• 제목/요약/키워드: Fault line

검색결과 1,138건 처리시간 0.022초

실계통에서의 154kV HTS-FCL Bus-Tie 최적 적용방안에 관한 연구 (A Study on the Bus-Tie Application of 154kV HTS-FCL in Korean Power System)

  • 김종율;윤재영;이승열
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권5호
    • /
    • pp.226-233
    • /
    • 2005
  • As the power demand has been increasing, a fault current problem is becoming more serious in real power system. Various ways like bus-split operation, transmission line open operation, are used in Korean power system for solving the problem. In this time, superconducting FCL(Fault Current Limiter) has been developed as a vary attractive alternative since HTS(High Temperature Superconductivity) was discovered. Korea, a project developing superconducting FCL to apply to 154kV transmission system is proceeding. Therefore, a power system analysis for SFCL application to power system is necessary, This paper presents the determination of quenching resistance and the selection of optimal cites when 154kV HTS-FCL is applied to Korean power system.

직류전동기 구동 원심펌프-파이프 계통의 고장검출진단시스템: 등가관계 접근법 (Fault Detection and Isolation System for DC motor driven Centrifugal Pump-Pipe Systems: Parity Relation Approach)

  • 박태건;류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.819-821
    • /
    • 1998
  • This paper deals with a method or a residual generation for fault isolation in a centrifugal pump with a water circulation system, driven by a speed controlled dc motor. It is based on parity relations derived from the moving-average model of the system and is used to identify sensor faults and two possible brush and impeller faults, where the former is dealt with additive faults, while the latter characterized as discrepancies between the nominal and actual plant parameters of the system is modelled by multiplicative faults. We will represent the propagation of this uncertainty to the model matrices by the approximate handling of partial derivatives of polynomials. With multiplicative faults, the transformation matrix implemented in the residual generator are calculated on-line. The simulation studies demonstrate that small changes of the system can be detected and diagnosed by using the method.

  • PDF

신드롬 테스트가 용이한 대규모 MOSPLA의 설계 (Syndrome Testable Design for Large MOSPLA's)

  • ;임인칠
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.527-534
    • /
    • 1987
  • This paper proposes a new syndrome-testable design method for large MOSPLA's. In the conventional syndrome test method, the testing array circuit for testability is added but it has the defect that the circuit gives effect on the normal operation of the basic PLA circuit. Therefore, by adding the shift registers to the product lines of the basic MOSPLA's this defect is eliminated and the number of test patterns is decreased. In order to reduce the number of fault free syndromes to be predetermined, also, one output line, which is connected to all product lines is added. Therefore the number of output lines be observed is decreased. And the analytical method to compute fault free syndromes is presented. By unsing this method, the time and the effort to compute the syndromes are decreased.

  • PDF

Oscillation Frequency Estimation for Detecting Feedback Bridging Faults

  • Hashizume, Masaki;Inou, Nobuyuki;Yotsuyanagi, Hiroyuki;Tamesada, Takeomi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1980-1983
    • /
    • 2002
  • When a feedback bridging fault is activated in a circuit, logical oscillation may occur at a signal line. If the oscillation appears, the fault may not be detected by logic testing. In order to detect such bridging faults, output logic values of the circuit should be measured at higher frequency than frequency of the logical oscillation. In this paper, a method fur estimating the maximum frequency of logical oscillation is proposed to detect such bridging faults in a circuit by logic testing. Also, it is shown by some experiments that such bridging faults can be detected by measuring output logic values at the frequency obtained by the method.

  • PDF

PU법에 의한 DC 회로계산 및 실계통 데이터를 이용한 전압강하/고장계산 방법 (A Lecture Note on PU Method thru Calculation of a Simple DC Circuit and Voltage/Fault Analysis of Industrial Power Systems using Actual Data)

  • 이상중
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.45-54
    • /
    • 2014
  • This paper presents a lecture note of pu method for power system analysis. The author tries to help students in class better understand the fundamental of pu calculation using a very simple DC circuit. And a voltage drop calculation by pu method for a distribution system is given to help understand the importance of the vector reference in AC circuit analysis. A short current calculation by pu method for a power system with a generator, transformer and transmission line is also presented to show how pu calculation can be applied to real power systems, in which all the data are the ones currently being used by KEPCO and other industrial sites.

옥내 배전선로용 아크차단기 개발에 관한 연구 (A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line)

  • 곽동걸;최정규;박영직;김진환;손재현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF

PC 인터페이스에 의한 디지털 계전기 시험기 (A PC Based Tester for Digital Relay)

  • 박철원;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권11호
    • /
    • pp.536-541
    • /
    • 2000
  • Digital protective relay in power system play a prominent part. Simulators for the relay test were introduced in early 1980's. A number of open loop designs have been developed and recently, several developments of real-time simulators have been reported. But they are very high cost. And then they are difficult to apply for relay testing in small business. This paper presents the structure of low cost and performance of a new pc based tester for digital protective relay testing. The proposed tester was simulated of off-line with fault transient signals obtained from EMTP.

  • PDF

배전선로 고장징후 예지 시스템 개발에 관한 연구(I) (A Study for the Prediction Method of Fault Symptoms on Distribution Feeders(I))

  • 신정훈;김태원;박성택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1213-1216
    • /
    • 1998
  • This paper presents the result of a feasibility study for the prediction method of fault symptoms on 22.9kV distribution line. In this paper, real distribution data was collected and analyzed to isolate failure signatures or parameters which were distinct behaviors before and after failure incident. A new strategy of analysis-based (event-date concept) prediction algorithm for the distribution insulators and a developed model system were also discussed.

  • PDF

전력계통 안정화를 위한 퍼지 유계함수 추정을 이용한 슬라이딩 제어 (Stabilization of Power Systems with a Sliding Control Using Fuzzy Estimation of Bounding Function)

  • 박영환;박귀태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.875-879
    • /
    • 1998
  • A fault on the transmission line results in the variation of reactance and parametric uncertainties in the power system dynamics. In this case, we need a robust control to cope with these uncertainties. A sliding mode control, a sort of robust control, is known to be robust to parametric or state-dependent uncertainties if the bounding function of uncertain terms is determined a priori. However, in general, we can not readily determine the bounding function for the complex systems. Hence, in this paper we introduce a fuzzy system which can estimate the bounding function in relatively simple way. By the use of the proposed fuzzy system, determination of bounding function is made easier. We applied the proposed scheme to the stabilization of power system under the sudden fault on the transmission lines. The simulation result verifies the effectiveness of the scheme.

  • PDF

디지털 거리계전기의 Zone 설정에 관한 연구 (A Study on the Zone Setting of Digital Distance Relay)

  • 이재규;정창호;정병태;안복신;김석일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.946-948
    • /
    • 1998
  • The distance relay is very important for transmission line protection. A quadrilateral zone shape is used mainly for a modern digital distance relay. The shape of quadrilateral is vendor specific. At the stage of design, the shape is determined considering all possible types of faults and diverse configurations of system. Also this type relay must be designed to avoid the operation by a sound phase at single-Phase-to-ground fault, by a sound phase at two-phase-to-ground fault. The effect of a source impedance and a load impedance is another important factor to design. In this paper, a reliable zone shape which is appropriate for the KEPCO's transmission system is provided.

  • PDF