• 제목/요약/키워드: Fan Blade

검색결과 358건 처리시간 0.027초

대규모 와 모사에 의한 3차원 소형축류홴의 운전부하에 따른 난류유동 특성치 고찰 (An Investigation on Turbulent Flow Characteristics According to the Operating Loads of Three-Dimensional Small-Size Axial Fan by Large Eddy Simulation)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.50-56
    • /
    • 2016
  • This paper handled an investigation on the turbulent flow characteristics of three-dimensional small-size axial fan(SSAF) according to operating loads. Also, it was carried out by unsteady-state, incompressible and three-dimensional large eddy simulation(LES). The downstream flow type of SSAF is changed from axial flow to radial flow around the beginning of stall region at the aerodynamic performance curve. Axial mean velocity component largely grows around blade tip at the operating point of A to D, but transverse and vertical mean velocity components as well as Reynolds shear stresses highly develop around blade tip at the operating point of E to H. On the other hand, the peak value of turbulent kinetic energy developed around blade tip shows the highest at the operating point of E.

반도체 설비의 Fan Filter Unit 에서 발생하는 진동이 Wafer 생산성에 미치는 영향

  • 조귀영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.121-121
    • /
    • 2014
  • 본 연구에서는 반도체 제조의 Diffusion 공정설비의 FFU (Fan Filter Unit) 진동에 의해 발생한 wafer 불량 현상을 규명 및 개선하였다. EFEM(Equipment Front End Module)의 Loading 부에 장착된 FOUP(Front Opening Unified Pod)에 들어 있는 Wafer 들이 설비 EFEM 하부로 떨어져 깨지거나 FOUP 내에서 겹침 현상이 발생하는 것을 확인하였다. 이에 생산현장의 모든 Diffusion 공정 설비를 조사하였으며, 그 결과 A 사(社)의 특정 설비에서만 발생되는 현상임을 확인하였다. 해당 A사(社)설비군에서만 월 평균 10 건의 Slot Mapping Error 가 발생하였으며, 이로 인해 Wafer가 재 제조된 매수가 월 평균 53 매로 확인되었다. 따라서 본 연구는 A 사(社)설비에서 발생하는 Mapping Error 의 원인 규명 및 개선을 위해 추진되었다. 총 12 개의 항목을 불량 발생 원인 후보 군으로 선정 후 예비 진단한 결과 FFU(Fan Filter Unit)에 의한 문제 발생 가능성이 가장 높을 것으로 추정되었다. 이에 따라 4 개의 서로 다른 물리적 환경/조건에서 진동을 측정하였으며, 최종 평가 결과 Motor 와 Blade 의 불균형에서 기인한 진동이 설비의 loader 부에 직접적으로 영향을 주는 것을 확인하였다. 진동 문제를 해결하기 위해 고 RPM blade 에서 저 RPM 및 유량 감소를 보완할 수 있는 신규모델로 교체하였다. 신규 Module(blade/motor) 장착 후 Load port 에서의 진동 측정 결과 개선 전 대비 91% 감소하였으며, 결과적으로 Slot mapping error 발생 건수가 50% 이상 감소되는 효과와 Wafer 재 제조 매수도 월 평균 약 43% 감소하는 효과를 얻을 수 있었다.

  • PDF

신경망 최적화 기법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화 (Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Neural Network)

  • 한석영;맹주성;유달현;진경욱
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1341-1347
    • /
    • 2002
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and neural network. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. The distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure have qualitative similarity. The results of two-dimensional CFD were used for teaming as target values of neural network. The optimal angle and radius of cut-off were determined as 71$^{\circ}$and 0.092 times the outer diameter of impeller, respectively. It is quantified in the previous report that the optimal angle and radius of cut-off are approximately 72$^{\circ}$and 0.08 times the outer diameter of impeller, respectively.

반응표면법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화 (Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Response Surface Method)

  • 한석영;맹주성;황영민
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.225-231
    • /
    • 2003
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and response surface method. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. In order to examine the validity of the two-dimensional CFD the distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure show qualitatively similarity. The results of two-dimensional CFD were used for constructing the objective function with design variables using response surface method. The optimal angle and radius of cut-off were determined as $72.4^{\circ}$ and 0.092 times the outer diameter of impeller, respectively. It is quantified the previous report that the optimal angle and radius of cut-off are approximately $72^{\circ}$ and 0.08 times the outer diameter of impeller, respectively.

Vortices within a Three-Dimensional Separation in an Axial Flow Stator of a Diagonal Flow Fan

  • Kinoue, Yoichi;Shiomi, Norimasa;Setoguchi, Toshiaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권2호
    • /
    • pp.262-270
    • /
    • 2011
  • Experimental and numerical investigations were conducted for an internal flow in an axial flow stator of a diagonal flow fan. A corner separation near the hub surface and the suction surface of a stator blade was focused on, and further, three-dimensional vortices in separated flow were investigated by the numerical analysis. At low flow rate of 80% of the design flow rate, a corner separation of the stator between the suction surface and the hub surface can be found in both experimental and calculated results. Separation vortices are observed in the limiting streamline patterns both on the blade suction and on the hub surfaces at 80% of the design flow rate in the calculated results. It also can be observed in the streamline pattern that both vortices from the blade suction surface and from the hub surface keep vortex structures up to far locations from these wall surfaces. An attempt to explain the vortices within a three-dimensional separation is introduced by using vortex filaments.

A Suggested Mechanism of Significant Stall Suppression Effects by Air Separator Devices in Axial Flow Fans

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.57-66
    • /
    • 2011
  • Radial-vaned air separators show a strong stall suppression effect in an axial flow fans. From a survey of existing literature on the effects and the author's data, a possible mechanism for the significant effects has been proposed here. The stall suppression is suggested to have been achieved by a combination of the following several effects; (1) suction of blade and casing boundary layers and elimination of embryos of stall, (2) separation and straightening of reversed swirling flow from the main flow, (3) induction of the fan main flow toward the casing wall and enhancement of the outward inclination of meridional streamlines across the rotor blade row, thus keeping the Euler head increase in the decrease in fan flow rate, and (4) reinforcement of axi-symmetric structure of the main flow. These phenomena have been induced and enhanced by a stable vortex-ring encasing the blade tips and the air separator. These integrated effects appear to have caused the great stall suppression effect that would have been impossible by other types of stall prevention devices. Thus the author would like to name the device "tip-vortex-ring assisted stall suppression device".

Application of Gurney Flaps on a Centrifugal Fan Impeller

  • Dundi, Thomas Manoj Kumar;Sitaram, Nekkanti;Suresh, Munivenkatareddy
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권2호
    • /
    • pp.65-71
    • /
    • 2012
  • The objective of the present investigation is to explore the possibility of improving the performance of a centrifugal fan at low Reynolds numbers using a simple passive means, namely Gurney flap (GF). GFs of 1/$8^{th}$ inch brass angle (3.175 mm) corresponding to 15.9% of blade exit height or 5.1% of blade spacing at the impeller tip are attached to the impeller blade tip on the pressure surface. Performance tests are carried out on the centrifugal fan with vaneless diffuser at five Reynolds numbers (viz., 0.30, 0.41, 0.55, 0.69, $0.82{\times}10^5$, i.e., at five speeds respectively at 1,100, 1,500, 2,000, 2,500 and 3,000 rpm) without and with GF. Static pressures on the vaneless diffuser hub and shroud are also measured for each speed at four flow coefficients [${\phi}$=0.23 (below design flow coefficient), ${\phi}$=0.34 (design flow coefficient), ${\phi}$=0.45 (above design flow coefficient) and ${\phi}$=0.60 (above design flow coefficient)] with and without GF. From the performance curves it is found that the performance of the fan improves considerably with GFs at lower Reynolds numbers and improves marginally at higher Reynolds number. Similar improvements are observed for the static pressures on the diffuser hub and shroud. The effect of Reynolds number on the performance and static pressures is considerable. However the effect is reduced with GFs.

냉각탑용 축류형 F.R.P. 팬의 개발 (Development of an Axial F.R.P. Fan for Cooling Tower)

  • 오건제;김선숙
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.735-741
    • /
    • 2007
  • An axial F.R.P. fan model for cooling tower is developed. The fan is designed using the equations for one dimensional inviscid flow through the fan blade. Fan shape is swept forward with a parabolic function. Calculations of the three dimensional turbulent flow around the fan are carried out to investigate performance of the fan. Data of the total pressure rise and hydraulic efficiency can be obtained for the various setting angles. Calculated values of the total pressure rise and hydraulic efficiency at the design point are less than those of the design specification. The prototype of the F.R.P. fan is made by laminating of the fiberglass and epoxy resins on the mold of fan shape.

축류형 송풍기 저소음 설계 프로그램의 개발 및 평가 (Evaluation of Design Program of Low-Noise Axial Fan)

  • 김기황;박준철;김진화;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.967-972
    • /
    • 2001
  • An axial fan design code, called iDesignFan$^{TM}$, was developed. In this code, three major loss models were used to predicted the aerodynamic performance of a fan. The overall sound pressure level, predicted from steady blade loading, is also used as an input parameter from the third loop of the designing process to acquire most silent fan for the given aerodynamic performance parameters. With this kind of inverse design concept used in this code, the period of designing a fan, which has given aerodynamic performance with minimal acoustic noise, is significantly shortened. The experimental results of a prototype fan, designed by this code, showed that aerodynamic and acoustic performance of an axial fan is reasonably well predicted. Thus, one can design/develop an axial fan in a short time by using the code.e.

  • PDF

반응표면법을 이용한 원심팬 성능/소음 최적화 (Performance/Noise Optimization of Centrifugal Fan Using Response Surface Method)

  • 신동휘;허승;정철웅;김태훈;정지원
    • 대한기계학회논문집A
    • /
    • 제41권3호
    • /
    • pp.165-172
    • /
    • 2017
  • 본 논문에서는 가정용 냉장고의 내부 냉기순환용 원심팬의 고성능/저소음 최적설계를 수행하였다. 최적설계를 위해 여러 독립변수들이 어떠한 종속변수에 영향을 줄 때 용이하게 적용할 수 있는 반응표면법을 사용하였으며, 블레이드의 입구각, 출구각, 내경을 독립변수로 선정하였다. 먼저 이를 통해 팬 블레이드의 유량을 최대화하였으며, 3-D 프린터를 이용해 샘플을 제작하였고, 만들어진 팬의 P-Q곡선을 측정하여 개선된 팬이 유량의 증가를 보임을 확인하였다. 또한 기존 팬과 동일한 유량을 가지도록 새로운 팬의 회전속도를 저감시킬 경우, 1.7 dBA의 소음 저감 효과가 있음을 확인할 수 있었다.