• Title/Summary/Keyword: Fan angle

Search Result 218, Processing Time 0.022 seconds

Some Relations Between the Geometric Parameters and Internal Flow Field Characteristics in Multiblade Fan/Scroll System (다익 홴/스크롤 시스템의 형상변수와 내부 유동장 특성과의 관계)

  • Maeng, Joo-Sung;Yoo, Dal-Hyun;Lee, Kwang-Ho;Park, ln-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1139-1147
    • /
    • 2000
  • This paper describes that the size of inactive zone can be directly applied to design multiblade fan/scroll system. From the experimental studies using a five hole pitot tube and smoke test, it is found that the size of inactive zone has linear relations with the mean velocity of impeller inlet and cut-off angle gives a great influences to the fan efficiency. For the practical design, a function related with geometric parameters(i.e. inner radius, cord length, cut-off clearance and cut-off angle) of fan/scroll system is suggested. By using these formulas, the size and distribution of inactive zone can be predicted without the measurements through the full domain, it can be possible to use them to know the efficiency improvement for new model designed.

Numerical Analysis on the Effect of Parameters that Affect the Flow Rate through the Tunnel with Jet Fan Ventilation System

  • Kim, Sa-Ryang;Hur, Nahmkeon;Kim, Young-Il;Kim, Ki-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.178-187
    • /
    • 2003
  • In this study, ventilation flow rate and pressure rise through a tunnel are simulated numerically using computational fluid dynamics (CFD) for various conditions such as roughness height of the surface of tunnel, swirl angle and hub/tip ratio of jet fan, and entrance and exit effects. By using a modified wall function, friction factor can be predicted with respect to the Moody chart within 10% of error for the circular pipe flow and 15% for the present tunnel. For more accurate design, the effect of the swirl angle and hub/tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan needs to be considered.

Study on Low noise, High Performance Automobile Cooling Fan Development Using Freewake and CFD Analysis (자유후류법과 CFD 해석을 통한 저소음 고효율 자동차용 냉각팬 개발에 관한 연구)

  • ;;Renjing Cao
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.847-847
    • /
    • 2004
  • Automobile cooling fans are operated with a radiator module. To design low noise, high performance cooling fan, radiator resistance should be considered in the design process. The system (radiator) resistance reduces axial velocity and increases effective angle of attack. This increasing effective angle of attack mechanism causes blade stall, performance decrease and noise increase. In this paper, To analyze fan performance, freewake and 3D CFD calculations are used To design high performance fan with consideration of system resistance, optimal twist concept is applied through momentum and blade element theory. To predict fan noise, empirical formula and acoustic analogy methods are used.

  • PDF

An Experimental Study on Performance and Flow Characteristics of Automotive Sirocco Fan (자동차용 시로코팬의 성능 및 유동특성에 관한 실험적 연구)

  • 유성연;이대웅
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.954-963
    • /
    • 2002
  • For the optimal design of an automotive blower system, effects of the scroll cut-off starting angle, the clearance between blade tip and bellmouth, and the scroll expansion angle on the performance of sirocco fan are investigated experimentally. Best performance is achieved at fan exposure ratio $\Deltae/r_c$,/TEX> =1.0, and clearance ratio $\DeltaeC/C=0.62. Flow characteristics inside sirocco fan are also studied by using LDV. Flow patterns in the inside of fan can be classified into three regions. Velocity vector has the same direction as rotational direction of fan at 0~$120^{\circ}$, toward the fan blades at 150~$180^{\circ}$, and opposite direction at 210~$330^{\circ}$. Turbulent intensity is relatively high near the cut-off edge in the scroll housing.

Performance Characteristics of In-Line Duct Fan Having Mixed Flow Impellers (혼류임펠러를 갖는 관류형팬의 성능특성)

  • Park, Jin-Wook;Lee, Chul-Hyung;Park, Wan-Soon;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2007
  • The performance of in-line duct fan depends on the design parameters of impeller and guide vane such as sweep back angle of impeller hub, guide vane angle etc. In this study four kinds of impellers having different sweep back angles, $0^{\circ}$, $17.5^{\circ}$, $35^{\circ}$, $52.5^{\circ}$ with 8 guide vanes, and different guide vane angles, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ were selected and their performance measured to investigate the effects of design parameters. The results show that both sweep back angle of impeller hub and the guide vane angle have large effect on the efficiency. Especially, it was found that the mixed flow impellers having sweep back angle between $17.5^{\circ}$ and $35^{\circ}$ gave good performances for in-line duct fan.

The Development of Turbo-Fan Blade for KTX (KTX용 터보팬 블레이드 개발)

  • Jang, Young-Min;Kwon, O-Woon;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.41-45
    • /
    • 2009
  • The new cooling fan for various parts & equipments of KTX is developed and evaluated to improve fan performance and durability. The characteristic curve of the developed fan is obtained according to KSB 6311 of performance test regulation. 70 degree of the installation angle of blade makes the fan to produce a maximum flow rate. This angle is found out through trial-error and is confirmed through the verification test. In order to improve the blade strength, the blade is produced by a draw forming. The adoption of AL50 reduces a fan weight by 6 kg. The new blade makes a static pressure 170 (mmAq), a discharge rate $140(m^3/min)$, a rotational speed 2886 (rpm) at the power 10 kw. which results 54% of the static pressure improvement relative to the original blade.

  • PDF

Numerical study on the Performance Improvement of the Sirocco Fan in a Range Hood (레인지 후드용 시로코 홴의 성능 향상을 위한 연구)

  • Park, Sang-Tae;Choi, Young-Seok;Park, Moon-Soo;Kim, Cheol-Ho;Kwon, Oh-Myoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.572-577
    • /
    • 2004
  • This paper presents numerical study on the performance improvement of the sirocco fan in a range hood. The performance of sirocco fan means a higher flowrate, a higher static pressure and a lower required motor power in a fixed geometry constraint. Various impeller geometric parameters, such as blade profile, blade diameter, blade thickness profile and blade exit angle, were investigated by numerically and the results were compared with each other to know the effects on the performance. In this approach, the volute geometry were fixed with the original shape. The numerical results show that the blade profile with airfoil shape and small exit blade thickness increases the performance. The blade exit angle shows optimum angle within a varied range. The efficiency of the optimized exit angle was about $10\%$ higher than the base blade exit angle and the static pressure was about $28\%$ higher at the flow coefficient 0.22.

  • PDF

A Numerical Study on the Effects of the Design Parameters upon Fan Performance and Noise (축류홴의 설계 변수가 홴의 성능과 소음에 미치는 영향의 수치적 연구)

  • 전완호;백승조;김창준;윤홍열
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.264-269
    • /
    • 2001
  • Axial fans are widely used in household electrical appliances due to their easy usage and high flow rate for cooling capacity. At the same time, the noise generated by these fans causes one of serious problems. In order to calculate the noise of a fan, we develop the software IFD - Intranet Fans Design. With this software we can design, analysis the performance and predict the noise of fan. The prediction model, which allowed the calculation of acoustic pressure at the blade passing frequency and it's higher harmonic frequencies, has been developed by Lowson's equation. To calculate the unsteady resultant force of the blade, time-marching free-wake method is used. The objective of this study is to calculate the effects of number of blades, rotating velocity, and sweep angle on the noise of fan..

  • PDF

A study for noise properties of Sirroco fan blades (시로코팬 블레이드의 소음특성연구)

  • 최한림;곽지호;송기선;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.257-263
    • /
    • 2001
  • The purpose of this study is to find the amount of contributions of each Sirroco fan parameter to noise and performance using experimental and numerical approaches. We made several fans and structures related to fan housing and fan for parameter study like inlet blade angle, outlet blade angle, inlet diameter, outlet diameter, blade shape. etc.. Numerical analysis was performed using commercial code (FANNOISE) for the part not to be possible to do experiment. Using these parameter study, We have found the way to reduce noise and improve performance of fan and had some useful data for designing low noise and high performance fan.

  • PDF

Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries (산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성)

  • Yun, Ji-Hun;Jeong, In-Guk;Yi, Chung-Seob;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.