• 제목/요약/키워드: Fast-Switching

검색결과 560건 처리시간 0.026초

Fast Fringe-field-switching Liquid Crystal Cell with a Protrusion Structure

  • Park, Sung Il;Choi, Sun-Wook;Kim, Ki-Han;Song, Dong Han;Shim, Yu Ri;Lee, Sun Yong;Kang, Sung Gu;Yoon, Jeong Hwan;Kim, Byeong Koo;Yoon, Tae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제17권2호
    • /
    • pp.200-204
    • /
    • 2013
  • We propose a cell structure for the fast switching of liquid crystals by the fringe field. By forming protrusion between patterned electrodes, we can obtain enhancement of response time. The protrusion reduces the effective cell gap, with which a fast response time can be realized. There is little decrease in the transmittance because the protrusion is located between patterned electrodes. We confirmed that the total response time can be decreased by 33% with little loss of the transmittance by optimizing the shape of the protrusion structure.

패스트푸드점의 로하스 이미지, 고객만족, 전환장벽 및 재방문의도의 영향관계에 관한 연구 (A Study on the Influence Relationship of LOHAS Image, Customer Satisfaction, Switching Barrier, and Revisit Intention to Fast Food Store)

  • 이승희;정연교;김혜경;조영준
    • 디지털융복합연구
    • /
    • 제6권4호
    • /
    • pp.113-121
    • /
    • 2008
  • This paper aimed to exam relationship of lohas image, customer satisfaction, switching barrier, revisit intention to fast food store. To accomplish this purpose, this study examined previous studies and summmarized. 400 questionaries were distributed to the people living in Daegu/Gyeong-Buk 381 questionaries were obtained and 331 data were analyzed by frequencies, correlation, multiple regression, The results of this study are as follows; First, it is shown that lohas image have a positive influence on the customer satisfaction(p<0.001). Second, it is shown that lohas image have a positive influence on the switching barrier(p<0.001). Third, it is shown that customer satisfaction have a negative influence on the switching barrier(p<0.57). Fourth, it is shown that lohas image have a positive influence on the revisit intention(p<0.05). Fifth, it is shown that customer satisfaction have a positive influence on the revisit intention(p<0.001). Sixth, it is shown that switching barrier have a positive influence on the revisit intention(p<0.001). This study, however, have limitations in obtained sample and area. The future study should consider these limitations to improve model applicability in practice.

  • PDF

A Novel Fast-Switching LCD with Dual-Domain Bend Mode

  • Satake, Tetsuya;Kurata, Tetsuyuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.209-212
    • /
    • 2004
  • A navel fast-switching LCD with dual-domain bend (DDB) mode is described DDB alignment is achieved using antiparallel-rubbed cell filled with chiral-doped LC. Initial alignment is mono-domain 180-degree twist. Tilt direction is controlled by oblique electric field to be counter direction in each domain Twist-to-DDB deformation occurs continuously so that DDB mode does not require high-voltage initialization which is inevitable in Optically Compensated Bend (OCB) mode. DDB gives wide and symmetric viewing angle in contrast to mono-domain bend formed from 180-degree twist showing strong asymmetry.

  • PDF

대전력 펄스의 고속 스위칭 연구 (A Study on Fast Switching System for High Power Pulse)

  • 이석우;이영호;하성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1869-1871
    • /
    • 1998
  • In this paper, we designed and fabricated a fast switching system for high power pulse. This system consists of a voltage conversion circuit, high voltage charging circuit, trigger circuit, and discharging circuit. Especially discharging line is designed by strip-line for low inductance and resistance. The experimental result is that current slew rate of the system is 6.67kA/86ns and this result is fully qualified for initiating EBW or EFI

  • PDF

154KV 변압기의 계통개폐 급준파 전압특성 연구 (A Study on the fast-rising switching surges charateristics in the 154KV transformers)

  • 조연옥;김익수;김중연;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.907-910
    • /
    • 1992
  • This paper deals with the mesurement and the analysis by means of EMTP simulation for the fast-rising switching surges. The fast-rising surges having up to 180ns of front time and 3.42 p.u of peak value were measured at the 154KV substations. The fast-rising surges are expected to cause electric breakdown because the penetrating surges to the transformers result in the higher stress in the winding end than the average stress along the winding.

  • PDF

Retardation Free In-plane Switching Liquid Crystal Display with High Speed and Wide-view Angle

  • Kang, Wan-Seok;Moon, Je-Wook;Lee, Gi-Dong;Lee, Seung-Hee;Lee, Joun-Ho;Kim, Byeong-Koo;Choi, Hyun-Chul
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.161-167
    • /
    • 2011
  • In this paper, we propose an in-plane switching (IPS) mode for liquid crystal displays (LCDs) that, in principle, is free of retardation of the LC cell. Basically, the optical configuration of the LC cell consists of an A-plate and an LC layer for switching between the dark and bright states. We could achieve a fast response time compared with the conventional in-plane LC cell because the free retardation condition of the proposed LC cell enables us to reduce the cell gap even by quarter-wave retardation without any change of the optimized LC material in the transmissive mode. Experiments for verification of the proposed in-plane switching LC cells have shown a significant reduction of the rising time and falling time simultaneously due to the small cell gap. Furthermore, we also proposed an optical configuration for wide viewing property of the retardation free IPS LCD by applying the optical films. We proved the wide-view property of the retardation free IPS LCD by comparing its optical luminance with the calculated optical property of the conventional IPS LCD.

EV와 NEV 겸용 50kW급 고효율 모듈형 급속충전기 개발 (Development of 50kW High Efficiency Modular Fast Charger for Both EV and NEV)

  • 김민재;김연우;요스 프라보우;최세완
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.373-380
    • /
    • 2016
  • In this paper, a 50-kW high-efficiency modular fast charger for both electric vehicle (EV) and neighborhood electric vehicle (NEV) is proposed. The proposed fast charger consists of five 10-kW modules to achieve fault tolerance, ease of thermal management, and reduce component stress. Three-level topologies for both AC-DC and DC-DC converters are employed to use 600V MOSFET, resulting in ease of component selection and increase in switching frequency. The proposed three-level DC-DC converter with coupled inductor and its hybrid switching method can reduce the circulating current under wide output voltage range. A 50-kW prototype of the proposed fast charger was developed and tested to verify the validity of the proposed concept. Experimental results show that the proposed fast charger achieves a rated efficiency of 95.2% and a THD of less than 3%.

Power Loss Analysis of Interleaved Soft Switching Boost Converter for Single-Phase PV-PCS

  • Kim, Jae-Hyung;Jung, Yong-Chae;Lee, Su-Won;Lee, Tae-Won;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.335-341
    • /
    • 2010
  • In this paper, an interleaved soft switching boost converter for a Photovoltaic Power Conditioning System (PV-PCS) with high efficiency is proposed. In order to raise the efficiency of the proposed converter, a 2-phase interleaved boost converter integrated with soft switching cells is used. All of the switching devices in the proposed converter achieve zero current switching (ZCS) or zero voltage switching (ZVS). Thus, the proposed circuit has a high efficiency characteristic due to low switching losses. To analyze the power losses of the proposed converter, two experimental sets have been built. One consists of normal devices (MOSFETs, Fast Recovery (FR) diodes) and the other consists of advanced power devices (CoolMOSs, SiC-Schottky Barrier Diodes (SBDs)). To verify the validity of the proposed topology, theoretical analysis and experimental results are presented.

Electro-optical devices from polymer-stabilized liquid crystals with molecular shape polarity

  • Kim, Sang-Hwa;Chien, Liang Chy;Komitov, Lachezar
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.839-842
    • /
    • 2004
  • We present a fast-switching electro-optical device based on flexoelectro-optic effect in short pitch cholesterics oriented in uniform lying helix texture. The device has two operating modes: amplitude and phase modulation mode. The amplitude modulation mode is a fast in-plane switching of the device optic axis that enables to achieve a high percent of modulation of the transmitted light intensity whereas the phase mode gives a continuous change of the refractive index and thus of the phase shift of the transmitted light. By using a small concentration of diacrylate monomer and selecting the illumination conditions we have been able to create a inhomogeneous polymeric network mostly localized at both substrate surfaces and stabilize the two switching modes.

  • PDF

Ultra-fast Adaptive Frequency-controlled Hysteretic Buck Converter for Portable Devices

  • Kim, Kwang-Ho;Kong, Bai-Sun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.615-623
    • /
    • 2016
  • The paper describes a hysteretic buck converter including a differentiator and an adaptive hysteresis window controller. Differentiating the feedback signal achieves ultra-fast switching of the buck converter. The adaptive hysteresis window control allows a monotonous operation with predictable noise spectrum, and gives way to efficient design for variable supply and output voltages. The measurement results in a $0.13-{\mu}m$ CMOS process indicated that the switching frequency became double times higher, and the voltage ripple was reduced by up to 69%. They also indicated that the normalized switching frequency variation was reduced by 74% with variable $V_{DD}$ and by 63% with variable $V_{OUT}$. The power efficiency was improved by 3.5% depending on loading condition.