• Title/Summary/Keyword: Fault Control

Search Result 1,591, Processing Time 0.031 seconds

Functional Testing of Level Crossing Obstruction Detecting System Using Laser Radar Sensor (레이저 레이더 센서를 이용한 건널목 지장물 검지장치의 기능시험)

  • Shin, Dong-Ho;Baek, Jong-Hyen;Choi, Hyeon-Yeong;Kim, Yong-Gyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.307-315
    • /
    • 2014
  • Existing level crossing obstruction detecting system occurs section of not detecting an obstruction by line detecting. Due to installation of decentralized equipment, it has become a problem in terms of safety and maintenance costs. accordingly, We have developed level crossing obstruction detecting system using laser radar sensor in order to solve these problems. In this paper, Describe results of functional test for the developed level crossing obstruction detecting system. functional tests are normal operation test(control unit and sensor unit) and test to display the fault information in event of a failure(control unit and sensor unit). It was confirmed that it works properly all according to functional test of level crossing obstruction detecting system using laser radar sensor.

A Model for Detection and Refinement of Fixed Bending Regions for Improving the Degree of Thickness Uniformity in Rolled Film Manufacturing (롤 형상 필름 생산에서 두께평활도 개선을 위한 고정굴곡부 발현 모형 및 개선 모델)

  • Bae, Jae-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.21-28
    • /
    • 2015
  • As film products are increasingly used in a wide range of areas, from producing traditional flexible packaging to high-tech electronic products, a higher level of quality is demanded. Most film products are made in the form of rolled finished goods, therefore, various quality issues related to their shape characteristics must be addressed. The thickness of the film products is one of the most common and important critical-to-quality attributes (CTQs). Particularly, the degree of thickness uniformity is more important than other thickness parameters, because it will be potential causes of many secondary thickness-related quality problems, such as wrinkles or faulty windings. To control the degree of thickness uniformity, the fixed bending region is oneof the most important CTQs to manage. Fixed bending regions are special points in the transverse direction of a rolled product with consistent minute variations of the thickness gap. This paper describes the measurement and analysis of thickness uniformity data, which were performed in a real manufacturing field of biaxial oriented polypropylene (BOPP) film. In previous researches, quality function deployment (QFD) or fault tree analysis were used to find the most critical process attributes out to controlthe CTQ of thickness uniformity. Whereas, this paper uses traditional control charts to find the most critical process attributes out in this problem. In addition, the selection of one of the major critical process attributes (CTPs) that is expected to affect the CTQ of thickness uniformity is also described. The selected critical-to-process attributes are the controlled temperatures along the transverse direction. A dramatic improvement in thickness uniformity was observed when the selected CTPs were controlled.

Automobile Engine Information Display Device Using CAN Communication (캔 통신을 이용한 자동차 엔진 정보 표시장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.203-210
    • /
    • 2019
  • Most cars today use electronic control to control the state of the engine to achieve optimum performance. This study developed a device for maintaining fault diagnosis and optimal vehicle status by displaying the engine information of a car on the screen in real time using can communication. This system displays information generated from the engine to the driver in real time such as engine intake and exhaust temperature, current battery voltage, tire pressure, RPM, DPF collection amount, torque, and horsepower through the OBD2 socket. You can check immediately. It can help you to drive safely by measuring tire pressure and displaying it on the screen, and it provides a mode to set the shift timing to suit your taste. In particular, in the case of diesel engine cars, the problems caused by smoke can adversely affect the performance and environmental pollution. Therefore, the system was developed to display the DPF collection amount on the system screen to prevent environmental pollution and to manage the vehicle efficiently.

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

DEVELOPMENT OF HARDWARE-IN-THE-LOOP SIMULATION SYSTEM AS A TESTBENCH FOR ESP UNIT

  • Lee, S.J.;Park, K.;Hwang, T.H.;Hwang, J.H.;Jung, Y.C.;Kim, Y.J.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.203-209
    • /
    • 2007
  • As the vehicle electronic control technology quickly grows and becomes more sophisticated, a more efficient means than the traditional in-vehicle driving test is required for the design, testing, and tuning of electronic control units (ECU). For this purpose, the hardware-in-the-loop simulation (HILS) scheme is very promising, since significant portions of actual driving test procedures can be replaced by HIL simulation. The HILS incorporates hardware components in the numerical simulation environment, and this yields results with better credibility than pure numerical simulations can offer. In this study, a HILS system has been developed for ESP (Electronic Stability Program) ECUs. The system consists of the hardware component, which that includes the hydraulic brake mechanism and an ESP ECU, the software component, which virtually implements vehicle dynamics with visualization, and the interface component, which links these two parts together. The validity of HIL simulation is largely contingent upon the accuracy of the vehicle model. To account for this, the HILS system in this research used the commercial software CarSim to generate a detailed full vehicle model, and its parameters were set by using design data, SPMD (Suspension Parameter Measurement Device) data, and data from actual vehicle tests. Using the developed HILS system, performance of a commercial ESP ECU was evaluated for a virtual vehicle under various driving conditions. This HILS system, with its reliability, will be used in various applications that include durability testing, benchmarking and comparison of commercial ECUs, and detection of fault and malfunction of ESP ECUs.

A Proposal for Protocol Conformance Testing Method using Idle Virtual Channel (유휴 가상 채널을 이용한 ATM프로토콜 적합성 시험 방법 제안)

  • Hong, Beom-Kee;Jung, Yoon-Hee;Oh, Chang-Seok;Lee, Joon-Won
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2832-2839
    • /
    • 1997
  • In this paper, a testing architecture and procedure that an idle ATM virtual channel can be utilized for TCP channel is proposed. Four kinds or methodologies for protocol conformance testing have been standardized in ISO. Remote testing method used popularly have some disadvantages that developer must operate system manually in case of System Under Test (SUT) active testing and we cannot control and observe Implementation Under Test (IUT) often. It is proper to adopt distribute testing method than remote test in order to maximize test coverage and optimize fault coverage for conformance testing in ATM systems, and it is required that TCP channel is prepared for distribute testing method. The proposed architecture can adopt distributed testing method without extra physical channel for testing control. Also we can maximize the test coverage and implement the automation of testing without intervention of operator sustaining normal operation of ATM equipment.

  • PDF

An Establishment of Super Wi-Fi Environment in Ships Based on UHF System of TMS

  • Kim, Jungwoo;Son, Jooyoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.5
    • /
    • pp.2103-2123
    • /
    • 2018
  • Ships built today are larger in scale and feature more complex structures. The ever-evolving systems used on board a ship require vast amounts of data processing. In the future, with the advent of smart ships, unmanned ships and other next-generation ships, the volumes of data to be processed will continue to increase. Yet, to date, ship data has been processed using wired networks. Placed at fixed locations, the nodes on wired networks often fail to process data from mobile devices. Despite many attempts made to use Wi-Fi on ships just as on land to create wireless networks, Wi-Fi has hardly been available due to the complex metal structures of ships. Therefore, Wi-Fi on ships has been patchy as the ship-wide total Wi-Fi coverage has not properly implemented. A new ship-wide wireless network environment is part of the technology conducive to the shipbuilding industry. The wireless network environment should not only serve the purpose of communication but also be able to manage and control multiple features in real-time: fault diagnostics, tracking, accident prevention and safety management. To better understand the characteristics of wireless frequencies for ships, this paper tests the widely used TETRA, UHF and Wi-Fi and sheds light on the features, advantages and disadvantages of each technology in ship settings. The proposed deployment of a Super Wi-Fi network leveraging the legacy UHF system of TMS generates a ship-wide wireless network environment. The experimental findings corroborate the feasibility of the proposed ship-wide Super Wi-Fi network environment.

Development of Thermal Power Boiler System Simulator Using Neural Network Algorithm (신경망 알고리즘을 이용한 화력발전 보일러 시스템 시뮬레이터 개발)

  • Lee, Jung Hoon
    • Journal of the Korea Society for Simulation
    • /
    • v.29 no.3
    • /
    • pp.9-18
    • /
    • 2020
  • The development of a large-scale thermal power plant control simulator consists of water/steam systems, air/combustion systems, pulverizer systems and turbine/generator systems. Modeling is possible for all systems except mechanical turbines/generators. Currently, there have been attempts to develop neural network simulators for some systems of a boiler, but the development of simulator for the whole system has never been completed. In particular, autoTuning, one of the key technology developments of all power generation companies, is a technology that can be achieved only when modeling for all systems with high accuracy is completed. The simulation results show accuracy of 95 to 99% or more of the actual boiler system, so if the field PID controller is fitted to this simulator, it will be available for fault diagnosis or auto-tuning.

Analysis of the problems in(SMRT) L-CTC and derivation of measures (서울도시철도(SMRT) L-CTC의 문제점 분석 및 해결 방안 도출)

  • Park, Geum-Heui;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1204-1212
    • /
    • 2008
  • This study enables to troubleshoot the problems of the existing dual system with the help of the implementation of totally dualized fault-tolerant system to L-CTC computer and HADAX, and equipments are simplified and systems are modernized with the addition of the control function, as a upgraded LCP control system, to L-CTC computer on the basis of WINDOWS based O/S switched from DOS environment. An error on Microlok, which is aninterlocking apparatus, forwarded to L-CTC computer ensures to handle the false data during the operation of the system. This paper discusses a sure way to prevent the deterioration of (SMRT) L-CYC system and to bolster its stability with formation of the dual system. Additionally, WINDOW based O/S consisting of L-CTC computer leads to simplification and modernization of facilities and enhances maintenance functions offering centralization for branch offices and machine rooms as well.

  • PDF

Space-Efficient Compressed-Column Management for IoT Collection Servers (IoT 수집 서버를 위한 공간효율적 압축-칼럼 관리)

  • Byun, Siwoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.1
    • /
    • pp.179-187
    • /
    • 2019
  • With the recent development of small computing devices, IoT sensor network can be widely deployed and is now readily available with sensing, calculation and communi-cation functions at low cost. Sensor data management is a major component of the Internet of Things environment. The huge volume of data produced and transmitted from sensing devices can provide a lot of useful information but is often considered the next big data for businesses. New column-wise compression technology is mounted to the large data server because of its superior space efficiency. Since sensor nodes have narrow bandwidth and fault-prone wireless channels, sensor-based storage systems are subject to incomplete data services. In this study, we will bring forth a short overview through providing an analysis on IoT sensor networks, and will propose a new storage management scheme for IoT data. Our management scheme is based on RAID storage model using column-wise segmentation and compression to improve space efficiency without sacrificing I/O performance. We conclude that proposed storage control scheme outperforms the previous RAID control by computer performance simulation.