• Title/Summary/Keyword: Fault Monitoring

Search Result 705, Processing Time 0.025 seconds

HM System Design for Fault Tolerance on the IMA System (IMA 시스템에서의 Fault Tolerance를 위한 HM 시스템 설계)

  • Ko, Young-Kwan;Lee, Seung-Hoon;Park, Se-Young;Ban, Chang-Bong;Kang, Dai-Il;Jeong, Jae-Yeop;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.77-86
    • /
    • 2012
  • Avionics system are composed of multiple electronic device that performs important missions the number of electronic devices for the performance of aircraft has been gradually increasing. As a result, cost of development, maintenance and operating have increased. To solve this problem, technology paradigm of avionics has been shifting from federated avionics systems that manage to each system independently to IMA(Integrated Modular Avionics) systems. Unlike federated systems, fault tolerance becomes an essential technology in IMA systems. Because each aircraft features integrated in the an IMA system, a fault can jeopardize the entire system. In this paper, we define faults which can occur on the ARINC 653 based IMA system first, and design the ARINC 653 compliant HM(health Monitoring) system for the system can continue to operate be normal when occur a fault.

A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions (PMSG 적용 가변속 계통연계형 풍력발전 시스템의 통합 시뮬레이션 및 스위치 개방고장 진단기법 연구)

  • Kim, Kyeong-Hwa;Song, Hwa-Chang;Choi, Byoung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.65-78
    • /
    • 2013
  • To analyze influences under open fault conditions in switching devices, an integrated simulation and condition monitoring scheme for a permanent magnet synchronous generator (PMSG) based variable speed grid-connected wind turbine system are presented. Among various faults in power electronics components, the open fault in switching devices may arise when the switches are destructed by an accidental over current, or a fuse for short protection is blown out. Under such a faulty condition, the grid-side inverter as well as the generator-side converter does not operate normally, producing an increase of current harmonics, and a reduction in output and efficiency. As an effective way for a condition monitoring of generation system by online basis without requiring any diagnostic apparatus, the estimation schemes for generated voltage, flux linkage, and stator resistance are proposed and the validity of the proposed scheme is proved through comparative simulations.

Power Plant Fault Monitoring and Diagnosis based on Disturbance Interrelation Analysis Graph (교란들의 인과관계구현 데이터구조에 기초한 발전소의 고장감시 및 고장진단에 관한 연구)

  • Lee, Seung-Cheol;Lee, Sun-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.9
    • /
    • pp.413-422
    • /
    • 2002
  • In a power plant, disturbance detection and diagnosis are massive and complex problems. Once a disturbance occurs, it can be either persistent, self cleared, cleared by the automatic controllers or propagated into another disturbance until it subsides in a new equilibrium or a stable state. In addition to the Physical complexity of the power plant structure itself, these dynamic behaviors of the disturbances further complicate the fault monitoring and diagnosis tasks. A data structure called a disturbance interrelation analysis graph(DIAG) is proposed in this paper, trying to capture, organize and better utilize the vast and interrelated knowledge required for power plant disturbance detection and diagnosis. The DIAG is a multi-layer directed AND/OR graph composed of 4 layers. Each layer includes vertices that represent components, disturbances, conditions and sensors respectively With the implementation of the DIAG, disturbances and their relationships can be conveniently represented and traced with modularized operations. All the cascaded disturbances following an initial triggering disturbance can be diagnosed in the context of that initial disturbance instead of diagnosing each of them as an individual disturbance. DIAG is applied to a typical cooling water system of a thermal power plant and its effectiveness is also demonstrated.

An Effective Push Fault Management Algorithm for Distributed Object Replica based on Standard Middleware (표준 미들웨어 기반 분산 객체 리플리카를 위한 효과적 푸쉬 결함 관리 알고리즘)

  • Kim Boon-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.37-46
    • /
    • 2005
  • In Processing many operations based on distributed environment, it is very important to support the reliability of resources. Providers of resources generally adapt the structure of server-replication to support the reliability of services. Tn server side, it maintains replicas. duplicated server objects. In the structure of this replication, service of stable replica is very important. Therefore the structure to diagnosis the fault of such replica is required. In this Paper, we suggested an effective PUSH fault management algorithm based on PUSH monitoring style of CORBAto overcome weak points of the PULL monitoring style of the replication management system in the distributed object system. Outcomes of the suggested PUSH fault monitoring style were better than other system. We confirmed valuable result in the workloads and timeout-rates.

  • PDF

On the Detection of Induction-Motor Rotor Fault by the Combined “Time Synchronous Averaging-Discrete Wavelet Transform” Approach

  • Ngote, Nabil;Ouassaid, Mohammed;Guedira, Said;Cherkaoui, Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2315-2325
    • /
    • 2015
  • Induction motors are widely used in industrial processes since they offer a very high degree of reliability. But like any other machine, they are vulnerable to faults, which if left unmonitored, might lead to an unexpected interruption at the industrial plant. Therefore, the condition monitoring of the induction motors have been a challenging topic for many electrical machine researchers. Indeed, the effectiveness of the fault diagnosis and prognosis techniques depends very much on the quality of the fault features selection. However, in induction-motor drives, rotor defects are the most complex in terms of detection since they interact with the supply frequency within a restricted band around this frequency, especially in the no-loaded case. To overcome this drawback, this paper deals with an efficient and new method to diagnose the induction-motor rotor fault based on the digital implementation of the monitoring algorithm based on the association of the Time Synchronous Averaging technique and Discrete Wavelet Transform. Experimental results are presented in order to show the effectiveness of the proposed method. The obtained results are largely satisfactory, indicating a promising industrial application of the combined “Time Synchronous Averaging – Discrete Wavelet Transform” approach.

Monitoring of Chemical Processes Using Modified Scale Space Filtering and Functional-Link-Associative Neural Network (개선된 스케일 스페이스 필터링과 함수연결연상 신경망을 이용한 화학공정 감시)

  • Park, Jung-Hwan;Kim, Yoon-Sik;Chang, Tae-Suk;Yoon, En-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.12
    • /
    • pp.1113-1119
    • /
    • 2000
  • To operate a process plant safely and economically, process monitoring is very important. Process monitoring is the task to identify the state of the system from sensor data. Process monitoring includes data acquisition, regulatory control, data reconciliation, fault detection, etc. This research focuses on the data recon-ciliation using scale-space filtering and fault detection using functional-link associative neural networks. Scale-space filtering is a multi-resolution signal analysis method. Scale-space filtering can extract highest frequency factors(noise) effectively. But scale-space filtering has too large calculation costs and end effect problems. This research reduces the calculation cost of scale-space filtering by applying the minimum limit to the gaussian kernel. And the end-effect that occurs at the end of the signal of the scale-space filtering is overcome by using extrapolation related with the clustering change detection method. Nonlinear principal component analysis methods using neural network have been reviewed and the separately expanded functional-link associative neural network is proposed for chemical process monitoring. The separately expanded functional-link associative neural network has better learning capabilities, generalization abilities and short learning time than the exiting-neural networks. Separately expanded functional-link associative neural network can express a statistical model similar to real process by expanding the input data separately. Combining the proposed methods-modified scale-space filtering and fault detection method using the separately expanded functional-link associative neural network-a process monitoring system is proposed in this research. the usefulness of the proposed method is proven by its application a boiler water supply unit.

  • PDF

Study for Optimized Depot System of Train Monitoring System (철도차량 모니터 장치의 지상장치 최적화 기법에 관한 연구)

  • 주해진;한정수;박성호;홍구선
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.497-502
    • /
    • 2002
  • TGIS(Train General Information System) is monitoring Train status and analyzing fault happened. TGIS informed a lot of Passenger data, Driving data, Status data and Fault data to 'Depot'. For dealing them more properly, TGIS need specified data and specialized data handling method. This paper suggest Optimize data of Train Monitoring System and Apply that to Main Line Car.

  • PDF

Fault diagnosis of walking beam roller bearing by FTA (FTA(Fault Tree Analysis)기법을 이용한 이송용 대부하 베어링 고장 진단)

  • Bae, Y.H.;Lee, H.K.;Lee, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.110-123
    • /
    • 1994
  • The development of automatic production systems have required inteligent diagnostic and monitoring function to repair system failure and reduce production loss by the failure. In order to perform accurate functions of intelligent system, inferencing about total system failure and fault analysis due to each mechanical component failures are required. Also the solution about repair and maintenance can be suggested from these analysis results. As an essential component of mechanical system, a bearing system is investigated to define the failure behavior. The bearing failure is caused by lubricant system failure, metallurgical defficiency, mechanical condition(vibration, overloading, misalignment) and environmental effect. This study described roller bearing fault train due to stress variation and metallurgical defficiency from lubricant failure by using FTA.

  • PDF

Remote Fault Diagnosis and Maintenance System for NC Machine Tools (공작기계용 원격 고장진단 및 보수 시스템)

  • 신동수;현웅근;정성종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.19-25
    • /
    • 1998
  • Remote fault diagnosis and maintenance system using general telecommunication network is necessary for an effective fault diagnosis and higher productivity of NC machine tools. In order to monitor machine tool condition and diagnose alarm states due to electrical and mechanical faults, a remote data communication system for monitoring of NC machine fault diagnosis and status is developed. The developed system consists of (1) remote communication module among NC's and host PC using PSTN. (2) 8 channels analog data sensing module, (3) digital I/O module for control or NC machine, (4) communication module between NC machine and remote data communication system via RS-232C, and (5) software man-machine interface. Diagnostic monitoring results generated through a successive type inference engine are displayed in user-friendly graphics. The validity and reliability of the developed system is verified to be a powerful commercial version on a vertical machining center through a series of experiments.

  • PDF