• Title/Summary/Keyword: Fault Management Method

Search Result 216, Processing Time 0.026 seconds

The method of development for enhancing reliability of missile assembly test set (유도탄 점검 장비의 신뢰성 향상을 위한 개발 방법)

  • Koh, Sang-Hoon;Han, Seok-Choo;Lee, Kye-Shin;Lee, You-Sang;Kim, Young-Kuk;Park, Dong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.37-43
    • /
    • 2018
  • A developer solves problems with isolating failures if faults are detected when inspecting missiles using the missile assembly test set (MATS) and then resumes the testing. In order to identify faults, it is necessary to analyze the data coming from the equipment, but the information received may not be sufficient, depending on the inspection environment. In this case, the developer repeats the test until the problem is reproduced or checks the performance of each piece of equipment that is related to the fault. When this task is added, schedule management becomes problematic, and development costs rise. To solve this problem, we need to design a MATS in a systematic way to increase fault coverage while satisfying the required reliability. By designing the necessary processes for each procedure, it is possible to reduce the fault identification time when a fault is detected during operations. But it is not possible to guarantee 100% fault coverage, so we provide another method by comparing costs and effects. This paper describes a development method to enhance the reliability of the missile assembly test set; it describes the expected effects when it is adapted, and describes the limitations of this method.

A Study on Zero Knowledge Proof Blockchain Personal Information Authentication Using Smartphone (스마트폰을 이용한 영지식증명 블록체인 개인정보 인증에 관한 연구)

  • Lee Kwangkyu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.3
    • /
    • pp.37-44
    • /
    • 2023
  • In the future society, a means to verify the identity of the information owner is required at the beginning of most services that the information owner encounters, and the emergence and gradual spread of digital identification that proves the identity of the information owner is essential. In addition, as the utilization value of personal information increases, discussions on how to provide personal information are active. Therefore, there is a need for a personal information management method necessary for building a hyper-connected society that is safe from various hacking, forgery, alteration, and theft by allowing the owner to directly manage and provide personal information management. In this study, a decentralized identity information management model that overcomes the problems and limitations of the centralized identity management method of personal information and manages and selectively provides personal information by the information owner himself and implemented a smart personal information provision system(SPIPS: Smart Personal Information Provision System) using a smartphone.

Web-based Application Service Management System for Fault Monitoring

  • Min, Sang-Cheol;Chung, Tai-Myoung;Park, Hyoung-Woo;Lee, Kyung-Ha;Pang, Kee-Hong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.64-73
    • /
    • 1997
  • Network technology has been developed for very high-speed networking and multimedia data whose characteristics are the continuous and bursty transmission as well as a large amount of data. With this trend users wish to view the information about the application services as well as network devices and system hardware. However, it is rarely available for the users the information of performance or faults of the application services. Most of information is limited to the information related network devices or system hardware. Furthermore, users expect the best services without knowing the service environments in the network and there is no good way of delivering the service related problems and fault information of application services in a high speed network yet. In this paper we present a web-based application management system that we have developed for the past year. It includes a method to build an agent system that uses an existing network management standards, SNMP MIB and SNMP protocols. The user interface of the system is also developed to support visualization effects with web-based Java interface which offers a convenient way not only to access management information but also to control networked applications.

  • PDF

A Fault Monitor Design for the Driving Currents of a DDV Actuation System of a FBW Aircraft (FBW 항공기의 DDV 구동장치에 대한 구동전류 고장 모니터 설계)

  • Nam, Yun-Su;Park, Hae-Gyun;;Choe, Seop;Gwon, Jong-Gwang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.81-86
    • /
    • 2006
  • This paper deals with a driving current fault monitor design methodology for a DDV actuation system which has a dual hydraulic power supply system, and triplex electric control capability. A fault existing among these redundant channels should be detected accurately and removed timely, and the remaining channels are to be reconfigured in order to compensate the role of a removed faulty channel. An integrated analysis on the aerodynamics, flight control laws, and DDV actuation system is essential for the design of an actuation system fault monitor. A method to define a fault transient boundary which specifies a maximum travel of an actuation system caused by the first faulty operation is proposed based on the top level requirement on the fault effect specified in MIL-F-8785C.

Development of fault detection and diagnosis system for the heat source apparatus of building air-conditioning system (공조시스템의 열원기기에 대한 고장검출 및 진단 시스템 개발)

  • Han, Dong-Won;Park, Jong-Soo;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.30-35
    • /
    • 2008
  • This paper describes a fault detection and diagnosis (FDD) system developed for the heat source apparatus in building air-conditioning system. As HVAC&R systems in building become complex and instrumented with highly automated controllers, the processes and systems get more difficult for the operator to understand and detect the mal-functions. Poorly maintained, degraded, and improperly controlled equipment wastes an estimated 15% to 30% of energy used in commercial building. When operating a complex facility, FDD system is beneficial in equipment management to provide the operator with tools which can help in decision making for recovery from a failure of the system. Automated FDD for HVAC&R system has the potential to reduce energy and maintenance costs and improves comfort and reliability. Over the last decade there has been considerable research for developing FDD system for HVAC&R equipment. However, they are being made too much of a theoretical study, so only a small of FDD methods are deployed in the field. This study deduced an actual defect source for the heat source apparatus and suggested a low price FDD method which is ready to be deployed in the field.

  • PDF

The Verification of Case Study and the Construction of Fault Management System of Electrical Facilities through FMEA Method (FMEA기반 전기설비 사고처리시스템 구축 및 사고사례 검증)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.315-317
    • /
    • 2009
  • When happen the electrical facilities accident, the one's diagnosis system of fault cause was constructed by FMEA method. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual stale. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF

Study on the Geological Characteristics and Slope Stability of Nammyeon reservoir in Bonghwa County, Kyungpook Province (경북 봉화군 남면저수지 일대의 지질특성 및 비탈면 안정성 검토)

  • Ihm, Myeong Hyeok;Park, Jin Young
    • Tunnel and Underground Space
    • /
    • v.27 no.2
    • /
    • pp.77-88
    • /
    • 2017
  • The geology of the study area is composed mainly of conglomerate, sandstone, and shale and basalt. It is a rock that has been observed to move relatively recently through various brittle deformation and various stress fields during the recent period. To form a gentle terrain with severe crushing. The slope is located at the intersection of the Taegok Fault in the north-northeast direction and the Bukok Fault in the western north-west direction, and many faults, fault zones and fracture zones of various sizes are developed in the rock bed. In this study, the geological characteristics of the slope are investigated and the countermeasure method is suggested. It is suggested that periodical measurement and analysis should be performed by installing a measuring instrument according to each structure for safety management of the surrounding roads and grounds during construction or reinforcement by the countermeasure method for the slope of the study area.

Evaluation Model of Service Reliability Using a Service Blueprint and FTA (서비스 블루프린트와 FTA를 이용한 서비스 신뢰도 평가모델)

  • Yoo, Jung-Sang;Oh, Hyung-Sool
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.4
    • /
    • pp.194-201
    • /
    • 2012
  • Because the difference between products and services are getting less and less, service and manufacturing companies' efforts are increasingly focused on utilizing services to satisfy customers' needs under today's competitive market environment. The value of services depends on service reliability that is identified by satisfaction derived from the relationship between customer needs and service providers. In this paper, we extend concepts from the fault tree analysis for reliability analysis of tangible systems to services. We use an event-based process model to facilitate service design and represent the relationships between functions and failures in a service. The objective of this research is to propose a method for evaluating service reliability based on service processes using service blueprint and FTA. We can identify the failure mode of service in a service delivery process with a service blueprint. The fuzzy membership function is used to characterize the probability of failure based on linguistic terms. FTA is employed to estimate the reliability of service delivery processes with risk factors that are represented as potential failure causes. To demonstrate implementation of the proposed method, we use a case study involving a typical automotive service operation.

A Study on the Improving Power System Reliability According to the Reactive Power Problem in the Bulk Power Station (대전원단지의 무효전력 출력제약에 따른 영향에 대한 연구)

  • Song, Seok-Ha;Joo, Joan-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.73-75
    • /
    • 2002
  • This paper presents the properly method of system security and facility countermeasures. We performed simulation for yearly peak of Korean power system in 2002 under the reactive power problem in a nuclear power plants. Analysis of the problems in power system operation by power flow, fault and stability study. Establishment of power system optimal operating plan by stabilizer and maintaining the reasonable voltage level.

  • PDF

Prediction of fault zone ahead of tunnel face using x-Rs control chart analysis for crown settlement (천단변위의 x-Rs 관리도 분석을 이용한 터널 막장 전방 단층대 예측)

  • Yun, Hyun-Seok;Seo, Yong-Seok;Kim, Kwang-Yeom
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.361-372
    • /
    • 2014
  • A measurement of tunnel displacement plays an important role for stability analysis and prediction of possible fault zone ahead of tunnel face. In this study, we evaluated characteristics of tunnel behaviour due to the existence and orientation of fault zone based on 3-dimensional finite element numerical analysis. The crown settlement representing tunnel behaviour is acquired at 5 m away from tunnel face in combination with x-Rs control chart analysis based on statistics for trend line and L/C (longitudinal/crown displacement) ratio in order to propose risk management method for fault zone. As a result, x-Rs control chart analysis can enable to predict fault zone in terms of existence and orientation in tunnelling.