• Title/Summary/Keyword: Fault Zone

Search Result 405, Processing Time 0.026 seconds

Studies on Mineral Composition of Fault Clay in Quaternary Ipsil Fault: High Resolution Powder Diffraction Analysis (제4기 입실 단층 파쇄대에서 나타나는 단층점토의 산출상태에 따른 광물조성 연구: 고해상도분말회절 분석을 중심으로)

  • Park, Sung-Min;Kang, Han;Jang, Yun-Deuk;Im, Chang-Bock;Kim, Jeong-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.2 s.52
    • /
    • pp.83-89
    • /
    • 2007
  • XRD, HRPD and SEM were used for mineralogical characterization of fault clay in fracture zone from Ipsil. Variations of color in fault clay exhibit significant mineral composition difference. Fault clays from Ipsil are composed mainly of smectite, laumontite, and quartz. Laumontite, a distinct fault clay in Ipsil fault, might be resulted from alteration of bed rock in fracture zone based on the result that no laumontite was found near fault rock. Fault clays from Ipsil are composed mainly of smectite.

Geotechnical treatment for the fault and shattered zones under core foundation of fill dam (단층 및 파쇄대가 분포하는 Fill Dam 기초의 보강대책)

  • 김연중;최명달
    • The Journal of Engineering Geology
    • /
    • v.2 no.1
    • /
    • pp.19-35
    • /
    • 1992
  • aThe elastic properties of the fault zone (width; 3~12m), the shattered zone (width; over 40m) and the fresh rock zone distributed under the core foundation of fill dam in granitic gneiss have widely different range. The deformation moduli of the fresh rock zone, the fault zone and the shattered zone obtained from in situ rock tests - Plate Load Test and Bore Hole Deformation Test - show a range of $42,000~168,000kg/\textrm{cm}^2,{\;}963~2,204kg/\textrm{cm}^2{\;}and{\;}1,238~2,098kg/\textrm{cm}^2$, respectively. The differential settlements hetween the fault zone and the fresh rock zone are expected after the dam construction. Therefore, the displacement of foundation and concrete fill are evaluated using FEADAM 84 program of finite element analysis. The geometric distribution of discontinuifies obtained from the site mapping and drilling is considered in the finite element analysis. The analysis shows that the differential settlements between the fault zone and the fresh rock zone is about 6cm, while that of concrete fill is within 0.5cm.

  • PDF

Identification of the Singal Fault Zone in the Kiheung Reservoir Area by Geotechnical Investigations (기흥저수지 지역의 지반조사를 통한 신갈단층대 확인)

  • Gwon, Sun-Dal;Kim, Sun-Kon;Lee, Soung-Han;Park, Kwon-Gyu
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.295-306
    • /
    • 2012
  • In this study, the Singal fault zone in the Gyeonggi massif is identified in the Kiheung area. Geotechnical investigations were carried out to locate and characterize of the Singal fault zone in the Kiheung reservoir area. The N-S striking Shingal fault is known to be a Riedel-type strike-slip fault within the Choogaryung rift. Along the fault zone, 62 bore holes were drilled and electrical resistivity survey of about 11km, and vibroseis seismic refraction and reflection survey of about 500m were done. From the result of investigations, it is found that the fault zone, consisting mainly of gouge and breccia, has maximum width of 300 meters with anastomosing geometry of secondary fractures developed subparallel to the fault zone. We interpret these geometric features to be the result of structural development of flower-structure type at the restraining band of strike-slip fault. However, there are uncertainties of this interpretation because there are virtually no outcrops in the area. Further investigation to understand geometric features and linkage style of the fault zone.

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

Distribution of Fault-related Landforms and Lineaments Along the Ulsan Fault Zone (울산단층대 주변의 단층 지형 및 선구조 분포)

  • Lee, Gwang-Ryul;Park, Chung-Sun;Shin, Jae-Ryul
    • Journal of The Geomorphological Association of Korea
    • /
    • v.25 no.3
    • /
    • pp.89-103
    • /
    • 2018
  • This study presents results of analysis on fault-related landforms and the Quaternary fluvial landforms, which are important evidences for active faulting by identifying surface deformation, around the Ulsan Fault Zone. In addition, this study suggests lineament map and inferred active fault-line map based on analyzing linearity and continuity of these landforms and by compiling location information of existing active faults. We convince that quantitative tectonic-geomorphological analysis are an effective method for active faults tracking, in particular, considering the conditions of relatively low seismicity and surface ruptured-events in the Korean Peninsula compared to plate boundary active areas. However, research on active fault in South Korea is just an infant stage since the 1990s and requires accumulation of research achievements on development and application of various fault analysis techniques, analysing and standardizing linear structures.

A Report for the Quaternary Gaegok 6 Fault Developed in the Mid-eastern Part of Ulsan Fault Zone, Korea (울산단층대 중동부에 발달하는 제4기 개곡 6단층에 대한 보고)

  • Ryoo, Chung-Ryul
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.635-643
    • /
    • 2009
  • In this paper, a Quaternary fault is described, which is developed in the mid-eastern part of Ulsan Fault Zone, near the southern Gaegok-ri, Oedong-eub, Gyeongju, Korea. The Gaegok 6 fault is developed along the contact between Early Tertiary granite and Quaternary gravel deposit overlying unconformably the granite. The fault strikes $N02^{\circ}{\sim}22^{\circ}E$ and dips $45^{\circ}{\sim}80^{\circ}$ to the west. This fault has a 30~50 cm wide cataclastic shear zone with gouge zone, mixed with Quaternary sediments and fault breccia of granite. In the main Quaternary fault plane, the orientation of striation is $17^{\circ}$, $356^{\circ}$, indicating a dextral strike-slip faulting with some normal component. There is another striation ($78^{\circ}$, $278^{\circ}$ and $43^{\circ}$, $270^{\circ}$) with reverse-slip sense, developed on the subsidiary plane which cuts the main Quaternary fault plane. In brief, the fault has been developed between the granite in the western part and the Quaternary gravel deposit in the eastern part. The western block of fault is uplifted. The striations and movement senses of faults indicate multiple compressional stages in this region. The fault has a similar orientation, westward dipping geometric pattern, and reverse sensed kinematic pattern with Gaegok 1 fault developed in the north. Thus, the Gaegok 6 fault is probably a southern extension of Gaegok 1 fault.

A study on the optimal reinforcement area for excavation of a small cross-section shield TBM tunnel in fault fracture zone through parameter analysis (매개변수 분석을 통한 단층파쇄대의 소단면 쉴드 TBM 터널 굴착 시 최적 보강영역 연구)

  • Kang, Byung-Yun;Park, Hyung Keun;Cha, Jae-Hoon;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.261-275
    • /
    • 2020
  • When excavating a small cross-section tunnel in a fault fracture zone using the shield TBM method, there is a high possibility of excessive convergence and collapse. Appropriate ground reinforcement is required to minimize construction cost loss and trouble due to a fault fracture zone. In this study, the optimal reinforcement area was suggested and the surrounding ground behavior was investigated through numerical analysis using MIDAS GTS NX (Ver. 280). For the parameters, the width of the fault fracture zone, the existence of fault gouge, and the groundwater level and depth of cover were applied. As a result, when there is not fault gouge, the convergence and ground settlement are satisfied the standard when applying ground reinforcement by up to 0.5D. And, due to the high permeability coefficient, it is judged that it is necessary to apply 0.5D reinforcement. There is a fault gouge, it was possible to secure stability when applying ground reinforcement between the entire fault fracture zone from the top of the tunnel to 0.5D. And, because the groundwater discharge occurred within the standard value due to the fault gouge, reinforcement was unnecessary.

Model-based fault detection and isolation of a linear system (선형시스템의 모델기반 고장감지와 분류)

  • 이인수;전기준
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.1
    • /
    • pp.68-79
    • /
    • 1998
  • In this paper, we propose a model-based FDI(fault detetion and isolation) algorithm to detect and isolate fault in a linear system. The proposed algorithm is gased on an HFC(hydrid fault classifier) which consists of an FCART2(fault classifier by ART2 neural network) and an FCFM(fault classifier by fault models) which operate in parallel to isolate faults. The proposed algorithm is functionally composed of three main parts-parameter estimation, fault detection, and isolation. When a change in the system occurs, the estimated parameters go through a transition zone in which errors between the system output and the stimated output and the estimated output cross a predetermined thrseshold, and in this zone the estimated parameters are tranferred to the FCART2 for fault isolation. On the other hand, once a fault in the system is detected, the FCFM statistically isolates the fault by using the error between ach fault model out put and the system output. From the computer simulation resutls, it is verified that the proposed model-based FDI algorithm can be performed successfully to detect and isolate faults in a position control system of a DC motor.

  • PDF

The Study on The Complex Composition By SFCL and Power Equipments for Fault Detection in HVDC Line (HVDC 선로 내 초전도 한류기와 전력기기들의 복합 구성을 통한 고장 검출에 관한 연구)

  • Kim, Myong-Hyon;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1113-1118
    • /
    • 2018
  • Protection in HVDC(High Voltage Direct Current) have the very fast velocity of fault detection. Because Fault in HVDC has the fast propagation, large currents, high interruption cost. The focus to velocity caused possibility of errors like a detection error like a high impedance fault. In this paper, Proposed complex composition for get the reliability and velocity. That used SFCL(Super Conducting Fault Current Limiter), Protection Zone and DTS(Distributed Temperature Sensing). The SFCL was detect the fault by quench and DTS&Protection Zone were perceive the detect by variation too. To examine the proposed method, PSCAD/EMTDC simulated. The results of simulation, proposed methods could the detect of fault to whole HVDC line. And that improved the reliability of fault clearing.

Case Study about the Ground Characteristics Analysis of Tunnel Face Fault Fractured Zone (터널막장 단층파쇄대의 지반특성 분석에 대한 사례연구)

  • Min Kyoung-Nam;Lim Kwang-Su;Jang Chang-Sik;Lim Dae-Hwan
    • Tunnel and Underground Space
    • /
    • v.15 no.2 s.55
    • /
    • pp.111-118
    • /
    • 2005
  • The area of investigation belongs to Okchon metamorphic zone and the fault fractured zone runs parallel to the tunnel direction. It causes the independent decline of tunnel face and the slackness of the tunnel surrounding base so, after all, the severe displacement has occurred within the tunnel. Accordingly, the TSP(Tunnel Seismic Prediction) survey has been performed to investigate the extent of fault fractured zone and to analize its characteristics. Also, we have analized the behavior causes by performing the tunnel face mapping and drilling investigation, and confirmed the position and scale of geological anomaly area and front fractured zone which influences tunnel excavation and supporting. Collected data analyzed ground layer condition through 3 dimensional modeling. Several variables included in the modeling were analyzed by geostastistics. The analysis of the modeling data shows that the belt of weathering by fault fractured zone is developing on the basis of the right side of tunnel and that is decreasing to the left side. The fault fractured zone was confirmed that it has strike, $N0\~5^{\circ}E$ dip NW, and it is consisted of large-scale fractured zone including several anomalies. The severe displacement in tunnel is probably caused by asymmetrical load that n generated by the crossing of discontinuity and the rock strength imbalance of tunnel's both side by fault fractured zone, and judge that need tunnel reinforcement method of grouting etc.