• Title/Summary/Keyword: False Report

Search Result 169, Processing Time 0.029 seconds

Bechet`s Disease with Multiple Aterial Abeurysm; A Case Report (Bechet`s disease에 동반된 다발성 동맥류;1례 보고)

  • 조재호
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.316-319
    • /
    • 1993
  • Although Behcet`s disease, characterized by oro-genital ulceration and ocular abnormalities, is rare and unfamiliar disease to thoracic surgeon, one must remember that it can cause serious complications on the vascular system such as thrombophlebitis,thrombotic obstuction and aneurysm.We report a case of multiple arterial aneurysms with Behcet`s disease. This 31 year-old female had five times surgical interventions during short period[19 months]. 6 aneurysms were developed in this case, 3 were spontaneous aneurysms, 2 were anastomotic aneurysms and 1 was false aneurysm due to arterial puncture.

  • PDF

One case report of mid-thoracic esophageal diverticulum (식도중간부 식도게실: 1 수술 치험례)

  • Sun, Kyung;Choi, Young-Ho;Chae, Sung-Soo;Kim, Hark-Jei;Kim, Hyong-Mook
    • Journal of Chest Surgery
    • /
    • v.15 no.4
    • /
    • pp.447-450
    • /
    • 1982
  • A 45 year old male officer was admitted due to upper substernal pain for 1 month, which was aggravated by swallowing. On past and family history, there was no specific history except heavy drinking. Simple chest x-ray revealed no specific abnormal findings. Preoperative esophagofiberscopy and Barium study showed midesophageal diverticulum, pulsion type, at about 2 cm below the left main bronchus. The opening of the diverticulum was located at the left posterolateral aspect of esophagus. Midesophageal false diverticulum, measuring 2 x 2 x 1 .S cm in size, was noted at about 5 cm under the aortic arch protruding through a slit-like muscular defect. After inversion of diverticular sac, interrupted sutures with 3-0 silks were done on muscular defect site, and mediastinal pleura was reinforced on the lesion with interrupted sutures. On 4th postoperative day, esophagography revealed no diverticulum or stenosis. Also esophagofiberscopy showed smooth mucosal tag without disturbance of passage. On 14th postoperative day, the patient was discharged uneventfully, and follow-up for 3 months after discharge revealed nothing abnormal symptoms. The authors report one case of midesophageal, pulsion type, false diverticulum.

  • PDF

Design of Sensor Network Security Model using Contract Net Protocol and DEVS Modeling (계약망 프로토콜과 DEVS 모델링을 통한 센서네트워크 보안 모델의 설계)

  • Hur, Suh Mahn;Seo, Hee Suk
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.4
    • /
    • pp.41-49
    • /
    • 2008
  • Sensor networks are often deployed in unattended environments, thus leaving these networks vulnerable to false data injection attacks in which an adversary injects forged reports into the network through compromised nodes. Such attacks by compromised sensors can cause not only false alarms but also the depletion of the finite amount of energy in a battery powered network. In order to reduce damage from these attacks, several security solutions have been proposed. Researchers have also proposed some techniques to increase the energy-efficiency of such security solutions. In this paper, we propose a CH(Cluster Header) selection algorithm to choose low power delivery method in sensor networks. The CNP(Contract Net Protocol), which is an approach to solve distribution problems, is applied to choose CHs for event sensing. As a result of employing CNP, the proposed method can prevent dropping of sensing reports with an insufficient number of message authentication codes during the forwarding process, and is efficient in terms of energy saving.

Chronic Dissecting Aortic Aneurysm with Right Coronary Artery Perfused Solely by False Lumen of Asceading Aorta (가성 내강에서 우측 관상동맥으로 혈류가 공급되는 원인 미상의 만성 박리성 대동맥류 1례 보고)

  • Go, Myeong-Gu;Kim, Jong-Myung;Lee, Kwan-Ho;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo;Hwang, Mee-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.159-166
    • /
    • 1988
  • Dissecting aortic aneurysm is relatively rare in those under 40 years of age without high risk factors. After dessecting aortic aneurysm is occured, the coronary artery is rarely perfused by false lumen. We present a thirty two-year-old man who showed Debakey type 1 dissecting aortic aneurysm with right coronary artery perfused by false lumen of ascending aorta and with congestive heart failure due to aortic insufficiency without discernible risk factor. Medical and surgical treament(Modified Bentall's operation) were successfully performed. The pathologic report showed combined cystic medial necrosis. Now he is well tolerated and stable only with anticoagulation during follow up 18 months.

  • PDF

Favorable Aortic Remodeling Following Serial False Lumen Procedures in a Case of Chronic Type IIIb Dissection

  • Eleshra, Ahmed Sameh;Heo, Woon;Lee, Kwang-Hun;Lee, Shin-Young;Lee, Ha;Song, Suk-Won
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.286-289
    • /
    • 2018
  • We report a case of acute type I aortic dissection in which an emergency graft replacement of the ascending aorta and innominate artery was performed. We performed false lumen thrombosis through hybrid thoracic endovascular aortic repair to seal the primary entry tear, followed by false lumen obliteration at the level of the descending thoracic aorta, abdominal aorta, and right common iliac artery. Over a period of 4.5 years, we used Amplatzer vascular plugs and coils based on our computed tomography angiography follow-up protocol.

Sialolithiasis Mimicking Metastatic Thyroid Cancer (갑상선암 전이병소로 오인된 타석증 증례)

  • Jeong, Hwan-Jeong;Bom, Hee-Seung;Song, Ho-Cheon;Min, Jung-Jun;Kim, Seung-Min;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.94-98
    • /
    • 2000
  • We report a false positive case of I-131 scan due to a sialolithiasis in right submandibular gland. I-131 images showed not only remnant thyroid tissues and functional metastases in the anterior neck but also a hot uptake near right submandibular gland. We confirmed the sialolithiasis by radiologic studies. Sialolithiasis should be regarded as a false positive cause when I-131 scan shows a hot spot near salivary bed.

  • PDF

Accuracy of Preoperative Computed Tomography in Comparison with Histopathologic Findings in Staging of Lung Cancer (폐암의 병기결정시 임파절의 조직학적 소견과 전산화단층활영의 정확도에 관한 고찰)

  • 박기진;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.1
    • /
    • pp.52-58
    • /
    • 1996
  • Sixty six patients who were operated as lung cancer during the period from Mar. 1991 to Sep. 1993 at the department of Thoracic and cardiovascular surgery, were reviewed retrospectively and the accuracy of regional lymph node in preoperative CT were compared with histopathologlc report obtained from operation. The age ranged from 30 to 72 years old (mean age : 56.5), and 51 patients were male and 15 patients were female. The author analysed the true positive, true negative, false positive and false negative and sensitivity, specificity, positive predictive index, negative predictive index and accuracy of each nodes. The result is that there were differences between seven nodal groups in specificity, sensitivity, positive predictive Index, negative predictive index and accuracy. The range of each nodal group is from 81.7 to 98.3% The nodes of the most poor accuracy are aortopulmonary area and hilar area.

  • PDF

Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case- (동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

A Case of Lobular Capillary Hemangioma at the False Vocal Cord With Intermittent Stridor

  • Park, Sang-Wook;Cho, Ki Ju;Won, Seongjun;Park, Jung Je
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.3
    • /
    • pp.150-152
    • /
    • 2021
  • Lobular capillary hemangioma (LCH) is a type of benign vascular tumor. It arises from vascular endothelial cells and contains capillaries arranged in a lobular pattern. In the head and neck, the most common presenting location of LCH is the lips, and presentation in the larynx is very rare. LCH might not be distinct from granuloma in macroscopic views. We report a 71-year-old female with LCH of the larynx that was totally resected via laryngeal microsurgery with a CO2 laser and briefly review the literature.

Fuzzy Logic based Next Hop Node Selection Method for Energy Efficient PVFS in WSN (무선 센서 네트워크에서 확률적 투표 기반 여과 기법의 에너지 효율성을 위한 퍼지 로직 시스템 기반의 다음 이웃 노드 선택 기법)

  • Lee, Jae Kwan;Nam, Su Man;Cho, Tae Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.23 no.2
    • /
    • pp.65-72
    • /
    • 2014
  • Sensor nodes are easily compromised by attacker when which are divided in open environment. The attacker may inject false report and false vote attack through compromised sensor node. These attacks interrupt to transmission legitimate report or the energy of sensor node is exhausted. PVFS are proposed by Li and Wu for countermeasure in two attacks. The scheme use inefficiency to energy of sensor node as fixed report threshold and verification node. In this paper, our propose the next neighbor node selection scheme based on fuzzy logic system for energy improvement of PVFS. The parameter of fuzzy logic system are energy, hops, verification success count, CH select high the next neighbor node among neighbor nodes of two as deduction based on fuzzy logic system. In the experimental, our proposed scheme was improvement to energy of about 9% compare to PVFS.