Study on the Noise Reduction of BLDC Fan Motor by the Diminution of the Electro-Magnetic Exciting Source (전자기 가진 원 저감에 의한 BLDC Fan Motor의 공진 소음 저감에 관한 연구)

  • Shin, Hyun-Jung;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.857-860
    • /
    • 2006
  • It is important to diminish noise source of an electric motor used in appliances. We studied on the noise reduction of BLDC motor to drive a fan. Especially, this study was focused on detent torque caused by interaction between a permanent magnet of rotor and groove in stator. This source and rotating system brought about a resonance. This paper showed that the higher harmonic component of this torque had a main factor to lessen noise. So, we had designed new magnets with shape like a peanut and pseudo-sinusoidal flux density for low-noise BLDC motor in refrigerator.

  • PDF

Study on Noise Reduction of an Air Conditioner through Modification of Axial Flow Fans and Shrouds (축류팬 및 슈라우드 개선을 통한 공조기 저소음화에 대한 연구)

  • Kim, Chang-Joon;Yoon, Hong-Yeol;Jung, Young-Gyu;Park, Young-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.380-387
    • /
    • 2000
  • In this paper, a successful result of modification of an axial flow fan and a shroud for noise reduction of a window type air conditioner is presented especially in order to verify the importance of blade shape improvement and the searching for the optimal shape of shrouds. Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have special shapes. From the viewpoint of the shape in a shroud, several cases were examined and the particular value of a design parameter of the shroud was acquired to get the best noise reduction of an air conditioner. Through the application of the methods, the air conditioner became less noisy by 4.5 dB(A) in terms of air-borne noise produced only by the axial flow fan and consumed less energy by 20.9% compared to the current one.

  • PDF

A Development of the Vibration Absorber and Damper for Vibration and Noise Reduction of the Computer (PC의 진동/소음 저감을 위한 쿨링팬의 동흡진장치 및 절연장치의 개발)

  • Chung, Jin-Tai;Jung, Won-Young;Lee, Kyu-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.370-375
    • /
    • 2009
  • The purpose of this study is to reduce the vibration of the computer by developing the vibration absorber and damper. The eccentricity of the cooling fan causes the vibration of the computer. We designed the material properties of the vibration absorber by FEM model within operation frequencies of the cooling fan. We experiment the overall analysis and system analysis. The vibration of cooling fan is measured by using a laser vibrometer. The result shows that the proposed vibration absorber and damper reduce the vibration of the computer.

  • PDF

A Development of the Dynamic Absorber and Damper for Vibration and Noise Reduction of the Personal Computer (PC의 진동/소음 저감을 위한 쿨링홴의 동흡진장치 및 절연장치의 개발)

  • Jung, Won-Young;Lee, Kyu-Ho;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.339-345
    • /
    • 2011
  • The purpose of this study is reduction the vibration of the personal computer by developing the vibration absorber and damper. The eccentricity of the cooling fan causes the vibration of the computer. We designed the material properties of the vibration absorber and damper by FEM model within operation frequencies of the cooling fan. We experiment the overall analysis and system analysis by using a laser vibrometer. The result shows that the proposed dynamic absorber and damper reduce the vibration of the personal computer.

Experimental Study of Cooling Fan Performance Analysis and Shroud Characteristics for an Excavator (굴삭기 냉각팬 성능해석 및 슈라우드 특성에 대한 실험적 연구)

  • Lee, Jae-Seok;Chung, Kyung-Nam;Kim, Jin-Young;Lee, Tae-Kyung;Kang, Jeong-Won;Shim, Jae-Koo;Son, Deuk-Kyun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2597-2602
    • /
    • 2007
  • In this paper, the performance analysis is experimentally carried out in order to select the best cooling fan and shroud considering both cooling performance and noise reduction. 4 cooling fans have been tested in the fan tester and the real excavator. In order to obtain the performance of the cooling fans, flow capacity has been estimated by measuring flow velocity using a hot wire anemometer, and noise radiation has been also measured to estimate the fan noise. Characteristics of a box-type and a streamlined shroud have been examined by changing the immersion depth of cooling fans. Based upon the results, the best cooling fan is selected. Finally, the criterion to select the best cooling fan has been set up.

  • PDF

A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner (청소기의 공력소음 특성 파악 및 저소음화에 관한 연구)

  • 전완호;백승조;김창준;허남건
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.633-638
    • /
    • 2002
  • The vacuum cleaner that has no dust bag generates very high level annoying noise. The dominant noise source is the 2$\^$nd/ BPF tone of the rotating impeller. In order to reduce the noise, we identify the acoustic characteristics and reduce the noise of the vacuum cleaner and centrifugal fan. The resonance phenomenon is observed in blade passages and we found out that the resonance frequency is very close to the 2$\^$nd/ BPF. In order to reduce this high-level peak noise, new impeller is designed in this paper. The trailing edge of new impeller is inclined and this makes the flow interactions between the rotating impeller and the stationary diffuser vane occurs with some phase shift. The performance of new impeller is similar to the old one but the overall SPL is reduced about 3.6dBA. The SPL of BPF is reduced about 6dBA and 2$\^$nd/ BPF is reduced about 20dBA. The vacuum cleaner, which uses newly developed centrifugal fan, generate more comfortable noise than the old model and the strong tonal sound was dramatically reduced.

  • PDF

A Study of AC Generator Noise Reduction Characteristics of Automobile Using Experimental Analysis (실험적 해석을 통한 차량용 교류발전기 소음 저감 특성 연구)

  • 김대원;신중호
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.112-121
    • /
    • 1998
  • In this report, Experimental analysis for main factors and analyzing methods of electro-magnetic noise and no loading noise was conducted because of noise of AC generator, which is peripheral equipment by reduction of engine noise that would be the main cause of vehicle radiation noise. In addition, This is intended to suggest the noise reduction development basis of AC generator for actual fan and electro-magnetic noise by making-analyzing-testing it's sample.

  • PDF

The Diagnosis of Cooling Tower System (Cooling Tower System 진동 진단)

  • Lee, Sun-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1090-1094
    • /
    • 2007
  • The aim of this study is to estimate the cause of Cooling Tower vibration and eliminate the faults of fan with high vibration in spite of overhaul. The cause of high vibration was that the natural frequency of fan blade coincide with second blade pass frequency. To achieve reduction of Cooling Tower vibration, change motor speed from 1784rpm to 1714rpm, and then the vibration has reduced conspicuously.

  • PDF

Characteristin Analysis of UPS Fan Noise Reduction by Multiple-Referedce/Multiple-Output FXLMS Algorithm (다중-레퍼런스/다중-출력 FXLMS 알고리즘에 의한 UPS 팬 소음저감 특성해석)

  • 이승요;조준석;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.589-600
    • /
    • 1999
  • Audible noise of UPS(uninterruptible power supply) with small rated [Xlwer is usually generattxl by the c cooling fan‘ For active noise control for radiated noise of UPS, it is adequate to apply multiple-channel F FXLMS algorithm based on Filten어 x LM~longrightarrow algorithm. In this paper, to reduce the audible noise of UPS‘ Its m noise characteristics of UPS are an띠yzed and active noise control by using 이ffiMOClVlultiple- Reference/ M Multiple-Output) FXLMS algorithm is perf‘onned. Also, noise reduction characteristics are shown by computer S simulation and experimental results.

  • PDF

Noise Prediction of Ducted Fan Unmanned Aerial Vehicles considering Strut Effect in Hover

  • Park, Minjun;Jang, Jisung;Lee, Duckjoo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.144-153
    • /
    • 2017
  • In recent years, unmanned aerial vehicles (UAVs) have been developed and studied for various applications, including drone deliveries, broadcasting, scouting, crop dusting, and firefighting. To enable the wide use of UAVs, their exact aeroacoustic characteristics must be assessed. In this study, a noise prediction method for a ducted fan UAV with complicated geometry was developed. In general, calculation efficiency is increased by simulating a ducted fan UAV without the struts that fix the fuselage to the ducts. However, numerical predictions of noise and aerodynamics differ according to whether struts are present. In terms of aerodynamic performance, the total thrust with and without struts is similar owing to the tendency of the thrust of a blade to offset the drag of the struts. However, in aeroacoustic simulations, the strut effect should be considered in order to predict the UAV's noise because noise from the blades can be changed by the strut effect. Modelling of the strut effect revealed that the dominant tonal noises were closely correlated with the blade passage frequency of the experimental results. Based on the successful detection of noise sources from a ducted fan UAV system, using the proposed noise contribution contour, methods for noise reduction can be suggested by comparing numerical results with measured noise profiles.