• Title/Summary/Keyword: Fault Control

Search Result 1,591, Processing Time 0.041 seconds

A Study on the Seismic Resistance Design of Sway Brace Device using Internet of Things (IoT를 활용한 흔들림 방지 버팀대의 내진설계에 관한 연구)

  • Thak, Sung-In;Yu, Bong-Geun;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.58-62
    • /
    • 2017
  • There is a growing need for seismic resistance design. But it is controversial that standards of sway brace device in non-structural elements for buildings like pump waterway is vary widely. Therefore, in this study to get a valid range of sway brace device in seismic resistance design, using load test of sway brace device. As a result, load of safe range from 0 to 18.5 kN and under 29.4 kN, no structural fault of sway brace device. And using internet of things get a data of seismic resistance design from sensor node like accelerometer, GPS, tilt sensor and temperature sensor through steps of sampling and prediction. These results will be acceptable for monitoring system for seismic resistance in non-structural elements.

Study on a Dynamic master system for Controller Area Network

  • Won, Ji-Woon;Hong, Won-Kee;Lee, Yong-Doo
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.147-151
    • /
    • 2005
  • CAN(Controller Area Network) is a simple and efficient network system for real time control and measurement. As it is not only good at error detection but also strong in electromagnetic interference, CAN has been widely used all over the industries. Basically, CAN needs a master node in charge of sensor data collection, node scheduling for data transmission to a monitoring system and error detection. According to the number of mater nodes, the CAN system is classified into two type of master system. One is a single master system that has only one master node and the other is a multi-master system where any sensor node can become a master node depending on the system's conditions. While it has the advantage of its fault tolerance, the multi-master system will suffer form the overall performance degradation when a defect is found in the master node. It is because all sensor nodes pertaining to a defective master node lose their position. Moreover, it is difficult and expensive to implement. For a single master system, the whole system will be broken down when a problem happens to a single master. In this paper, a dynamic master system is presented that there are several sub-master nodes of which basic functions are those of other sensor nodes at ordinary times but dynamically changed to replace the failing master node. An effective scheduling algorithm is also proposed to choose an appropriate node among sub-master nodes, where each sub-master node has its precedence value. The performance of the dynamic master system is experimented and analyzed.

  • PDF

Redundancy operation method for a distributed public address system (분산형 전관방송 시스템의 이중화 운영 방법)

  • Ryu, Taeha;Kim, Seungcheon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.47-53
    • /
    • 2020
  • In the case of a failure due to equipment deterioration in the public address system or a worker's mistake during construction, broadcasting becomes impossible. In this situation, we have designed a more advanced management broadcast system that can broadcast. The broadcasting service is operated using main broadcasting device, and local broadcasting device operates separately only in the local area. If the main broadcasting device becomes inoperable, the procedure for transferring the control activates the device with the local broadcasting devices based on data backed up by the main controller. This paper proposes an improved method of the conventional emergency broadcasting device duplication method. The existing method could not use the standby equipment in the normal state, but in the proposed method, the standby equipment can be used as local broadcasting equipment in usually. This method enables stable system operation while minimizing resource waste due to redundant configuration of expensive devices.

A Dispatching Method for Manufacturing Process with Quality Volatilities (품질 변동성이 존재하는 제조공정을 위한 작업투입 방안)

  • Shin, Hyun-Joon;Ryu, Jae-Pil;Son, Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1648-1653
    • /
    • 2012
  • In general, fault of a virtually finished product that is value-added one, since it has gone throughout the most of processes, may give rise to quality cost nearly amount to its selling price and can be a main cause that decreases the efficiency of manufacturing process. This paper proposes a dispatching algorithm for manufacturing process with quality volatilities with consideration of due-dates and required quality level. In order to evaluate the proposed algorithm, this paper examines the performance of the proposed method by comparing it with that of the existing dispatching algorithms in terms of minimizing the mean tardiness. In addition, from the perspective of process capability based on required quality level, this study shows the superiority of the proposed dispatching algorithm.

Implementation of Incoming Panel Monitoring System using Open Source Platform and Wi-Fi Networks (오픈소스 플랫폼 및 Wi-Fi를 이용한 수배전반 모니터링 시스템 구현)

  • Kang, Jin-Young;Kang, Hag-Seong;Jeong, Sung-Hak;Park, Mi-Young;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.886-887
    • /
    • 2015
  • There is a growing interest in and demand for power industry acceleration and energy efficiency due to the increased energy consumption, environmental issues. Electronic power IT convergence industries such as intelligent power system has attract attention as new growth engine industry. A large number of sensors and motors are being installed following unmanned, automated in existing incoming panel management system. Observe the operating conditions and rapid response is essential. Despite the need for immediate action to be taken in the event of various later failed to recognize the emergency power can lead to accidents. In this paper, we propose a new architecture of the implementation of incoming panel monitoring system for power monitoring, fault detection, maintenance and system control using open source hardware platform and Wi-Fi networks.

  • PDF

Development of a Smart Grid Monitoring System with Anti-Islanding Function for Electric Vehicle Charging (안티아일랜딩 기능을 적용한 전기자동차 충전계통 연계 스마트그리드 모니터링 시스템 개발)

  • Ro, Sunny;Shin, Bum-Sik;Lee, Kyung-Jung;Ki, Young-Hun;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.31-37
    • /
    • 2012
  • In this paper, we present a smart grid monitoring system connected with electric vehicle charging system using anti-islanding method. Electric vehicles can be charged through remote control of smart grid monitoring system and the charging process may be more stable and more efficient by wireless communication between the Local Area Module and End Modules. It is illustrated by some experiments that electric vehicle charging process may not be interrupted without any serious fault even though the islanding phenomena occurred in the grid if the presented monitoring system was applied to the smart grid system.

A Study about Emission Characteristic of LPG Vehicle on SFTP (LPG 자동차의 SFTP 모드 배출가스 특성에 관한 연구)

  • Kim, Sungwoo;Song, Hoyoung;Lee, Minho;Kim, Kiho
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.74-84
    • /
    • 2016
  • After Sep. 2017, the LEV3 emission standard will be applied to gasoline and gas vehicles in Korea. This standard has HWFET and SFTP standard as well as FTP-75. Most of LPG vehicles were certificated as SULEV in Korea. Until now, only FTP-75 standard is applying for the certification but it is expected that HWFET and SFTP are used after beginning LEV3. In this paper, 8 LPG and 4 gasoline vehicles were tested on FTP-75 and SFTP to check whether the LPG vehicles can meet LEV3 SFTP standard or not and to suggest direction of development. Most of test vehicles did not meet the SFTP standard. To make up for the fault, fuel injection control improvement is needed.

Design of Software Architecture for Integrating of Messages between Semiconductor Equipments (반도체 장비의 메시지 통합을 위한 소프트웨어 구조 설계)

  • Lim, Yong-Muk;Hwang, In-Su;Kim, Woo-Sung;Park, Geun-Duk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.151-159
    • /
    • 2007
  • It is very important to collect all production-related status values during the manufacturing process of semiconductor. The analysis results of the collected data can be used for the operation rate, fault diagnosis, process control and removal of predicted obstacles of equipments, eventually contributing to the improvement of production efficiency. For this propose. many IC makers have adopted EES(Equipment Engineering System). As the use of web has become a daily lift activity lately, it has been suggested to expand the scope of monitoring equipments using HTTP or SOAP protocols. To fulfill the web-based EES, EDA(Equipment Data Aquisition) should be facilitated first by integrating and standardizing various forms of messages generated from many different semiconductor equipments. In this paper, a method for integration between different types of information is suggested based on the analysis of various protocols used for the communication between semiconductor equipments. In addition, a software architecture to support the method is desisted.

  • PDF

An Empirical Study on the Quality Reliability of the Start-up performance of the Fixed Wing Aircraft at low temperature (고정익 항공기 저온 시동 성능의 품질 신뢰성 향상에 관한 실증적 연구)

  • Kim, DW;Jeong, SH
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.1
    • /
    • pp.169-188
    • /
    • 2018
  • Purpose: The purpose of this study is to analyze low-temperature starting performance of the light attacker and to search and improve the aircraft system including battery and Battery Charge and Control Unit(BCCU). Methods: In order to improve the starting up performance of the light attacker at low-temp, various deficiency cause were derived and analyzed using Fault Tree Analysis method. As a result, it was confirmed there were drawbacks in the charging and discharging mechanism of the battery. The inactivation of the battery's electrolyte at low-temp and the premature termination of the battery charge were the main cause. After long error and trial, we improved these problems by improving performance of battery and optimizing the charging algorithm of BCCU. Results: It was confirmed that the problems of starting up failures were solved through the combined performance test of the battery and BCCU, the ground test using the aircraft system and the operation test conducted by Korea Airforce operating unit for 3 months in winter. Conclusion: This study showed that the improvement of quality reliability was achieved and thus the start-up performance issue of the light attacker has been resolved at low temperature. And it is expected that the design methodologies of temperature-affected electrical system of aircraft will contribute to the development of the aircraft industry in the future.

A Preliminary Research on Optical In-Situ Monitoring of RF Plasma Induced Ion Current Using Optical Plasma Monitoring System (OPMS)

  • Kim, Hye-Jeong;Lee, Jun-Yong;Chun, Sang-Hyun;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.523-523
    • /
    • 2012
  • As the wafer geometric requirements continuously complicated and minutes in tens of nanometers, the expectation of real-time add-on sensors for in-situ plasma process monitoring is rapidly increasing. Various industry applications, utilizing plasma impedance monitor (PIM) and optical emission spectroscopy (OES), on etch end point detection, etch chemistry investigation, health monitoring, fault detection and classification, and advanced process control are good examples. However, process monitoring in semiconductor manufacturing industry requires non-invasiveness. The hypothesis behind the optical monitoring of plasma induced ion current is for the monitoring of plasma induced charging damage in non-invasive optical way. In plasma dielectric via etching, the bombardment of reactive ions on exposed conductor patterns may induce electrical current. Induced electrical charge can further flow down to device level, and accumulated charges in the consecutive plasma processes during back-end metallization can create plasma induced charging damage to shift the threshold voltage of device. As a preliminary research for the hypothesis, we performed two phases experiment to measure the plasma induced current in etch environmental condition. We fabricated electrical test circuits to convert induced current to flickering frequency of LED output, and the flickering frequency was measured by high speed optical plasma monitoring system (OPMS) in 10 kHz. Current-frequency calibration was done in offline by applying stepwise current increase while LED flickering was measured. Once the performance of the test circuits was evaluated, a metal pad for collecting ion bombardment during plasma etch condition was placed inside etch chamber, and the LED output frequency was measured in real-time. It was successful to acquire high speed optical emission data acquisition in 10 kHz. Offline measurement with the test circuitry was satisfactory, and we are continuously investigating the potential of real-time in-situ plasma induce current measurement via OPMS.

  • PDF