• 제목/요약/키워드: Fan noise

검색결과 477건 처리시간 0.025초

화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

전자기 가진 원 저감에 의한 BLDC Fan Motor의 공진 소음 저감에 관한 연구 (Study on the Noise Reduction of BLDC Fan Motor by the Diminution of the Electro-Magnetic Exciting Source)

  • 신현정;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.857-860
    • /
    • 2006
  • It is important to diminish noise source of an electric motor used in appliances. We studied on the noise reduction of BLDC motor to drive a fan. Especially, this study was focused on detent torque caused by interaction between a permanent magnet of rotor and groove in stator. This source and rotating system brought about a resonance. This paper showed that the higher harmonic component of this torque had a main factor to lessen noise. So, we had designed new magnets with shape like a peanut and pseudo-sinusoidal flux density for low-noise BLDC motor in refrigerator.

  • PDF

다중-레퍼런스/다중-출력 FXLMS 알고리즘에 의한 UPS 팬 소음저감 특성해석 (Characteristin Analysis of UPS Fan Noise Reduction by Multiple-Referedce/Multiple-Output FXLMS Algorithm)

  • 이승요;조준석;최규하
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.589-600
    • /
    • 1999
  • 사무실에서 사용되는 소용량 무정전진원 장치(UPS : Uninterruptible Power Supply)는 대부분의 소음이 냉각팬을 통하여 발생되고 있는데, 이와 같이 장치의 여러 방향으로 방사되는 소음의 능동적 소음제어를 위해서는 FXLMS(Filtered-x LMS) 알고리즘에 기초를 둔 다중채널 방식의 FXLMS(multiple-channel FXLMS) 알고리즘의 사용이 적당하다. 본 논문에서는 사무실에서 주로 사용되는 소용량 UPS의 소음 발생 특성을 분석하고 다중채널 방식 MRMO(Multiple-Reference/Multiple-Output) FXLMS 알고리즘을 적용하여 방사상으로 전파되는 UPS의 소음을 저감시키기 위한 능동 소음 제어를 수행하고 이의 소음저감 특성을 고찰한다.

  • PDF

Prediction of Specific Noise Based on Internal Flow of Forward Curved Fan

  • Sasaki, Soichi;Hayashi, Hidechito;Hatakeyama, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.80-91
    • /
    • 2009
  • In this study, a prediction theory for specific noise that is the overall characteristic of the fan has been proposed. This theory is based on total pressure prediction and broadband noise prediction. The specific noises of two forward curved fans with different number of blades were predicted. The flow around the impeller having 120 blades (MF120) was more biased at a certain positions than the impeller with 40 blades (MF40). An effective domain of the energy conversion of MF40 has extended overall than MF120. The total pressure was affected by the slip factor and pressure loss caused by the vortex flow. The suppression of a major pressure drop by the vortex flow and expansion of the effective domain for energy conversion contributed to an increase in the total pressure of MF40 at the design point. The position of maximum relative velocity was different for each fan. The relative velocity of MF120 was less than that of MF40 due to the deviation angle. The specific noise of MF120 was 2.7 dB less than that of MF40 due to the difference in internal flow. It has been quantitatively estimated that the deceleration in the relative velocity contributed to the improvement in the overall performance.

PC의 진동/소음 저감을 위한 쿨링팬의 동흡진장치 및 절연장치의 개발 (A Development of the Vibration Absorber and Damper for Vibration and Noise Reduction of the Computer)

  • 정진태;정원영;이규호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.370-375
    • /
    • 2009
  • The purpose of this study is to reduce the vibration of the computer by developing the vibration absorber and damper. The eccentricity of the cooling fan causes the vibration of the computer. We designed the material properties of the vibration absorber by FEM model within operation frequencies of the cooling fan. We experiment the overall analysis and system analysis. The vibration of cooling fan is measured by using a laser vibrometer. The result shows that the proposed vibration absorber and damper reduce the vibration of the computer.

  • PDF

상용 CFD코드를 이용한 횡류홴 공력소음 특성 해석 (Analysis of the aeroacoustic characteristics of cross-flow fan using commercial CFD code)

  • Jeon, Wan-Ho;Gi, Jeong-Mun
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.334.1-334
    • /
    • 2002
  • In this study, a cross-flow fan system used in indoor unit of the split-type air conditioner is analyzed by computational simulation. A commercial CFD code - Fluent - is used to calculate the performance and its unsteady flow characteristics. The unsteady incompressible Wavier-Stokes equations are solved using a sliding mesh technique on the interface between rotating fan region and the outside. The acoustic pressure is calculated by using Ffowcs-Williams and Hawkings equation. (omitted)

  • PDF

환기팬 시스템의 소음특성과 저감에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System)

  • 김덕한;이동훈;권혁정;김동윤;이종석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

테일홴 성능시험장치의 운용과 진동특성 (The Operation and Vibration Characteristics of Tail-fan Performance Test System)

  • 송근웅;김준호;강희정;이욱;심정욱
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.421-428
    • /
    • 2005
  • This paper described operation and vibration characteristics of a 'tail-fan' anti-torque performance test system. KARI (Korea Aerospace Research Institute) developed a 'tail-fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the tail-fan. The performance test-rig consists of driving, supporting and rotating parts. In the process of the performance test, firstly, operation test of the test-rig were carried out to verify design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for the performance test, vibration test were carried out using accelerometers on tail gear box. The performance test conditions of the tail-fan to avoid a resonance were found from the fan-plot and vibration test results. The tail-fan performance tests were well done safely.

벽걸이에어컨의 원심홴에 대한 과도진동 규명 및 저감 (Transient Vibration Identification and Reduction of a Centrifugal Fan for a Wall-installed Air-conditioner)

  • 김민성;임종혁;정진태
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.383-390
    • /
    • 2016
  • In this paper, experiment and dynamics simulations were carried out to identify and reduce the out-of-plane vibration that occurs in a centrifugal fan of an air conditioner installed to a wall. In a wall-installed air conditioner, large space between a case and heat exchanger is often required for the fan to avoid the collision with the case and exchanger. This large space hinders the slim design of the air conditioner even if air conditioner market demands a slim air conditioner. In the present study, in order to determine the cause of the vibration in the centrifugal fan, the out-of-plane vibration and the physical properties were investigated, and the dynamic characteristics of the centrifugal fan were obtained by experiments. Based on these experiments, a dynamic simulation model was established to determine the cause of the out-of-plane vibration of the centrifugal fan. It was found that the main factor of out-of-plane vibration in the centrifugal fan is the axial misalignment between the centrifugal fan and the motor shaft.

필터보정역투영 CT 영상재구성방법에서 잡음 특성 (Noise Properties for Filtered Back Projection in CT Reconstruction)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.357-364
    • /
    • 2014
  • 전산화단층촬영장치의 영상재구성방법으로 필터보정역투영법이 광범위하게 사용되고 있다. 평행빔과 부채살빔의 재구성에 사용되는 투영에 잡음이 포함되었을 때 재구성 된 영상의 잡음을 살펴보았다. 평행빔과 부채살 구조에서 각각 360개, 720개의 투영으로 $512{\times}512$ 크기로 Visual C++을 이용하여 영상재구성하였고, 원본 Shepp-Logan 두부 모형을 매우 잘 복원한다는 것을 확인하였다. 필터보정역투영법의 현실적인 접근(유한한 투영 개수)으로 인해 입력 잡음이 없어도 영상재구성 과정에서 잡음이 발생하였다. 입력 잡음비 0.5% 이하에서 잡음이 빠르게 증가하기 때문에 CT 장치의 잡음 제거 기술 및 영상처리 기법의 개발이 필요할 것이다.