• Title/Summary/Keyword: Fault line

Search Result 1,139, Processing Time 0.025 seconds

Development of Feeder Automation Software Considering the Diversity Events of Distribution System (배전계통의 다양한 이벤트들을 고려한 선로자동화 소프트웨어 개발)

  • Ko, Yun-Seok;Kim, Yun-Jib;Bak, Young-Gu;Lee, Kee-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.307-309
    • /
    • 2002
  • This paper proposes an expert system, which is able to determine the problem-solving strategy for diversity events occurred on the distribution system. The events include events related to the fault, scheduled outage and optimal operating task such as feeder line fault, line scheduled outage, line overload, system load balancing, system loss minimization, main transformer fault, main transformer scheduled outage, main transformer overload, main transformer protection control. The expert system enhances the reliability of software designed by the integrated concept for the diversity events.

  • PDF

The Overvoltage Analysis Results of 765 kV System in 2005 by TNA (TNA를 이용한 2005년 송전계통의 과전압 해석)

  • Woo, Jung-Wook;Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.209-211
    • /
    • 1997
  • This paper describes the TNA(Transient Network Analyzer) modeling/operating methods and the analysis results of expected overvoltages of 765 kV system in 2005 by the TNA. The power system is expressed as the equivalent inductance of power system, power source, transmission line, switch, and etc. in the TNA. We have examined the overvoltages in the ground fault case, the fault clearing case and the closing/re-closing case. The maximum line-to-line overvoltage is 1.87 p.u., which occurs between SS and SA at the fault clearing case.

  • PDF

The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit (공조설비용 고장진단시스템의 실시간 진단실험)

  • 소정훈;유승신;경남호;신기석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF

Development of Feeder Automation Software Considering the Diversity Events of Distribution Systems (배전계통의 다양한 이벤트들을 고려한 선로자동화 소프트웨어 개발)

  • 고윤석
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.463-470
    • /
    • 2003
  • This paper proposes an expert system, which is able to determine the problem-solving strategy for diversity events occurred on the distribution system. The events include events related to the fault, scheduled outage and optimal operating task such as feeder line fault, line scheduled outage, line overload, system load balancing, system loss minimization, main transformer fault, main transformer scheduled outage, main transformer overload, main transformer protection control. The expert system enhances the reliability of software designed by the integrated concept for the diversity events. The expert system is implemented in C language. And the effectiveness and accuracy for the expert system is verified by simulating the event cases for typical distribution model.

A Novel Distance Relaying Algorithm in a Multi-Agent Protection System of transmission line (Multi-Agent 송전계통 보호시스템에서의 새로운 거리계전 알고리즘)

  • Moon, H.K.;Jin, B.G.;Hyun, S.H.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.217-219
    • /
    • 2003
  • This paper presents a distance relaying algorithm for a transmission line protection with MAS. First, the voltage and fault current of the opposite side are represented as a function of those of the measuring end using source voltages of both ends. These voltages are assumed to be obtained from the transformers protecting agents, periodically in normal state. Then, the fault location expression, independent of fault resistance, is derived with voltage and current in only one end of faulted line used. The suggested algorithm is applied to a simple system with two power sources to show its effectiveness.

  • PDF

Recursive Real Time Fault Locator with Wavelet Method (웨이브릿 기법을 이용한 리커시브 실시간 고장점 표정 시스템 연구)

  • Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1522-1530
    • /
    • 2008
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations (분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘)

  • Shin, Dong-Yeol;Kim, Dong-Myung;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

Development of Pipe Fault Inspection System using Computer Vision (컴퓨터 비젼을 이용한 파이프 불량 검사시스템 개발)

  • 박찬호;양순용;안경관;오현옥;이병룡
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.10
    • /
    • pp.822-831
    • /
    • 2003
  • A computer-vision based pipe-inspection algorithm is developed. The algorithm uses the modified Hough transformation and a line-scanning approach to identify the edge line and the radius of the pipe image, from which the eccentricity and dimension of the pipe-end is calculated. Line and circle detection was performed using Laplace operator with input image, which are acquired from the front and side cameras. In order to minimize the memory usage and the processing time, a clustering method with the modified Hough transformation is introduced for line detection. The dimension of inner and outer radius of pipe is calculated by the proposed line-scanning method. The method scans several lines along the X and Y axes, calculating the eccentricity of inner and outer circle, by which pipes with wrong end-shape can be classified and removed.

Evaluation of Operation Practicality on Line with Aluminum Conductor in Underground T&D Systems (지중송전 및 배전계통에서 알루미늄 도체 선로운용의 실용성 평가)

  • Jang, Ju-Yeong;Lee, Jong-Beom;Kim, Yong-Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.492-499
    • /
    • 2011
  • This paper describes that the evaluation on operation practicality of Al conductor cable will be used instead of Cu conductor cable. Analysis is divided into two kinds of cases as transmission and distribution. To evaluate that Al conductor line has the insulation strength indeed safely, various analysis and calculation such as single line-to-ground fault current, lightning surge and allowance current were carried. Model was established based on real combined transmission and distribution is being used in utility with EMTP. The analysis results on Al and Cu conductor line were compared each other. It was proved that Al conductor line can be operated instead of Cu conductor line without special insulation problem in transmission and distribution, in electrical view point such as overvoltage and allowance current.

A Study on the fault Detection using output Sequence in Combinational Logic Networks (출력순자를 이용한 조합회로의 고장검출에 관한 연구)

  • Han, Hee;Park, Kue-Tae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.4
    • /
    • pp.31-37
    • /
    • 1980
  • In this paper, we are concerned with the problems of fault- detection for combinational logic networks. The method which we can obtain the complete test sets using propagation of primitive test sets is presented by considering the relation between test sets of each line. A new method is proposed that can detect the fault through the observation of the output variance by applying only the test sets equivalent to the number of inputs We found that the method is much improved compared to the conventional fault detecting procedure that requires applying the complete test sets to the logic networks.

  • PDF