• Title/Summary/Keyword: Fan Identification

Search Result 66, Processing Time 0.022 seconds

Estimation of Vibration Source and Sound Radiation of a Refrigerator Fan by using Measured Acceleration Signals (가속도 측정신호를 이용한 냉장고 홴의 진동원과 방사소음의 예측)

  • Jung, Byung-Kyoo;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.834-841
    • /
    • 2011
  • Obtaining the real exciting force is important for the analysis of structural vibration or sound radiation to represent the actual condition. But in most cases, it is so difficult to get the actual force signals by direct measurement using sensors due to complex geometry. This paper suggests advanced source identification method which can be applied to the prediction of radiated noise considering correlations between measured signals. This method was implemented to the identification of the fan force in the refrigerator. The analysis of structural vibration and radiated noise caused by the fan force was also performed. The comparison between predicted SPL and measured SPL of the radiated noise by the refrigerator fan showed good agreement.

The Influence of Professional Baseball Fan's Team Identification and Team Loyalty on Purchase Intention of Parent Company Products (프로야구 팬의 팀동일시와 팀충성도가 모기업 제품 구매의도에 미치는 영향)

  • Song, Hong-Rak;Ryu, Won-Yong
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.445-452
    • /
    • 2016
  • The purpose of this study was empirically to reveal how professional baseball fan's team identification and team loyalty influence on purchase intention of parent company products. For the research, a survey was conducted by 278 subjects selected from fans of Samsung Lions and LG Twins among professional baseball teams which were owned by representative electronics manufacturers. The results were as follows: First, team identification of the professional baseball fan had positive corelation with purchase intention of parent products. Second, team loyalty of the professional baseball fan had positive corelation with purchase intention of parent company products. Third, team loyalty had effective to mediate between team identification and purchase intention of parent company products. The result of studies showed that team identification was a major factor(variable) which had a positive influence on purchase intention of parent company products, and it also verified that team loyalty had mediating effects on these.

The Development Process Model of Sports Fan Loyalty via CSR of Professional Sports Teams

  • CHA, Jaehyuk;LEE, Hwan-Yeol;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.4 no.2
    • /
    • pp.45-51
    • /
    • 2020
  • Purpose: The purpose of this study is to investigate how sports fans' loyalty is built via CSR activities of professional sports teams. Furthermore, the study sought to suggest the model presenting the process of developing loyalty of sport fans by teams' CSR performance. Research design, data, and methodology: For this purpose, a survey was conducted on 450 professional sports fans through the convenience sampling method. A total of 357 of the data were used for the final analysis. Based on the collected data, frequency analysis, reliability analysis, confirmatory factor analysis, and structural equation model analysis were conducted. Results: The results showed that CSR activities contribute to building a positive image of team. Regarding fan identification, team image has also a positive effect on enhancing identification. The finding has supported the notion that attitudinal loyalty is enhanced by fan identification and further attitudinal loyalty significantly influences behavioural loyalty of fans. Conclusions: The results of this study explored the function of CSR of the teams on attitudinal and behavioural outcomes, loyalty. Moreover, the study suggested the constructual model presenting its role on enhancing fans' attitudes and behaviour affecting participation and consumption. Academic and practical implications were discussed for sport marketers and practitioners.

Fault Detection using Parameter Identification for Fan system (Fan System의 Parameter ID를 통한 고장 검출)

  • Park, Dae-Sop;Shin, Doo-Jin;Huh, Uk-Youl;Lim, Il-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.549-551
    • /
    • 1999
  • Recently, Several type of motors are used more widely in Fan system because of their low cost and high reliability. Therefore, the importance of fault detection and isolation of fan system significantly increases. The motor is a important factor bring out the fan system fault. So the problem of a fault detection for motor based on a parameter identification will be considered in this paper. After an introduction into fault detection with parameter estimation, a mathematical model for motor with special emphasis on motor itself. In the fault detection system, current and motor speed are used as parameter. Finally, simulation results are used to demonstrate the efficiency of the fault detection system.

  • PDF

A study on the aeroacoustic characteristics of the sirocco fan of over the range (후드겸용 전자렌지 시로코홴의 소음특성에 관한 연구)

  • Jeon, Wan-Ho;Song, Sung-Bae;Sohn, Sang-Bum;Rew, Ho Seon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.123-128
    • /
    • 2002
  • Over the range(OTR) has been applied for cooking and ventilation functions especially in northern Amarica. Because flow rate and operating rpm of the double sided sirocco fan for ventilation are much higher and than the microwave oven system, the major noise source is the sirocco fm. Recently, the quiet fan development is one of very important issues for amenity. In this study, the noise source identification using multi-microphone array system was carefully carried out and numerical simulations for understanding the aerodynamic and aeroacoustic of the fan were peformed. The sound level of tonal noise is predicted with a good accuracy but that of the broadband shows some discrepancy. In order to reduce the broadband noise, the inlet region of sirocco fan have to be modified that the secondary flow should be suppressed. Based on these results, new low noise fan and OTR is now developing.

  • PDF

A Study on the Determinants of Fans' Team Identification in KBO League : Focused on the Effects of Kids Marketing (프로야구 팬의 팀 동일시에 영향을 미치는 요인에 관한 연구: 응원시작 연령의 효과를 중심으로)

  • Choi, Seung-Nyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.99-110
    • /
    • 2016
  • This study examined the factors affecting the team identification of professional baseball fans. The factors were divided into the fan factor, game factors, and other factors. For the analysis, two investigators visited stadium three times in total and a total number of 297 spectators were sampled using a convenience sampling method from three baseball teams. For the fan factor, a fan who began supporting his/her team from childhood or after childhood was used as a dummy variable. The interaction effects between the fan factor and other variables were investigated to offer a stereoscopic understanding about the role of kids marketing. In addition, three game factors and four non-game factors were analyzed. The results regarding fan variable and interaction effects were obtained. Fans from their childhood have much stronger team identification, and show interaction effects with the players. Regression analysis revealed player, promotion and fan service, price, and regional connection to have positive relations with team identification. This study is especially meaningful in a sense that it has proposed positive results regarding marketing to children, and the results will contribute to both the academic field and the industry.

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (에어컨 실외기의 소음원 규명 및 소음저감)

  • 서상호;임금식;이내영;진심원
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1043-1052
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan. heat exchanger and shroud. First. the fluid noise is reduced through the design of new fan and shroud. reduction of the system resistance by rearrangement of heat exchanger. and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4∼5dB (A).

  • PDF

Acoustic Noise Source Identification and Analysis of Dynamic Characteristics Parameters In BLDC Fan Motor (BLDC Fan Motor의 소음원 규명 및 동특성 분석)

  • Shin, Hyoun-Jeong;Lee, En-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1397-1402
    • /
    • 2013
  • This study researched cause of resonance noise for BLDC motor used in the refrigerator. it is difficult to measure dynamic characteristics for small sized fan & rotor system with conventional excitation method. Therefore this study performed electric exiting method and natural frequency method using microphone instead of conventional excitation and showed validity of these methods. Study result showed that tortional vibration frequency of fan & rotor system and natural bending frequency of the fan were matched with exciting frequency of BLDC motor caused by commutating ripple torque. And this frequency match caused resonance of the system. The study analyzed main parameters of this phenomenon and suggested alternative solution.

Transient Vibration Identification and Reduction of a Centrifugal Fan for a Wall-installed Air-conditioner (벽걸이에어컨의 원심홴에 대한 과도진동 규명 및 저감)

  • Kim, Minsung;Lim, Jonghyuk;Chung, Jintai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.383-390
    • /
    • 2016
  • In this paper, experiment and dynamics simulations were carried out to identify and reduce the out-of-plane vibration that occurs in a centrifugal fan of an air conditioner installed to a wall. In a wall-installed air conditioner, large space between a case and heat exchanger is often required for the fan to avoid the collision with the case and exchanger. This large space hinders the slim design of the air conditioner even if air conditioner market demands a slim air conditioner. In the present study, in order to determine the cause of the vibration in the centrifugal fan, the out-of-plane vibration and the physical properties were investigated, and the dynamic characteristics of the centrifugal fan were obtained by experiments. Based on these experiments, a dynamic simulation model was established to determine the cause of the out-of-plane vibration of the centrifugal fan. It was found that the main factor of out-of-plane vibration in the centrifugal fan is the axial misalignment between the centrifugal fan and the motor shaft.

Acoustic Noise Source Identification and Analysis of Dynamic Characteristics Parameters in BLDC Fan Motor (BLDC Fan Motor의 소음 원 규명 및 동 특성 분석)

  • Shin, Hyun-Jeong;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.861-864
    • /
    • 2006
  • 냉장고에 적용된 BLDC Fan Motor에 있어서 공진소음의 원인에 대하여 연구하였다. 연구에 있어서 종래의 가진 방법을 적용하기 곤란한 구조를 가진 소형 Fan & Rotor System의 동 특성 실험에서 전자 가진법 및 Microphone을 이용한 고유진동수 계측방법을 사용하고 그 타당성을 보였으며 연구결과, Pan과 Rotor System의 비틀림 고유진동수와 Fan의 굽힘 고유진동수가 BLDC Motor의 Commutating Torque Ripple에 의한 가진 주파수와 일치하여 공진이 발생하는 것으로 분석 되었으며 이와 관련된 주요 인자를 분석하고 대안을 제시하였다.

  • PDF