Numerical Analysis of Flow-Induced Noise and Fan Performance in Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음 및 팬 성능 해석)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2632-2637
    • /
    • 2007
  • Rotary performance and flow resistance induced by each element in suction nozzle of a vacuum cleaner with a double-blade rotary fan are investigated numerically and its relation with flow-induced noise and rotary performance is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. Gap between double blades, adoption of cross-flow fan, enlargement of flow inlet area, and optimization of blade number are tested for noise reduction. Finally, the effects of each method are verified experimentally. It is found that several combinations of the proposed methods can be adopted for noise reduction although the degree of reduction is not much.

  • PDF

Noise Reduction of a Ventilating Fan System using Micro-Perforated Panel (미세 다공판을 이용한 환기팬 시스템의 소음저감)

  • Lee, Jong-Seuk;Song, Hwa-Young;Lee, Dong-Hoon;Kwon, Hyuk-Jung;Kim, Dong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1209-1211
    • /
    • 2006
  • This paper introduces an experimental study for the noise reduction of a ventilating fan system. For the purpose of noise reduction, conventionally an absorptive duct silencer filled with a glass fiber has been utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with its noise reduction performance.

  • PDF

A Research on the Noise Reduction of Range Hood for Household (가정용 레인지 후드의 소음저감에 관한 연구)

  • Hong, Byung-Kuk;Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.449-452
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which squawky noises are generated. Though the squawky noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level omitted front the range hood is decreased above 2dB(A) in all frequency regions due to the effect of noise reduction by perforated panel system.

  • PDF

Study on the Noise Reduction of BLDC Fan Motor by Cogging Torque Reduction (코깅토크 저감에 의한 BLDC Fan & Motor의 공진 소음 개선에 관한 연구)

  • Shin, Hyoun-Jeong;Lee, En-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1217-1222
    • /
    • 2013
  • It is very important to diminish noise source of electric motor systems that are used for home appliance area. We have studied on the noise reduction of BLDC motor, mainly focusing on reducing noise source from cogging torque. This noise source causes resonance of fan & motor systems. This study showed that the higher harmonic component of the cogging torque was the main factor for noise generation. Therefor, to reduce noise of bldc motor for refrigerator, this study suggested peanut shaped magnet which surface flux has similar sinusoidal wave form.

A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner (청소기의 공력소음 특성 파악 및 저소음화에 관한 연구)

  • 전완호;백승조;김창준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.460-466
    • /
    • 2003
  • The aeroacoustic characteristics and noise reduction method of a centrifugal fan for a bagless vacuum cleaner were studied. The major noise source of vacuum cleaner is the centrifugal fan. The impeller of the fan rotates over 30000 rpm and generates very high-level piercing noise. It was found that the dominant noise source of the fan is generated from the aerodynamic interaction between the highly rotating impeller and stationary diffuser. In order to reduce the high tonal sound generated from the aerodynamic interaction between the impeller and diffuser, tapered impeller was carefully designed and tested. The trailing edge of the tapered impeller was inclined and this reduces the flow interactions between the rotating impeller and the stationary diffuser because of some phase shift. The static efficiency of the new impeller is slightly lower than the conventional one. The overall SPL is reduced about 3.6 dBA. The SPL of blade passing frequency(BPF) is reduced about 6 dBA and the $2^{nd}$ BPF is reduced about 20 dBA. The vacuum cleaner with the tapered impeller has lower noise level than that of the previous impeller and the strong tonal sound was dramatically reduced.

A Research on the Noise Reduction of a Kitchen Ventilation System and the Prediction of Sound Distribution in a Kitchen and Room (주방환기 시스템의 소음 저감과 실내 음장분포 예측에 관한 연구)

  • Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun;Hong, Byung-Kuk
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.494-499
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which harsh noises are generated. Though the harsh noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood was decreased more than 10dB(A) in all 1/3 octave bands due to the effect of noise reduction by perforated plate systems.

  • PDF

A Study on the Noise Reduction of Axial Flow Fan (축류형 팬의 저소음화에 관한 연구)

  • Oh, J.E.;Yi, S.J.;Lee, S.H.;Lee, D.I.;Kim, C.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.142-149
    • /
    • 1995
  • Axial fans are very useful cooling devices being widely used in many electric and industrial machinery. However those are often accompanying annoying noise. Many efforts have been devoted in order to reduce the fan noise. In this study, the procedure was devided into two major parts in considering effects of design parameters of axial fan concerned with noise ; the fan theory and the Fukano's fan noise study. By using the fan theory we defined stagger angle, camber angle, blade inlet and outlet angle for studying low noise fan. Then the effects of such angles on the flow rate and static pressure were investigated. By using the Fukano's fan noise theory, the relations of the chord length, the rotational speed and the number of blades vs. fan noise are investigated.

  • PDF

Study on Noise Reduction of An Axial Flow Fan According to the System Characteristics (시스템 특성을 고려한 축류팬 저소음화에 대한 연구)

  • Yoon, Hong-Yeol;Kim, Chang-Jun;Song, Sung-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1381-1385
    • /
    • 2000
  • In this paper, a guideline of axial flow fan design for noise reduction of refrigerators is p resented. Refrigerators have components which have a role to screen particular frequency air borne-noise which is generated by an axial flow fan set in them. Effective ways to use the particular characteristic of refrigerators are shown in this study. As a result of application of the methods, we reduced the noise of the target systems by more than 3 dB(A) from the viewpoint of air-borne noise produced by the axial flow fan set.

  • PDF

Design of automotive engine cooling fan and study on noise reduction through modification of system (자동차용 냉각팬의 설계와 시스템 개선을 통한 저소음화 연구)

  • 김병주;강상규;김규영;이덕주;이재영;이덕호;신동수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.196-201
    • /
    • 2003
  • Axial fans are widely used for automotive engine cooling device due to their ability to produce high flow rate to keep engine cool. At the same time, the noise generated by these fans causes one of the most serious problems. Especially, engine cooling fan noise in idle condition of a car is noticeable. Therefore, the high efficient and low-noise fan is seriously needed. When a new fan system is designed, system resistance and non-uniform inflow are the key factors to get the high performance and low noise fan system. In this study, experimental study on the fan and system was carried out and brought a successful result of performance and noise from a designed fan. And through the modification of the fan system, the fan produced more flow rate and became less noisy.

  • PDF

Development and Analysis on Noise Characteristics of Low Noise Cooling Fan for an Alternator by Using Numerical Method (수치적 방법을 이용한 저소음 얼터네이터 냉각팬의 개발 및 소음 특성 분석)

  • Kim, Wook;Jeon, Wan-Ho;Hyun, Jae-Jin;Lim, Chul-Koo;Lee, Sung-Ha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.608-609
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and FlowNoise S/W are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF