• 제목/요약/키워드: Fatigue measurement

검색결과 460건 처리시간 0.029초

EFFECTS OF SURFACE ROUGHNESS AND MULTILAYER COATING ON THE CORROSION RESISTANCE OF Ti-6Al-4V ALLOY

  • Ko, Yeong-Mu;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 추계학술발표회초록집
    • /
    • pp.134-135
    • /
    • 2003
  • The dental implant materials required good mechanical properties, such as fatigue strength, combined with a high resistance to corrosion. For increasing fatigue resistance and delaying onset of stress corrosion cracking, shot peening has been used for > 50 years to extend service life of metal components. However, there is no information on the electrochemical behavior of shot peened and hydroxyapatite(HA) coated Ti-6Al-4V alloys. To increase fatigue strength, good corrosion resistance, and biocompatibility, the electrochemical characteristics of Ti/TiN/HA coated and shot peened Ti-6Al-4V alloys by electron beam physical vapor deposition(EB-PVD) have been researched by various electrochemical method in 0.9%NaCl. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. The produced materials were quenched at 1000$^{\circ}C$ under high purity dried Ar atmosphere and were hold at 500$^{\circ}C$ for 2 hrs to achieve the fatigue strength(1140㎫) of materials. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. Shot peening(SP) and sand blasting treatment was carried out for 1, 5, and 10min. On the surface of Ti-6Al-4V alloys using the steel balls of 0.5mm and alumina sand of 40$\mu\textrm{m}$ size. Ti/TiN/HA multilayer coatings were carried out by using electron-beam deposition method(EB-PVD) as shown Fig. 1. Bulk Ti, powder TiN and hydroxyapatite were used as the source of the deposition materials. Electrons were accelerated by high voltage of 4.2kV with 80 - 120mA on the deposition materials at 350$^{\circ}C$ in 2.0 X 10-6 torr vacuum. Ti/TiN/HA multilayer coated surfaces and layers were investigated by SEM and XRD. A saturated calomel electrode as a reference electrode, and high density carbon electrode as a counter electrode, were set according to ASTM GS-87. The potentials were controlled at a scan rate of 100 mV/min. by a potentiostat (EG&G Co.273A) connected to a computer system. Electrochemical tests were used to investigate the electrochemical characteristics of Ti/TiN/HA coated and shot peened materials in 0.9% NaCl solution at 36.5$^{\circ}C$. After each electrochemical measurement, the corrosion surface of each sample was investigated by SEM.

  • PDF

젊은 성인의 근 피로가 발생된 무릎관절 폄근에 냉 찜질과 온 찜질의 적용이 균형, 고유수용성감각 및 근력에 미치는 영향 (Effect of Ice and Hot packs on Balance, Proprioception and Muscle Strength in Young Adults with Knee Extensor Muscle Fatigue )

  • 하헌호;장희진;이동엽;홍지헌;유재호;김진섭;남연교;김성길
    • 대한물리의학회지
    • /
    • 제18권4호
    • /
    • pp.121-131
    • /
    • 2023
  • PURPOSE: The purpose of this study was to evaluate the effects of ice and hot packs on proprioception, balance, and muscle strength in knee extensor muscle fatigue. METHODS: A total of 31 male and female students in their twenties from a university in A, Chungnam, Korea, were selected as participants. Three experiments were conducted to assess static balance, dynamic balance, proprioception, and muscle strength before and after induction of muscle fatigue, and following intervention. RESULTS: In the case of stability typical (ST), a significant difference was observed in pillow with eye open (PO) when a Hot pack was applied (p < .05). The weight distribution index (WDI), showed significant differences in normal eye open (NO) and Normal eye closed (NC) tests when ice packs and hot packs were applied (p < .05). In the dynamic balance assessment using Y-balance, significant differences were observed in all values except for pre- and post-intervention in the medial and lateral directions (p < .05). The recovery of proprioceptive sensation showed a significant difference when ice packs were applied (p < .05). In muscle strength, significant differences were observed in all comparisons between measurement time points (p < .05). CONCLUSION: Rest was most effective for static balance, and cold and warm compresses were most effective in recovering dynamic balance. For proprioception, cold compresses were most effective. Muscle strength had a positive effect on recovery in all three intervention methods. These results show that cold and warm compresses can be useful in the recovery of various functions related to muscle fatigue.

비만 범용 처방(處方)에 대한 탕전후(湯煎後) 경락 기능 진단기(QRIS)의 비만 연관 Code측정 및 수침후(水浸後) Free Radical 측정기를 이용한 측정에 대한 고찰 (An analysis of the measurements of the obesity using the code of Quantum Resonance Imprinting System(QRIS) with infusion and using the Free Radical Measurement(Ultra-weak Chemiluminescence) with soak in water regarding medicines which would be mostly used for the treatment of the obesity)

  • 김재중;임형호;선유진;이동훈
    • 대한추나의학회지
    • /
    • 제1권1호
    • /
    • pp.83-90
    • /
    • 2000
  • Oryeong-San, Pangpungtongseong-San, Rangkyeoksanwha-Tang, Sipeemikwanjoong -Tang and Taeumjoui-Tang are not only examined using the code which are related to overweight in the QRIS but are also investigated the level of Free Radical using the Free Radical Measurement after steeping those 5 prescriptions in water. The results are as follows: 1. We indicated in the study of QRIS that 5 kinds of medicines which used most frequently In the treatment of the obesity appeared to affect the Immune system, spleen, kidneys, pancreas, the fatigue toxicity, TSH, and the metabolic disability but did not influence high on the contents of overweight and those of fatty cell, as well. in addition, there were no significant differences between the prescriptions as regards testosterone and progesterone. 2. In the Free Radical Measurement, Rangkyeoksanwha-Tang evaluated significantly high level of Free Radical, whereas others appear to have the similar level of Free Radical. These findings suggest that the treatment of the obesity affects particular body parts with respect to the control of overweight, although those medicines are not related directly to the areas(such as fatty cell Code), it is possible that they influence on the cure for the obesity. Furthermore, they indicate that with soaking prescription, Free Radical is not produced as much as we expected.

  • PDF

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • 한국해양공학회지
    • /
    • 제35권4호
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.

Development of dynamics simulation model for 3-point hitch of agricultural tractor during plow tillage

  • Mo A Son;Seung Yun Baek;Seung Min Baek;Hyeon Ho Jeon;Ryu Gap Lim;Yong Joo Kim
    • 농업과학연구
    • /
    • 제49권4호
    • /
    • pp.937-948
    • /
    • 2022
  • Agricultural operations are performed in uneven environments by attaching an implement on the 3-point hitch of a tractor. A high load is thus placed on the 3-point hitch, and fatigue and failure of the hitch may occur during agricultural operations. In this study, a dynamic simulation model was developed to predict the load occurring on the eyebolt of a 3-point hitch, which is the main damaged component. The simulation model was developed and validated using agricultural data as simulation input and validation data. The dynamics model was developed using the specifications of a 78 kW class tractor. A measurement system was constructed to measure the simulation input and validation data. The simulation model was validated using a traction load on an eye bolt, which was measured during plow tillage operation. The measurement results showed that the average traction load on the left and right lower link and the top link were 8,099.97, 4,943.06, and 636.11 N, respectively. The simulation results and the measured traction load on the left eyebolt were respectively 610.30 and 597.15 N. The simulation results and measured traction load on the left eyebolt were respectively 1,179.78, and 1,145.06 N. The error between the simulation and measurement data was roughly 2% on the left eyebolt and 3% on the right eyebolt.

Residual Stress Measurement in the Hard Turned SKD Tool Steel

  • Kim, Jong-Hyuk;Lee, Tae-Hong;Jang, Dong-Young;Han, Dong-Chul
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.331-332
    • /
    • 2002
  • Most manufacturing processes such as welding, cutting and molding generate residual stresses on the surface of manufactured parts. Tensile residual stress is harmful to the surface integrity, which results in reduced fatigue life and causes other structural failures when the service stresses are superimposed on the residual stresses. In the research, the residual stresses of the high hardness steel (over $H_{RC}60$) workpiece (SKD11) machined by the hard turning were measured using Hole-drilling Method. Residual stress in the surface of hard turned workpiece was mainly appeared to be compressive stress.

  • PDF

여성 Kleine-Levin syndrome 의증 환자 1례 (One Case of Female Patient with Suspected Kleine-Levin Syndrome)

  • 김상호
    • 대한한의학회지
    • /
    • 제34권1호
    • /
    • pp.179-191
    • /
    • 2013
  • Kleine-Levin syndrome is a rare disorder characterized by recurrent episodes of hypersomnia, hyperphagia, hypersexuality and delusion and hallucination with spontaneous recovery. A 17-year-old female suddenly showed hypersomnia, severe fatigue, and compulsive hyperphagia. She was diagnosed with suspected Kleine-Levin Syndrome. The precipitating factor was an upper respiratory tract infection that the patient had undergone 2 weeks prior. Past psychiatric history included somnambulism and ADHD; her symptoms of ADHD included attention deficit, impulsiveness, hyperactivity, and irritability. This was her third episode. Her hypersomnia was longer in duration but lower in frequency compared with usual KLS. Her low LF/HF ratio in heart rate variability measurement showed high parasympathetic nerve activity. A MMPI report showed some psychological problem. The patient was diagnosed of gastric fever by pattern identification. Her hypersomnia episode improved 6 weeks after onset. This is the first reported case of suspected Kleine-Levin Syndrome in the field of Oriental Medicine in Korea.

VDT 작업을 위한 최적치수 및 작업자세에 관한 연구 (Preferred settings of the VDT workstation dimensions posture)

  • 박수찬;이남식;장명현;김철중
    • 대한인간공학회지
    • /
    • 제10권2호
    • /
    • pp.3-13
    • /
    • 1991
  • As the VDT work constrains work postures because of its work characteristics. VDT worksta- tions should be properly designed so as to be fitted to various types of physical conditions of op- erators. Therefore, in this study, the preferred settings of VDT wrokstation dimensions of operators. Therefore, in this study, the preferred settings of VDT workstation dimensions and work postures were studied in order to determine the appropriate dimensions and the work postures for VDT operators which will alleviate the musculoskeletal troubles or visual fatigue. The scpoe of the study is as follows. 1. Measurement and analysis of the preferred settings of the height of workstation, keyboard, seat, and screen among the experienced VDT operators. 2. Anaysis of the relationship between the preferred settings of workstation height and the seat height control among the experienced VDT operators. 3. Analysis of the work postures of the experienced VDT operators.

  • PDF

Development of Durability Test System for Automobile

  • Jung, Won-Wook;Park, Soon-Chul;Yoon, Young-Jin;Park, Sung-Han;Lee, Young-Jin;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.286-291
    • /
    • 2003
  • In this paper, new measurement and analysis system for the durability test is introduced. Not like previous development cases, newly developed system can process both primary and secondary signals effectively to enhance the analysis performance. Developed system can be easily adopted to the industrial fields with little modifications. Compared to the commercial products, the system showed satisfactory performances.

  • PDF

FBG센서를 이용한 반복하중을 받는 RC보의 계측 시스템 개발 (Development of Measuring Data System of Reinforced Concrete Beam Under Cyclic Loading Using Fiber Bragg Grating Sensors)

  • 곽계환;장화섭;정현수;양동운
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.440-447
    • /
    • 2005
  • In this study, strain measurement and its applicability to estimated deflection curve using fiber bragg grating sensors was conducted. For this purpose, reinforced concrete beams were made and sensors were attached both on the surface of the beams and inside steel. Two types of sensors were used to detect strain on the beams and steel : fiber bragg grating sensors, electric resistance strain sensors. So fatigue test is done with measuring strain of specimen. In addition, this experiments estimates the optimum deflection curve that converts strain curve data measured by FBG sensors into deflection.

  • PDF