• Title/Summary/Keyword: Fatigue curve

Search Result 478, Processing Time 0.025 seconds

A Study on the Flexural Fatigue Behavior of R/C Beams Repaired with Concrete-Polymer Composites (유기 및 유기재료로 보수된 R/C 보의 휨 피로거동에 관한 연구)

  • 심종성;황의승;배인환;이은호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.233-241
    • /
    • 1995
  • In this thesis, the fatigue tests were performed on a series of R /C beams repaired with co& crete-lmlyrner composites to investigate the fatigue bahavior. The three point loading system is used in the fatigue tests. In these tests, relations between the repeated loading cycles and mid-span deflections, number of repeated loading cycles when repaired beams were fractured, the bonding performance of repair materials were observed. On this basis, the mid-span deflections, the crack growth and failure mode of repaired R /C beams were studied. A S-N curve was drawn to present the fatigue strength of repaired beams. From the test results, it was shown that behavior of R /C beams repaired with polymer-cement series were very sirnillar to control beam about bonding performance, mid-span deflections and fatigue strength according to S-N curve drawn by the regression anlysis on the fatigue test results.

Development of Ergonomic Backrest for Office Chairs

  • Kim, Chang Yong;Song, Gyung Yong;Jang, Yeon Sik;Ko, Hyo Eun;Kim, Hee Dong;Park, Gemus;Hwang, Jung Bo;Jung, Hwa Shik
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.151-165
    • /
    • 2015
  • Objective: This study aims to develop and scientifically investigate the efficacy of the Spine S-curve Reactive Backrest that responds to the spine curvature of the user when seated, and maintains and enhances the natural S-curve of the lower back, thereby helping to relieve fatigue, correct posture and prevent spine deformities. Background: The focus of current development, design guidelines and/or standards for office chairs is mainly placed on the chair's dimensions, incline angle, adjusting features and lumbar support. Research and development was called for developing a chair backrest that maintains and improves the S-curve of the full spine. Method: The Spine S-curve Reactive Backrest was ergonomically designed to maintain correct posture and enhance user comfort. When leaned on, the backrest responds to the user's spine line and the whole lower back sits closely against the backrest, thereby aligning the user's lower back and backrest as one to maintain and improve the natural S-curve formation of the spine. In order to evaluate the efficacy of the newly designed chair (new design) and the comparison target (chair), five male college students of standard body type with normal spine curvature were selected as test subjects, and a motion analyzer and electromyography were utilized to measure S-curve and erector spinae muscle activity when seated. Results: The spine S-curve was better maintained and improved when sitting in the new design than in the comparison chair. Particularly notable was the greater displacement gap of the thoracic spine than the cervical spine, and also that of the lumbar more than the thoracic spine, with the increase of the backrest tilting angle. Furthermore, the electromyogram results showed the new design caused a lower fatigue level of the erector spinae muscles compared to the comparison chair, and also earned a higher preference in the subjective opinion results. Conclusion: The newly designed chair in this study responds to the user's spine curvature and maintains and enhances the lower back's natural S-curve, and thereby relieves fatigue, promotes better posture, and helps to prevent spine deformities better than existing office chairs. There is a need to widely introduce and supply this new design. Application: The new design is applicable to office and student chairs, and is expected to improve concentration and work efficiency.

Ultrasonic Fatigue Test for a High Strength Steel Plate (고장력 강판의 초음파 피로시험)

  • Yeom, Hyunho;Jung, Yongchan;Kim, Chayeong;Kang, Ki-Young;Lee, Moon Gu;Hong, Min-Sung;Jeon, Yongho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.589-593
    • /
    • 2015
  • The demand of high cycle fatigue behavior on plate material is increasing because of its various applications. However, the high-cycle fatigue life data of the plate material is very rare compared to the rod material. Thus, in this study, a plate specimen is designed for the ultrasonic fatigue test because it is time efficient as compared to the conventional fatigue test. To apply the ultrasonic fatigue test, the specimen design is required to resonate at 20 kHz. Therefore, the dynamic elastic modulus was determined by measuring the resonance frequency with a piezoelectric element and laser doppler vibrometer (LDV). As a result, the plate specimen is designed and demonstrated using the ultrasonic fatigue testing machine. The ultrasonic fatigue test results were compared with the hydraulic fatigue test results.

Fatigue Properties of Copper Foil and the Evolution of Surface Roughness

  • Oh, Chung-Seog;Bae, Jong-Sung;Lee, Hak-Joo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.57-62
    • /
    • 2008
  • The aim of this investigation was to extract the fatigue properties at the designated fatigue life of copper foil and observe the mean stress and stress amplitude effects on both the fatigue life and the corresponding surface morphology. Tensile tests were performed to determine the baseline monotonic material properties of the proportional limit and ultimate tensile strength. Constant amplitude fatigue tests were carried out using a feedback-controlled fatigue testing machine. The mean stress and the stress amplitude were changed to obtain the complete nominal stress-life curves. An atomic force microscope was utilized to observe the relationship between the fatigue damage and the corresponding changes in surface morphology. A Basquin's exponent of-0.071 was obtained through the fatigue tests. An endurance limit of 122 MPa was inferred from a Haigh diagram. The specimen surface became rougher as the number of fatigue cycles increased, and there was a close relationship between the fatigue damage and the surface roughness evolution.

Prediction of Gear Bending Fatigue Life of Electro-mechanical Actuator for Aircraft Through Finite Element Analysis

  • Kim, Taehyung;Seok, Taehyeon;Kwon, Soon-hyeong;Lee, Byung-ho;Kwon, Byung-gi;Kwon, Jun-yong;Cheong, Seong-kyun
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.58-67
    • /
    • 2020
  • In this study, finite element fatigue analysis combined with a fatigue correlation factor is proposed to predict the bending fatigue life of a gear in an electro-mechanical aircraft actuator. First, stress-life curves are obtained for the gear material via a round bar fatigue test. Subsequently, stochastic stress-life (P-S-N) curves are derived for 50% and 1% failure probabilities, separately. The curves are applied to the fatigue analysis model of a single gear tooth, and the effect of the fatigue correction factor is analyzed. The analytical P-S-N curves reflecting the fatigue correction factor matched the experimental data. This shows that the analytical fatigue life is reliable and that the analysis technique is effective.

A complete integrity assessment of welded connections under high and low cycle fatigue followed by fracture failure

  • Feng, Liuyang;Liu, Tianyao;Qian, Xudong;Chen, Cheng
    • Steel and Composite Structures
    • /
    • v.43 no.4
    • /
    • pp.465-481
    • /
    • 2022
  • This paper presents a comprehensive integrity assessment of welded structural components, including uniform high- and low-cycle fatigue assessment of welded plate joints and fatigue-induced fracture assessment of welded plate joints. This study reports a series of fatigue and fracture tests of welded plate joints under three-point bending. To unify the assessment protocol for high- and low-cycle fatigue of welded plate joints, this study develops a numerical damage assessment framework for both high- and low-cycle fatigue. The calibrated damage material parameters are validated through the smooth coupon specimens. The proposed damage-based fatigue assessment approach describes, with reasonable accuracy, the total fatigue life of welded plate joints under high- and low-cycle fatigue actions. Subsequently, the study performs a tearing assessment on the ductile crack extension of the fatigue-induced crack. The tearing assessment diagram derives from the load-deformation curve of a single-edge notched bend, SE(B) specimen and successfully predicts the load-crack extension relation for the reported welded plate joints during the stable tearing process.

Effect of matrix on fatigue strength of carbon fiber composite materials (탄소섬유강화 복합재료의 피로강도에 미치는 모재의 영향)

  • 유승원
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.113-121
    • /
    • 1992
  • In this study, the variation of fatigue strength in CF/PEEK and CF/EPOXY, the matrix and interfacial strength of which differ from each other, has been studied from the viewpoint of microfracture behavior. The results obtained are as follows; According as the fatigue strength moves from the lower cycle range to the higher cycle range, that of CF/PEEK shows higher curve than that of CF/EPOXY does. In the early stage of fatigue life, the characteristic of fatigue crack in CF/PEEK is mainly the fracture of longitudinal fiber, while that in CF/EPOXY is the fracture of transverse fiber. The difference of fatigue strength in these materials can be explained by the fracture criteria of transverse fiber and longitudinal fiber.

  • PDF

A Study on the fatigue strength analysis of the welded joints in ship hull construction (선체구조의 용접이음부의 피로강도 해석법에 관한 연구)

  • 엄동석;강성원;이성구;김원범
    • Journal of Welding and Joining
    • /
    • v.10 no.4
    • /
    • pp.259-267
    • /
    • 1992
  • In this report, a method to predict the fatigue strength in welded structure member of ship construction is studied considering the effects of statistical characteristics of mild steels and weld toe shapes on the fatigue crack initiation life. The fatigue test under pulsating bending load is carried out with the model specimens of the web frame in double bottom of ship hull. The propriety of the fatigue life curve with probability of failure in the transverse strength members of ship hull construction is confirmed by the comparison with the results of fatigue test on the model of the various transverse strength members.

  • PDF

Fatigue reliability analysis of welded joints of a TLP tether system

  • Amanullah, M.;Siddiqui, N.A.;Umar, A.;Abbas, H.
    • Steel and Composite Structures
    • /
    • v.2 no.5
    • /
    • pp.331-354
    • /
    • 2002
  • Tethers of Tension Leg Platform (TLP) are a series structural system where fatigue is the principal mode of failure. The present study is devoted to the fatigue and fatigue fracture reliability study of these tethers. For this purpose, two limit state functions have been derived. These limit state functions are based on S-N curve and fracture mechanics approaches. A detailed methodology for the reliability analysis has then been presented. A sensitivity analysis has been carried out to study the influence of various random variables on tether reliability. The design point, important for probabilistic design, is located on the failure surface. Effect of wind, water depth, service life and number of welded joints are investigated. The effect of uncertainties in various random variables on tether fatigue reliability is highlighted.

The Effect of Plastic Working on the Membrane Fatigue Life (소성가공이 멤브레인 피로 수명에 미치는 영향)

  • Yoon I.S.;Kim Y.K.;Kim J.K.
    • 한국가스학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.193-198
    • /
    • 2005
  • An investigation was made on the fatigue characteristics of type 304 stainless steel membrane manufactured by plastic working. To investigate the effect of plastic deformation, tests were performed with 5 types of specimens having different amount of plastic deformation. Fatigue tests were executed under both room and LNG temperatures ($-162^{\circ}C$). All the test results were compared with the fatigue data provided by RPIS(Recommended Practice for Inground LNG Storage Tank). On the basis of these results, it was confirmed that RPIS's design fatigue curve could be applied to evaluate fatigue lift of KOGAS membrane manufactured by pressing.

  • PDF