• Title/Summary/Keyword: Fault insulator

Search Result 36, Processing Time 0.027 seconds

Comparison with Ultra-Violet and Ultra-Sonic Generated by an Insulator at 22.9kV (22.9kV 애자에서 발생한 자외선과 초음파의 비교)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Young-Seog;Jung, Jin-Soo;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.182-183
    • /
    • 2007
  • Recently, diverse techniques for diagnosis on power equipments of the live wire conditions are developed. These techniques are very important that find out the fault signs in power equipments. This paper is Compared with Ultra-Violet and Ultra-Sonic Generated by an Insulator at 22.9kV. The volume of UV images are increased by the square of the applied voltage. The output signals of ultrasonic are detected at about 20kV to 30kV. Hereafter, through the continuous DAQ and analysis, these techniques are the effective method for the improvement of the exciting diagnosis.

  • PDF

Breakdown Characteritics of XLPE/EPDM on the Treatment Condition of the Interfacial layer (XLPE/EPDM의 계면처리조건에 따른 절연파괴 특성)

  • 한성구;조정형;이창종;박양범;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.230-233
    • /
    • 1996
  • In this paper, We intended to evaluate characteristics of XLPE/EPDM interface which exists in the cable joint. Because the fault was mainly occurred in this interface. We investigated breakdown characteristics of XLPE/EPDM double layered insulator as a funtion of temperature, pressure, annealing time, kinds of jointmaterial. It was shown that breakdown strength of XLPE/EPDM insulators is higher that of XLPE/XLPE or EPDM/EPDM

  • PDF

Breakdown Characteristics of Insulators for a Resistor Type HTS Fault Current Limiter (저항형 고온초전도 한류기용 절연체의 절연 특성)

  • 백승명;류엔반둥;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.48-52
    • /
    • 2004
  • Breakdown characteristics of insulator-liquid nitrogen ($LN_2$) composite insulation for resistor type High $T_c$/ superconducting fault current limiter (HTSFCL) under ac and impulse voltage in $LN_2$ has been studied using model electrode systems. Electrodes for model electrode systems were made of SUS 304 contacted fiberglass reinforced plastic (FRP) and Au coated sapphire. The breakdown characteristics of model electrode systems were investigated experimentally for FRP thickness ranging from 1 mm to 5 mm. surface distance ranging from 2.5 mm to 7 mm and electrode gap ranging from 1 to 5 mm. The experimental data suggested that the breakdown voltage of model electrode systems in $LN_2$ is highly dependent on the surface distance, electrode gap as well as on the FRP thickness. Also, we had observed discharge traces and puncture due to high-voltage 60-Hz AC stress.

Switching Surge Overvoltage and Air Clearance Design of 500 kV Transmission System (500 kV 송전계통의 개폐과전압과 공기절연거리 설계)

  • Shim, E.B.;Kwak, J.S.;Woo, J.W.;Han, K.S.;Kwon, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.644-646
    • /
    • 2005
  • The air clearance of the transmission tower is determined by the switching overvoltage of the system, and the insulator length is determined by contamination design. This paper described the switching overvoltage analysis result of 500 kV system and air clearance design. The overvoltage include fault initiation, fault clearing, closing and reclosing overvoltages. We illustrated the contamination design example, air clearance design of a tower considering swing angle of the conductor.

  • PDF

Processing and Characterization of a Direct Bonded SOI using SiO$_2$ Thin Film (SiO$_2$ 박막을 이용한 SOI 직접접합공정 및 특성)

  • 신동운;최두진;김긍호
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.6
    • /
    • pp.535-542
    • /
    • 1998
  • SOI(silicon oninsulator) was fabricated through the direct bonding of a hydrophilized single crystal Si wafer and a thermally oxidized SiO2 thin film to investigate the stacking faults in silicon at the Si/SiO2 in-terface. At first the oxidation kinetics of SiO2 thin film and the stacking fault distribution at the oxidation interface were investigated. The stacking faults could be divided into two groups by their size and the small-er ones were incorporated into the larger ones as the oxidation time and temperature increased. The den-sity of the smaller ones based critically lower eventually. The SOI wafers directly bonded at the room temperature were annealed at 120$0^{\circ}C$ for 1 hour. The stacking faults at the bonding and oxidation interface were examined and there were anomalies in the distributions of the stacking faults of the bonded region to arrange in ordered ring-like fashion.

  • PDF

A Study on Possibility of Detection of Insulators' Faults by Analyses of Radiation Noises from Insulators (애자의 소음 분석을 통한 애자 고장 탐지 가능성 연구)

  • Park, Kyu-Chil;Yoon, Jong-Rak;Lee, Jae-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.822-831
    • /
    • 2009
  • The porcelain insulators are important devices, that are used to isolate electrically and hold mechanically in the high-voltage power transmission systems. The faults of the insulators induce very serious problems to the power transmission line. In this paper, we introduce techniques for fault detections of insulators by acoustic radiation noises from them. We measured radiation noises from normal state insulators and fault state insulators. The used insulators were two different type porcelain insulators, a cut out switch, two different type line posters, and a lightning arrester. Each results was compared each other in time domain, frequency domain and filter banks' outputs. We found the possibility of detection of insulators' faults and also suggested techniques for fault detections.

The $ Si-SiO_2$ interface structure of a SIMOX SOI formed by 100keV $O^+$ ion beam (100 keV $O^+$ 이온 빔에 의한 SIMOX SOI의 $ Si-SiO_2$계면 구조)

  • 김영필;최시경;김현경;문대원
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 1998
  • - The Si-$SiO_2$ interface of silicon on insulator (SOI) formed by 100 keV $O^+$ was ohserved using high resolution transmission electron microscopy (HRTEM), before and after annealing. The interface of as-implanted sample, ~$5\times 10^{17}\textrm{cm}^{-2}O^+$ implanted at $550^{\circ}C$ was very rough and it has many defectsoxide precipitate, stacking fault, coesite $SiO_2$ etc. However, the interface became flat by high temperature annealing at $1300^{\circ}C$ for 4 hour. It's roughness, observed by HRTEM, was comparable to the interface roughness of 3 keV $O_2^\;+$ ion beam oxide and -6 nm gate oxide formed by thermal oxidation.

  • PDF

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

A study on the Unbalanced Insulation of the Double Circuit 154 kV Transmission Lines to Reduce Lightning Failure Rate (뇌사고율 저감을 위한 154 kV 송전선의 차등절연 적용 방안 연구)

  • Kwak, J.S.;Kang, Y.W.;Woo, J.W.;Shim, E.B.;Kim, W.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.151-159
    • /
    • 2003
  • According to the records, approximately 50 percent of power failure were caused by lightning. Conventional fault preventive measures against lightning include reduction of the footing resistance of the tower, multiplication of overhead ground wires and unbalanced insulation of the double circuit transmission tower. In addition to these, transmission line arresters have been recently appeared as an alternatives. In this paper an unbalanced insulation method with transmission line arrester was assumed as another countermeasure against simultaneous double circuit trip of 154 kV transmission line by lightning strike. The lightning performance of line arrester was compared with conventional insulation concept using different numbers of porcelain and glass insulator. Larger numbers of insulator simply increase flashover current level by lightning but the lightning performance doesn't proportional to it. EMTP simulation and predictive calculation of lightning failure rate were carried out to evaluate the performance.

  • PDF

Analysis of Transformer Fluid Aging from Overload Operation (지중 저압접속함의 침수조건에 따른 전위 분석)

  • Joung, Jong-Man;Lee, Byung-Sung;Choi, Jong-Gi;Jeong, Yeon-Ha;Park, Cheol-Bae;Song, Il-Kun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.284-287
    • /
    • 2006
  • In this paper variety test results were discussed regarding to the ground potential increase. The tests conducted with a joint box simulating leakage point having an insulator fault. Inside the joint box three-phase cables and one neutral line were connected and the insulator at jointed part was peeled from the one of three-phase cables. The potentials around manhole cover were measured with the variation of manhole material, ground resistance and water resistance when the manhole was flooded. The potentials induced by an electric leakage were drastically decreased with increasing the distance from the leakage location and with less ground resistance.

  • PDF