005
  • 전력계통이 대형화되고 복잡 고도화 되는 추세에 따라 전력계통운용에서 송전선로 보호시스템의 중요도가 매우 커지게 되었다. 이에 국내에 적용되기 시작한 765kV 전력계통망은 하위 전압계급 계통망에 미치는 영향이 커지게 되어 765kV 송전선로 보호시스템의 보호 신뢰도 향상은 전력계통을 안정적으로 운전하는 데 있어서 매우 중요한 요소가 되었다. 지난 2004년 11월에 신태백-신가평변전소간 765kV신태백T/L의 상업 운전이 시작되었고 그 상업운전 중 2005년 3월 낙뢰사고에 의한 765kV신태백T/L의 고장이 발생하였다. 이에 본 논문에서는 신태백T/L의 고장이 발생에 대한 보호시스템의 동작 상태를 분석한 사례에 대해서 기술하였다.

  • PDF

Road Boundary Detection on Highway with Searching Region of Interest on the Hough Transform Domain (Hough 변환된 영역의 관심 영역 검색 방법을 이용한 고속도로의 도로 윤곽선 검출)

  • Lin, Haiping;Bae, Jong-Min;Kim, Hyong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.297-299
    • /
    • 2006
  • Searching the region of interest on the Hough transform domain is done to determine the real road boundary on the high speed way. The mathematical morphology is employed to obtain the gradient image which is utilized in Hough transform. Many possible candidates of lines could appear on the ordinary road environment and simple selection of the strongest line segments likely to be fault boundary lines. To solve such problem, the search area for the candidates of the road boundary which is called the region of interest is limited on the Hough space. The effectiveness of the proposed algorithm has been shown with experimental results.

  • PDF