• 제목/요약/키워드: Fatigue measurement

검색결과 460건 처리시간 0.025초

랜덤하중하의 피로균열진전 데이터를 이용한 ${\Delta}K_{eff}$ 평가법의 정량적 평가 (A Quantitative Evaluation of ${\Delta}K_{eff}$ Estimation Methods Based on Random Loading Crack Growth Data.)

  • 구자석;송지호;강재윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.208-213
    • /
    • 2004
  • Methods for estimation of the effective stress intensity factor range (${\Delta}K_{eff}$) are evaluated for narrow and wide band random loading crack growth test data of 2024-T351 aluminum alloy. Three methods of determining $K_{op}$, visual measurement, ASTM offset compliance method, and the neural network method proposed by Kang and Song, and three methods of estimating ${\Delta}K_{eff}$, conventional, the 2/PI0 and 2/PI methods proposed by Donald and Paris, are compared in a quantitative manner by using the results of fatigue crack growth life prediction under random loading. For all $K_{op}$ determination methods discussed, the 2/PI0 and 2/PI methods of estimating ${\Delta}K_{eff}$ provide better results than conventional method for narrow and wide band random loading data.

  • PDF

전자스페클 간섭시스템을 이용한 피로하중을 받는 균열선단에서 탄소성 영역 측정에 관한 연구 (A Study on the Measurement of Elastic-Plastic Zone at the Crack Tip under Cyclic Loading using ESPI System.)

  • 김경수;신병천;심천식;박진영
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.140-144
    • /
    • 2002
  • In this paper, the plastic zone size ahead of the crack tip of DENT specimen and the crack growth length under cyclic loading were measured by ESPI system. These results of the plastic zone size measured by ESPI system were compared with the plastic zone size proposed by Irwin. The results of tile crack growth length measured by it were also compared with them measured by the image analysis system. It is confirmed that it is possible to measure the plastic zone and crack growth length.

  • PDF

SKD11의 하드터닝 가공 열처리 시편의 표면잔류응력 측정에 관한 연구 (Residual Stress Measurement in Hard Turned Workpiece)

  • 김종혁;이태홍;장동영;한동철
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.148-155
    • /
    • 2003
  • Most manufacturing processes such as welding, cutting and molding generate residual stresses on the surface of manufactured parts. Between compressive and tensile residual stresses, the tensile residual stress is harmful to the surface integrity, which results in reduced fatigue life and causes other structural failures when the service stresses are superimposed on the residual stresses. In the research, the residual stresses in the hardened tool steel (SKD11) were measured using hole-drilling method. The specimens were prepared through hard turning. Most of residual stresses in the machined surface were compressive.

농용(農用) 트랙터의 승차진동(乘車振動) 평가에 관한 연구(III) -승차진동의 측정과 평가- (Evaluation of Ride Vibration of Agricultural Tractors(III) -Measurement and Evaluation of Ride Vibrations-)

  • 정수식;김경욱;문계송
    • Journal of Biosystems Engineering
    • /
    • 제18권3호
    • /
    • pp.191-198
    • /
    • 1993
  • Vertical and horizontal ride vibrations of the selected agricultural tractors were measured and evaluated with respect to the ISO 2631 'guide for the evaluation of human exposure to whole body vibration'. Evaluation showed that at the normal transportation speeds of 1.4~20km/h on both the concret and ground surfaces tractor drivers were exposed to the vibrations whose magnitudes exceed the 8 hour fatigue decreased proficiency boundary in the frequency ranges of 2~16Hz in vertical and 1~2Hz in horizontal directions. Considering that tractor operation becomes as one of the specialized job for the future farming in Korea, measures must be made to protect the drivers against harmful ride vibrations of agricultural tractors.

  • PDF

Damascene 공정으로 제조한 $Bi_{3.25}La_{0.75}Ti_3O_{12}$ 박막 캐패시터 소자 특성 (Properties of $Bi_{3.25}La_{0.75}Ti_3O_{12}$ Thin Film Capacitors Fabricated by Damascene Process)

  • 신상헌;김남훈;이우선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.368-369
    • /
    • 2006
  • Ferroelectric thin films have attracted much attention for applications in nonvolatile ferroelectric random access memories(NVFeRAM) from the view points of high speed operation, low power consumption, and large scale Integration[1,2]. Among the FRAM, BLT is of particular interest. as it is not only crystallized at relatively low processing temperature, but also shows highly fatigue resistance and large remanent polarization Meanwhile, these submicron ferroelectric capacitors were fabricated by a damascene process using Chemical mechanical polishing (CMP). BLT capacitors were practicable by a damascene process using CMP. The P-E hysteresis were measured under an applied bias of ${\pm}5V$ by using an RT66A measurement system. The electric properties such as I-V were determined by using HP4155A analysers.

  • PDF

기존선 터널 주행시의 고속열차 차체가 받는 압력변동 계측 및 분석 (Measurement and analysis of Pressure fluctuation by high speed train passing through tunnels in conventional line)

  • 이억재;박춘수;서승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.883-888
    • /
    • 2004
  • Pressure waves are generated when high speed train runs through the tunnels. These pressure waves not only affect passenger's health, but also can cause fatigue failures on the vehicle structure. The current high speed train should run on the conventional lines. In this study, pressure fluctuations by the high speed trains such as G7 Korea High Speed Train and Korea Train eXpress are measured in the cabin and the carbody surface when they pass through the tunnels. The measured results are analyzed and the related parameters are investigated.

  • PDF

전자스패클패턴 간섭시스템을 이용한 피로하중을 받는 균열선단에서 탄소성 영역 측정에 관한 연구 (A Study on the Measurement of Elastic-Plastic Zone at the Crack Tip under Cyclic Loading using ESPI System)

  • 김경수;심천식
    • 한국해양공학회지
    • /
    • 제16권4호
    • /
    • pp.13-18
    • /
    • 2002
  • The magnitude of the plastic zone around the crack tip of DENT(Double Edge Notched Tension) specimen and the crack growth length under cyclic loading were measured by ESPI(Electronic Speckle Pattern Interferometry) system. The measured magnitude of plastic zone was compared with the equations proposed by Irwin and calculated by a nonlinear static method of MSC/NASTRAN. The measured crack growth length by ESPI system was also compared with the obtained data by the image analysis system. From the study, it is confirmed that the plastic zone and crack growth length can be measured accurately with the high-tech equipment.

광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지 (Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors)

  • 양유창;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

섬유-금속 적층판의 인장 및 압입 하중에서의 손상감지 (Damage Detection of Fiber-Metal Laminates Under Axial and Indentation Load)

  • 양유창;한경섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.370-375
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile and indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

유압전동장치의 유량 압력맥동 특성 (Flow and Pressure Ripple Characteristics of Hydrostatic Transmissions)

  • 김도태;윤인균
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.120-126
    • /
    • 2001
  • This study deals with a flow and pressure ripple characteristics for a hydrostatic transmission(HST) consisting of a vari-able axial piston pump connected in an open loop to a fixed displacement axial piston motor. These flow ripples produced by pump and motor in HST interacts with the source impedances of the pump or motor and dynamic characteristics of the connected pipeline, and results in a pressure ripples, Pressure ripples. Pressure ripples in HSP is major source of vibration, which can lead to fatigue failure of components and cause noise. In this paper, the flow ripples generated by a swash plate type axial piston pump or motor in HST are measured by making use of hydraulic pipeline dynamics and the measured pressure data at two points along the pipeline. By using the self-checking functions, the validity of the method us investigated by comparison with the measured and estimated pressure ripples at the halfway section of the pipeline, and good agreement is achieved.