• Title/Summary/Keyword: Fast-Switching

Search Result 560, Processing Time 0.025 seconds

Analysis of a Three Phase PWM AC/DC Converter With Input Current Waveform and Power Factor Correction (입력 전류 파형과 역률 개선 제어기법에 의한 3상 PWM 컨버터 해석)

  • 이수흠;배영호;최종수;백종현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • This paper describes to control system for AC to DC converter which has been widely used to power source in industrial factory and domestics. In this paper, three-phase PWM AC to DC Boost converter that operates with unity power factor and sinusodial input line currents is presented. The current control of this converter is based on the predicted current control strategy with fixed switching frequency and the line currents track to reference currents within one sampling time interval. By using this control strategy low ripples in the output current and the voltage as well as fast dynamic response are achieved with small dc link capacitance employed.ployed.

  • PDF

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

A Study on the Surge Protection Device for Computer Networks by International Standards (국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발에 관한 연구)

  • Park, Dae-Won;Seo, Hwang-Dong;Song, Jae-Yong;Han, Joo-Sup;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.277-280
    • /
    • 2005
  • This paper dealt with the development of a surge protection device (SPD) that can protect high speed computer network devices from overvoltages caused by switching operations or lightning surges. The designed SPD is a form of hybrid circuit which is composed of a gas tube having large current diverting capability, high response bi-directional avalanche diodes, and fast recovery diodes to reduce insertion loss on high frequency domain. Surge protection and signal transmission characteristics of the fabricated SPD was tested according to the international standards, IEC 61000-4-5 and IEC 61643-21. From the test results, the SPD is satisfied with the international standards and the high cut-off frequency was 204MHz. Also, the SPD showed a good performance without an insertion loss on a field test of 100Mbps class Local Area Network

  • PDF

A Study on The Broken Rotor Bars in Induction Motor and The Controll Characteristics in Inverter (유도전동기 로터바의 손상과 인버터 제어특성에 관한 연구)

  • Kim K.W.;Kwon J.L.;Lee K.J.;Choi K.S.;Lee H.S.;Chang S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.464-466
    • /
    • 2001
  • The advantage of the squirrel cage induction motor is the brushless rotor. This advantage for operation and maintenance turns out to be a disadvantage for the detection of the cage rotor bar and endring defects, which means that the detection of cage faults is due to the measurement and analysis of only the stator input signals. The monitoring task in an inverter drive is complicated mainly because the voltage and current waveforms are nonsinusoidal and the high dv/dt values from fast switching inverterd distort the measurements. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA).

  • PDF

Effective ROM Compression Methods for Direct Digital Frequency Synthesis (직접 디지털 주파수 합성을 위한 효율적인 ROM 압축 방법)

  • 이진철;신현철
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.9
    • /
    • pp.536-542
    • /
    • 2004
  • An architecture of direct digital frequency synthesizers (DDFS) is studied in this paper The Direct digital frequency synthesizers (DDFS) provide fast frequency switching with high spectral purity and are widely used in modern spread spectrum wireless communication systems. ROM-based DDFS uses a ROM lookup table to store the amplitude of a sine wave. In this paper, we suggest three new techniques to reduce the ROM size. One new technique uses more number of hierarchical levels in ROM structures. Another techniques use simple interpolation techniques combined with hierarchical ROM structures. A 12 bit sine wave is generated by using these techniques. Experimental results show that the new proposed techniques can reduce the required ROM size by up to 24%, when compared to that of a resent method[1].

Analysis of Dynamic Characteristics for High speed Plunger-type Solenoid (고속 플런저형 솔레노이드의 동특성 해석)

  • 백동기;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 1997
  • In this paper, numerical analysis of dynamic characteristics for the plunger-type solenoid was used for a high speed solenoid valve with fast switching is discussed. The theoretic analysis of the electromagnetic field including eddy currents in the solenoid is studied by using permeance. The optimum value of design parameters which are a mass and an area of the plunger, a source voltage, a elastic modulus of the spring, a stroke, a number of turns, are obtained by the results of the investigation on effect of a parameter on others. And dynamic characteristics of acting solenoid that is the variation of magnetic force, displacement, solenoid current are investigated.

  • PDF

Optimum Design of Integer and Fractional-Order PID Controllers for Boost Converter Using SPEA Look-up Tables

  • Amirahmadi, Ahmadreza;Rafiei, Mohammadreza;Tehrani, Kambiz;Griva, Giovanni;Batarseh, Issa
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.160-176
    • /
    • 2015
  • This paper presents a method of designing optimal integer- and fractional-order proportional-integral-derivative (FOPID) controllers for a boost converter to gain a set of favorable characteristics at various operating points. A Pareto-based multi-objective optimization approach called strength Pareto evolutionary algorithm (SPEA) is used to obtain fast and low overshoot start-up and dynamic responses and switching stability. The optimization approach generates a set of optimal gains called Pareto set, which corresponds to a Pareto front. The Pareto front is a set of optimal results for objective functions. These results provide designers with a trade-off look-up table, in which they can easily choose any of the optimal gains based on design requirements. The SPEA also overcomes the difficulties of tuning the FOPID controller, which is an extension to the classic integer-order PID controllers and potentially promises better results. The proposed optimized FOPID controller provides an excellent start-up response and the desired dynamic response. This paper presents a detailed comparison of the optimum integer- and the fractional-order PID controllers. Extensive simulation and experimental results prove the superiority of the proposed design methodology to achieve a wide set of desired technical goals.

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

A Dimming Method for the UHD Broadcast LED Lighting (UHD 방송용 LED 조명의 조도제어 방법)

  • Shin, Dong-Seok;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.8-18
    • /
    • 2015
  • This paper proposes a dimming method and a hybrid LED driving circuit suitable for the ultra high definition (UHD) broadcasting. There are major two problems during the dimming control for traditional LED broadcast lightings; one is a flicker that occurred when camera filming to these lightings, and the other is that linear control is impossible for LED luminous intensity under 10% due to LED electrical characteristics. The proposed dimming method and the driving circuit are designed to solve two problems simultaneously. For high level dimming control region from 10 to 100%, the analog control method was applied to the switching regulator constructed by MOSFET operated in the saturation region. For low level dimming control region under 10%, the fast PWM control method with the linear regulator constructed by MOSFET in the ohmic region was used. We verified experimentally that the dimming method is able to control the luminous intensity linearly from 1 to 100% and the flicker disappears on images taken by the charge coupled device (CCD) and the complementary metal oxide semiconductor (CMOS) cameras. Therefore, the proposed method is suitable for the UHD broadcasting.

The Analysis of Priority Output Queuing Model by Short Bus Contention Method (Short Bus contention 방식의 Priority Output Queuing Model의 분석)

  • Jeong, Yong-Ju
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.2
    • /
    • pp.459-466
    • /
    • 1999
  • I broadband ISDN every packet will show different result if it would be processed according to its usage by the server. That is, normal data won't show big differences if they would be processed at normal speed. But it will improve the quality of service to process some kinds of data - for example real time video or voice type data or some data for a bid to by something through the internet - more fast than the normal type data. solution for this problem was suggested - priority packets. But the analyses of them are under way. Son in this paper a switching system for an output queuing model in a single server was assumed and some packets were given priorities and analysed. And correlation, simulating real life situation, was given too. These packets were analysed through three cases, first packets having no correlation, second packets having only correlation and finally packets having priority three cases, first packets having no correlation, second packets having only correlation and finally packets having priority and correlation. The result showed that correlation doesn't affect the mean delay time and the high priority packets have improved mean delay time regardless of the arrival rate. Those packets were assumed to be fixed-sized like ATM fixed-sized cell and the contention strategy was assumed to be short bus contention method for the output queue, and the mean delay length and the maximum 버퍼 length not to lose any packets were analysed.

  • PDF