• 제목/요약/키워드: Fan Design

검색결과 894건 처리시간 0.026초

슬림형 룸에어컨 설계 인자에 관한 연구 (Numerical and Experimental Analysis of Design Parameters of a Slim Room Air-conditioner)

  • 신종진;이희술;김종문;민준기;오상경
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.95-100
    • /
    • 2005
  • Numerical simulations and experiments were conducted to analyze the design parameters for a slim room air-conditioner. These design parameters included a fan shape, a front panel, a scroll shape, a bell mouth, a distance between a fan and a heat exchanger, etc. Each design parameter was analyzed numerically and/or experimentally in terms of the flow rate and the sound pressure level, which should be the most influential factors for developing the slim room air-conditioner. The fan with a uniform height showed a better performance than that with a linearly varying height. It is recommended to use a front grill rather than a front panel according to sound pressure levels since the front panel itself is a huge resistance to the inlet flow. A redesigned scroll shape by changing the rotational direction of a fan also contributed a lot to lowering the sound pressure level. There existed a distance between a fan and a heat exchanger, where flow rates increased effectively.

홴 후방 유동장을 고려한 홴싱크 설계에 관한 연구 (A Study on the Design of a Fan-Sink Considering the Flow Fields Behind the Fan Outlet)

  • 조진수;한승호;한철희
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1055-1061
    • /
    • 2002
  • A numerical and experimental study on the flow fields behind the fan outlet was carried out to improve the performance of a conventional fan-sink(fan and heat sink). Conventional fan-sinks have a heat sink of which fin configurations tend to increase the flow resistance, thus decreasing the performance and the cooling capabilities of a fan-sink. Lifting surface method is used for the prediction of flow fields behind the fan outlet. Oil-dot flow visualization technique is applied for the validation of numerical results. The numerical results and experimental data show agreement each other. A conventional heat sink is modified and redesigned using flow patterns behind the fan outlet. The newly designed heat sink has the configuration of curved fins which minimize flow resistance. It showed improvements in both cooling: capabilities and volumetric flow rate compared to the conventional one.

와류 저감을 통한 냉장고 냉기순환용 고성능/저소음 원심홴의 개발 (Development of High-performance/low-noise Centrifugal Fan Circulating Cold Air Inside a Household Refrigerator by Reduction of Vortex Flow)

  • 신동휘;유서윤;정철웅;김태훈;정지원
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.428-435
    • /
    • 2016
  • In this paper, high-performance and low-noise centrifugal fan used to circulate cold air inside a household refrigerator is developed by reducing the vortex flow observed near the tip of fan hub. First, the performance of the existing centrifugal fan is investigated through the experiment using a fan tester and the characteristics of detailed flow field obtained from the CFD simulation are closely examined. The strong vortex flow is observed in the vicinity of the tip of fan hub. Based on this result, new design is devised to reduce this vortex flow. As a result, it is numerically and experimentaly found that the volume flow rate of the new fan increases and the radiated noise decreases in comparison with the existing fan at the same rotation speed.

석유 홴 히터의 난방 능력 고찰 (Investigation of Heating Performance of Kerosene Fan Heater)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

저소음 축류형 소형홴의 개발 (Design of Low Noise Axial-Tube Fan)

  • 김기황;이승배;김병홍
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.17-22
    • /
    • 2001
  • Tube axial fans were designed to provide effective cooling for a personal computer by using $DasignFan^{TM}$ software. With basic input parameters of flow rate, pressure rise, rotating speed, and fan diameter, three dimensional geometry of blade is automatically generated and its performance and overall sound pressure level are predicted. In this steady, the newly developed fans of 60 mm and 80 mm diameters were proved to provide a very promising mode of low noise, compared with manufactured products.

  • PDF

석유 팬 히터 디자인 개발 사례 연구 - '92금성사 석유팬 히터를 중심으로 - (A CASE STUDY ON DEVELOPING A DESIGN OF OIL FAN HEATER - With a focus on '92 GoldStar Co Oil fan heater -)

  • 오성진
    • 디자인학연구
    • /
    • 제6권1호
    • /
    • pp.47-72
    • /
    • 1993
  • Nowadays conmpetltlOn of developing new products is getting keen. We can notice that the role and importance of design are emphasized more than ever.The main cause of this tendency is that technical power is no more a factor which secures the superiority in products competition, as technology is gneneralized in the world. Therefore, design is recognized intensely as a competitive strategy to promote competitive power of products. It is an already known fact that the design for both rational function and charming form to satisfy consumer's desires is a short cut to success, when a company develops a new product to promote competitive power in market. The design which plays a leading role in the activity of developing more cnovenient, more economical and more aesthetic products is called 'Competitive Edge' or 'New Corporate Weapon'. Judging form each company's case of developing products, we can guess that it has its own plan and process of developing new products with defferdnl interest and effort. The strategy of developing products is considered as the most important factor that affects the very existence of rhe company. This thesis is composed of six chapters in all. In the firstchapter, I describe the purpose, method, and scope of study.The second chapter includes the image of form in oil fan heater market in nearby Japan and that of interior in our domestic home and shops, and the trend of word life cycle by analyzing circumstances. The third chapter focuses on consumer's attitude. In the fourth chapter, I compare and test current products of competitive companies including Samsung, Daewoo, Shinilwith those of Gold STar. The trend of products, technique, and design which resulted form this comparison is described. In the fifth chapter I explain the strategy, and process of design of oil fan heater in 1992. The last conclusive chapter presents the major point drawed form the case study, but not includes an estimation of products and the condition of market. In this thesis, I reconsider the general understanding of design and designing process and the value of design as a main factor in the strategy of management by investigating the development of products and the strategy of design, and the process of design.

  • PDF

유량에 따른 축류홴의 익단누설와류 및 후류 특성 (Flow Characteristics of Wake Flow with Relation to a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 김광용;장춘만
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.322-329
    • /
    • 2005
  • The flow characteristics in the blade passage and in the wake region of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From axial velocity distributions downstream of the fan rotor, large axial velocity decay near the rotor tip is observed at near stall condition, which results in large blockage compared to that at the design condition. Although the wake flow downstream of the rotor blade is clearly measured at all operating conditions, the trough of the high velocity fluctuation due to Karmann vortex street in the wake flow is mainly observed at a higher flow condition than the design flow rate.

허브 형상에 따른 정풍량 환기팬의 유동과 성능특성 (Flow Behavior and Performance Characteristics of Constant Air Volume Fan According to Different Hub Shape)

  • 이호호;최항철;정재구;이윤표;신유환;정진택
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.57-62
    • /
    • 2012
  • The constant air volume flow fan can maintain constant flow rate to the wide range of exit pressure. Therefore, the use of this fan is increasing recently for ventilation of high building. Brushless DC motor is adopted to this fan because that has advantages of compactness and performance. But this type of motor protrude from impeller hub side to fan inlet. The Impeller inlet flow is influenced by size of this obstacle called hub. In this paper, the influence of hub shape on the fan performance characteristics are experimentally and numerically analyzed. CFX 12.0 is used to perform the fan internal flow analysis and numerical results are compared with the experiments. Depending on hub shape, internal loss is generated and the performance and efficiency are reduced. The best performance is occurred around $h/b_1$ = 0.25. The results of this study will be contribute to initial design of constant air volume flow fan development.

축류송풍기의 스윕각이 소음에 미치는 영향에 대한 연구 (A Study on the Effect of Sweep Angle of Axial Fan on Its Noise)

  • 최재호;김광용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.365-370
    • /
    • 2000
  • A computational study on the effect of sweep angle of axial fan on its noise is performed in the present paper. The forward swept axial fan was designed by numerical optimization method incorporated with three dimensional flow analysis. The objective function was defined by the ratio of generation rate of turbulent kinetic energy to pressure head. And, two variables related with sweep angle distribution are used for design variables. The swept fan has better performance characteristics and noise level. The experimental result shows that spectrums of no-sweet and swept fans have differences in the blade passage frequency, especially in the broadband. And the overall noise level of swept fan is lower 10dB(A) than that of no-sweep fan. For the comparison of flow fields between no-sweep fan and swept fan, CFX-TASCflow computational fluid dynamics software is used. Standard k-${\varepsilon}$ model is used for the turbulence model. Distributions of pressure and turbulent kinetic energy distributions are compared in order to find what happen in the low-noise swept fan.

  • PDF

테일홴 성능시험장치의 운용과 진동특성 (The Operation and Vibration Characteristics of Tail-fan Performance Test System)

  • 송근웅;김준호;강희정;이욱;심정욱
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.421-428
    • /
    • 2005
  • This paper described operation and vibration characteristics of a 'tail-fan' anti-torque performance test system. KARI (Korea Aerospace Research Institute) developed a 'tail-fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the tail-fan. The performance test-rig consists of driving, supporting and rotating parts. In the process of the performance test, firstly, operation test of the test-rig were carried out to verify design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for the performance test, vibration test were carried out using accelerometers on tail gear box. The performance test conditions of the tail-fan to avoid a resonance were found from the fan-plot and vibration test results. The tail-fan performance tests were well done safely.