• Title/Summary/Keyword: Fault detection and classification

Search Result 128, Processing Time 0.021 seconds

Ensemble Methods Applied to Classification Problem

  • Kim, ByungJoo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.47-53
    • /
    • 2019
  • The idea of ensemble learning is to train multiple models, each with the objective to predict or classify a set of results. Most of the errors from a model's learning are from three main factors: variance, noise, and bias. By using ensemble methods, we're able to increase the stability of the final model and reduce the errors mentioned previously. By combining many models, we're able to reduce the variance, even when they are individually not great. In this paper we propose an ensemble model and applied it to classification problem. In iris, Pima indian diabeit and semiconductor fault detection problem, proposed model classifies well compared to traditional single classifier that is logistic regression, SVM and random forest.

ADAPTIVE FDI FOR AUTOMOTIVE ENGINE AIR PATH AND ROBUSTNESS ASSESSMENT UNDER CLOSED-LOOP CONTROL

  • Sangha, M.S.;Yu, D.L.;Gomm, J.B.
    • International Journal of Automotive Technology
    • /
    • v.8 no.5
    • /
    • pp.637-650
    • /
    • 2007
  • A new on-line fault detection and isolation(FDI) scheme has been proposed for engines using an adaptive neural network classifier; this paper investigates the robustness of this scheme by evaluating in a wide range of operational modes. The neural classifier is made adaptive to cope with the significant parameter uncertainty, disturbances, and environmental changes. The developed scheme is capable of diagnosing faults in the on-line mode and can be directly implemented in an on-board diagnosis system(hardware). The robustness of the FDI for the closed-loop system with crankshaft speed feedback is investigated by testing it for a wide range of operational modes, including robustness against fixed and sinusoidal throttle angle inputs, change in load, change in an engine parameter, and all changes occurring simultaneously. The evaluations are performed using a mean value engine model(MVEM), which is a widely used benchmark model for engine control system and FDI system design. The simulation results confirm the robustness of the proposed method for various uncertainties and disturbances.

Condition Monitoring of an LCD Glass Transfer Robot Based on Wavelet Packet Transform and Artificial Neural Network for Abnormal Sound (LCD 라인의 음향 특성신호에 웨이브렛 변환과 인경신경망회로를 적용한 공정로봇의 건정성 감시 연구)

  • Kim, Eui-Youl;Lee, Sang-Kwon;Jang, Ji-Uk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.813-822
    • /
    • 2012
  • Abnormal operating sounds radiated from a moving transfer robot in LCD (liquid crystal display) product lines have been used for the fault detection line of a robot instead of other source signals such as vibrations, acoustic emissions, and electrical signals. Its advantage as a source signal makes it possible to monitor the status of multiple faults by using only a microphone, despite a relatively low sensitivity. The wavelet packet transform for feature extraction and the artificial neural network for fault classification are employed. It can be observed that the abnormal operating sound is sufficiently useful as a source signal for the fault diagnosis of mechanical components as well as other source signals.

Development of Nuclear Power Plant Instrumentation Signal Faults Identification Algorithm (원전 계측 신호 오류 식별 알고리즘 개발)

  • Kim, SeungGeun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.6
    • /
    • pp.1-13
    • /
    • 2020
  • In this paper, the author proposed a nuclear power plant (NPP) instrumentation signal faults identification algorithm. A variational autoencoder (VAE)-based model is trained by using only normal dataset as same as existing anomaly detection method, and trained model predicts which signal within the entire signal set is anomalous. Classification of anomalous signals is performed based on the reconstruction error for each kind of signal and partial derivatives of reconstruction error with respect to the specific part of an input. Simulation was conducted to acquire the data for the experiments. Through the experiments, it was identified that the proposed signal fault identification method can specify the anomalous signals within acceptable range of error.

Optical In-Situ Plasma Process Monitoring Technique for Detection of Abnormal Plasma Discharge

  • Hong, Sang Jeen;Ahn, Jong Hwan;Park, Won Taek;May, Gary S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.71-77
    • /
    • 2013
  • Advanced semiconductor manufacturing technology requires methods to maximize tool efficiency and improve product quality by reducing process variability. Real-time plasma process monitoring and diagnosis have become crucial for fault detection and classification (FDC) and advanced process control (APC). Additional sensors may increase the accuracy of detection of process anomalies, and optical monitoring methods are non-invasive. In this paper, we propose the use of a chromatic data acquisition system for real-time in-situ plasma process monitoring called the Plasma Eyes Chromatic System (PECS). The proposed system was initially tested in a six-inch research tool, and it was then further evaluated for its potential to detect process anomalies in an eight-inch production tool for etching blanket oxide films. Chromatic representation of the PECS output shows a clear correlation with small changes in process parameters, such as RF power, pressure, and gas flow. We also present how the PECS may be adapted as an in-situ plasma arc detector. The proposed system can provide useful indications of a faulty process in a timely and non-invasive manner for successful run-to-run (R2R) control and FDC.

A study on the outlier data estimation method for anomaly detection of photovoltaic system (태양광 발전 이상감지를 위한 아웃라이어 추정 방법에 대한 연구)

  • Seo, Jong Kwan;Lee, Tae Il;Lee, Whee Sung;Park, Jeom Bae
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.403-408
    • /
    • 2020
  • Photovoltaic (PV) has both intermittent and uncertainty in nature, so it is difficult to accurately predict. Thus anomaly detection technology is important to diagnose real time PV generation. This paper identifies a correlation between various parameters and classifies the PV data applying k-nearest neighbor and dynamic time warpping. Results for the two classifications showed that an outlier detection by a fault of some facilities, and a temporary power loss by partial shading and overall shading occurring during the short period. Based on 100kW plant data, machine learning analysis and test results verified actual outliers and candidates of outlier.

Reinforcement Method for Automated Text Classification using Post-processing and Training with Definition Criteria (학습방법개선과 후처리 분석을 이용한 자동문서분류의 성능향상 방법)

  • Choi, Yun-Jeong;Park, Seung-Soo
    • The KIPS Transactions:PartB
    • /
    • v.12B no.7 s.103
    • /
    • pp.811-822
    • /
    • 2005
  • Automated text categorization is to classify free text documents into predefined categories automatically and whose main goals is to reduce considerable manual process required to the task. The researches to improving the text categorization performance(efficiency) in recent years, focused on enhancing existing classification models and algorithms itself, but, whose range had been limited by feature based statistical methodology. In this paper, we propose RTPost system of different style from i.ny traditional method, which takes fault tolerant system approach and data mining strategy. The 2 important parts of RTPost system are reinforcement training and post-processing part. First, the main point of training method deals with the problem of defining category to be classified before selecting training sample documents. And post-processing method deals with the problem of assigning category, not performance of classification algorithms. In experiments, we applied our system to documents getting low classification accuracy which were laid on a decision boundary nearby. Through the experiments, we shows that our system has high accuracy and stability in actual conditions. It wholly did not depend on some variables which are important influence to classification power such as number of training documents, selection problem and performance of classification algorithms. In addition, we can expect self learning effect which decrease the training cost and increase the training power with employing active learning advantage.

CNN based data anomaly detection using multi-channel imagery for structural health monitoring

  • Shajihan, Shaik Althaf V.;Wang, Shuo;Zhai, Guanghao;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.181-193
    • /
    • 2022
  • Data-driven structural health monitoring (SHM) of civil infrastructure can be used to continuously assess the state of a structure, allowing preemptive safety measures to be carried out. Long-term monitoring of large-scale civil infrastructure often involves data-collection using a network of numerous sensors of various types. Malfunctioning sensors in the network are common, which can disrupt the condition assessment and even lead to false-negative indications of damage. The overwhelming size of the data collected renders manual approaches to ensure data quality intractable. The task of detecting and classifying an anomaly in the raw data is non-trivial. We propose an approach to automate this task, improving upon the previously developed technique of image-based pre-processing on one-dimensional (1D) data by enriching the features of the neural network input data with multiple channels. In particular, feature engineering is employed to convert the measured time histories into a 3-channel image comprised of (i) the time history, (ii) the spectrogram, and (iii) the probability density function representation of the signal. To demonstrate this approach, a CNN model is designed and trained on a dataset consisting of acceleration records of sensors installed on a long-span bridge, with the goal of fault detection and classification. The effect of imbalance in anomaly patterns observed is studied to better account for unseen test cases. The proposed framework achieves high overall accuracy and recall even when tested on an unseen dataset that is much larger than the samples used for training, offering a viable solution for implementation on full-scale structures where limited labeled-training data is available.

Determination of PCB film of Un-peeling Defect Using Deep Learning (딥러닝을 이용한 PCB 필름 미박리 양품 판정)

  • Jeong-Gu, Lee;Young-Chul, Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1075-1080
    • /
    • 2022
  • Recently, the effort is continuously applied in machine learning and deep learning algorithm which is represented as artificial intelligence algorithm in the varies field such as prediction, classification and clustering. In this paper, we propose detection algorithm for un-peeling status of PCB protection film by using Dectron2. We use 42 images of data as training and 19 images of data as testing based on 61 images which was taken under the condition of a critical reflection angel of 42.8°. As a result, we get 16 images that was detected and 3 images that was not detected among 19 images of testing data.

Fault state detection and remaining useful life prediction in AC powered solenoid operated valves based on traditional machine learning and deep neural networks

  • Utah, M.N.;Jung, J.C.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1998-2008
    • /
    • 2020
  • Solenoid operated valves (SOV) play important roles in industrial process to control the flow of fluids. Solenoid valves can be found in so many industries as well as the nuclear plant. The ability to be able to detect the presence of faults and predicting the remaining useful life (RUL) of the SOV is important in maintenance planning and also prevent unexpected interruptions in the flow of process fluids. This paper proposes a fault diagnosis method for the alternating current (AC) powered SOV. Previous research work have been focused on direct current (DC) powered SOV where the current waveform or vibrations are monitored. There are many features hidden in the AC waveform that require further signal analysis. The analysis of the AC powered SOV waveform was done in the time and frequency domain. A total of sixteen features were obtained and these were used to classify the different operating modes of the SOV by applying a machine learning technique for classification. Also, a deep neural network (DNN) was developed for the prediction of RUL based on the failure modes of the SOV. The results of this paper can be used to improve on the condition based monitoring of the SOV.