• Title/Summary/Keyword: False Detection

Search Result 1,207, Processing Time 0.033 seconds

Multi-view Image Generation from Stereoscopic Image Features and the Occlusion Region Extraction (가려짐 영역 검출 및 스테레오 영상 내의 특징들을 이용한 다시점 영상 생성)

  • Lee, Wang-Ro;Ko, Min-Soo;Um, Gi-Mun;Cheong, Won-Sik;Hur, Nam-Ho;Yoo, Ji-Sang
    • Journal of Broadcast Engineering
    • /
    • v.17 no.5
    • /
    • pp.838-850
    • /
    • 2012
  • In this paper, we propose a novel algorithm that generates multi-view images by using various image features obtained from the given stereoscopic images. In the proposed algorithm, we first create an intensity gradient saliency map from the given stereo images. And then we calculate a block-based optical flow that represents the relative movement(disparity) of each block with certain size between left and right images. And we also obtain the disparities of feature points that are extracted by SIFT(scale-invariant We then create a disparity saliency map by combining these extracted disparity features. Disparity saliency map is refined through the occlusion detection and removal of false disparities. Thirdly, we extract straight line segments in order to minimize the distortion of straight lines during the image warping. Finally, we generate multi-view images by grid mesh-based image warping algorithm. Extracted image features are used as constraints during grid mesh-based image warping. The experimental results show that the proposed algorithm performs better than the conventional DIBR algorithm in terms of visual quality.

Usefulness of Scan Position Change on Dual Time Point PET-CT in Pancreas Cancer (췌장암 Dual Time Point PET/CT 검사에서 Scan Position Change의 유용성 평가)

  • Chang, Boseok;Kim, Jae Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.299-305
    • /
    • 2016
  • Despite of the development of medical equipments and technology. Pancreatic cancer has maked high false positive rate and low survival rate compared to other cancers. Therefore, early catch of pancreatic cancer is the only way to enhance the viability. It is important to find the exact location of the pancreas cancer in early stage. The method of optimum scan for early detection of pancreatic cancer on PET/CT exam is proposed. Examined the anatomical region that potentially can be missing from the supine position of ordinary pet/ct exam. The characteristics and usefulness of angle variation ($0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$) of patients scan position is analyzed. The proposed scan method (named JJ-projection) is bringing advantage of anatomical discrimination by separating stomach, liver, gallbladder duodenum and pancreas. ROC curve analysis is shows to advantage of the JJ-Projection method. The sensitivity has increased 4.6% than the supine delay scan method, the results sensitivity has increased from 91% to 95.2%. The specificity has increased from 75.1% to 84%. Compared with the results observed in cancer by biological biopsy, The accuracy has increased from 86.8% to 94.1%.

MLPA Applications in Genetic Testing (유전자진단에 있어서 Multiplex Ligation Dependent Probe Amplification (MLPA)의 이론과 실제)

  • Kim, Gu-Hwan;Lee, Beom-Hee;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.6 no.2
    • /
    • pp.146-154
    • /
    • 2009
  • Multiplex ligation dependent probe amplification (MLPA) is a PCR-based method to detect gene dosage. Since its introduction, MLPA has been used to test a large number of genes for major deletions or duplications. Genetic testing, as a diagnostic tool for genetic disease, has been used primarily to identify point mutations, including base substitutions and small insertions/deletions, using PCR and sequence analysis. However, it is difficult to identify large deletions or duplications using routine PCR- gel based assays, especially in heterozygotes. The MLPA is a more feasible method for identification of gene dosage than another routine PCR-based methods, and better able to detect deleterious deletions or duplications. In addition to detection of gene dosage, MLPA can be applied to identify methylation patterns of target genes, aneuploidy during prenatal diagnoses, and large deletions or duplications that may be associated with various cancers. The MLPA method offers numerous advantages, as it requires only a small amount of template DNA, is applicable to a wide variety of applications, and is high-throughput. On the other hand, this method suffers from disadvantages including the possibility of false positive results affected by template DNA quality, difficulties identifying SNPs located in probe sequences, and analytical complications in quantitative aspects.

  • PDF

Detecting near-duplication Video Using Motion and Image Pattern Descriptor (움직임과 영상 패턴 서술자를 이용한 중복 동영상 검출)

  • Jin, Ju-Kyong;Na, Sang-Il;Jenong, Dong-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.4
    • /
    • pp.107-115
    • /
    • 2011
  • In this paper, we proposed fast and efficient algorithm for detecting near-duplication based on content based retrieval in large scale video database. For handling large amounts of video easily, we split the video into small segment using scene change detection. In case of video services and copyright related business models, it is need to technology that detect near-duplicates, that longer matched video than to search video containing short part or a frame of original. To detect near-duplicate video, we proposed motion distribution and frame descriptor in a video segment. The motion distribution descriptor is constructed by obtaining motion vector from macro blocks during the video decoding process. When matching between descriptors, we use the motion distribution descriptor as filtering to improving matching speed. However, motion distribution has low discriminability. To improve discrimination, we decide to identification using frame descriptor extracted from selected representative frames within a scene segmentation. The proposed algorithm shows high success rate and low false alarm rate. In addition, the matching speed of this descriptor is very fast, we confirm this algorithm can be useful to practical application.

Detection of Canine Lymphoma by the Amplification of Antigen Receptor Gene Rearrangements (재배열 항원 수용체 유전자 증폭을 통한 개 림프종의 진단)

  • Yu, Do-Hyeon;Li, Ying-Hua;Lee, Jong-Hyun;Noh, Dong-Ho;Song, Ru-Hui;Lee, Mi-Jin;Choi, Ul-Soo;Park, Jin-Ho
    • Journal of Veterinary Clinics
    • /
    • v.26 no.5
    • /
    • pp.419-422
    • /
    • 2009
  • We performed the PARR (PCR to detect antigen receptor rearrangements) test on DNA isolated from twelve archival canine cytological slides including nine lymphoma, two reactive lymphocytes and one sample from Ehrlichia canis infected dog. As a result, our PCR control gene, $C{\mu}$, was successfully amplified from all of the DNA samples. Six out of nine lymphoma samples showed a clonal rearrangement of immunoglobulin gene whereas three samples did a clonal rearrangement of T cell receptor gamma ($TCR{\gamma}$) gene. However, we observed no visible or clear bands from PCR conducted using our antigen receptor rearrangement primers on DNA from a reactive lymphoid cell proliferation used as a negative control. False-positive amplification in $TCR{\gamma}$ gene was observed only in one sample from E. canis infection. The use of archival cytological specimens demonstrated in this study offers potential advantages for cost-effective specimen acquisition and efficient high-fidelity DNA analysis.

A Twin diagnosed with Duarte Variant/Classical (D/G) Galactosemia (Duarte Variant/Classical Galactosemia (D/G) Heterozygote으로 진단된 일란성 쌍둥이 1례)

  • Koo, Kyo Yeon;Lee, Chul Ho;Yang, Jeong Yoon;Lee, Jin-Sung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.12 no.1
    • /
    • pp.58-63
    • /
    • 2012
  • Classical galactosemia (OMIM# 230400) is an autosomal recessive disorder of carbohydrate metabolism, due to a complete loss in galactose-1-phosphate uridyltransferase (GALT; E.C.2.7.7.12) enzyme activity. It caused by mutations in the GALT gene (OMIM$^*$ 606999) that is located at chromosome 9p13. The GALT enzyme deficiency results in a build-up of galactose and galactose-1-phosphate, causing life threatening complications such as feeding problems, failure to thrive, hepatocellular damage, bleeding and sepsis. However, Duarte galactosemia, a variant form of GALT deficiency, has residual GALT enzyme activities in erythrocytes and do not have manifest the symptoms of classical galactosemia. Since the advent of newborn screening (NBS) for galactosemia, we rarely encounter such overwhelmingly ill newborns. The positive NBS with no symptoms indicates the possibility of Duarte galactosemia besides a simple false positive and it has to be differentiated from classical galactosemia which is a medical emergency. In Korea, detection rate of Duarte galactosemia is very low and its genetic information is restrictive, too. We report a case of monozygotic twins with D/G galactosemia compound heterozygote in proven by the mutational analysis of GALT gene, which revealed N314D polymorphism and -119 to -116 delGTCA.

  • PDF

Identification of Hanwoo (Korean Native Cattle) Beef in Restaurants using Real-time PCR (시중 음식점에서 판매되는 쇠고기의 유전자 분석을 이용한 한우육 감별)

  • Kim Jin-Man;Nam Yong-Suk;Choi Ji-Hun;Lee Mi-Ae;Jeong Jong-Yon;Kim Cheon-Jei
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.203-209
    • /
    • 2005
  • Real time-polymerase chain reaction (RT-PCR) is currently considered as the most sensitive method to detect low abundant DNAs in samples. Compared to conventional PCR, real-time PCR has a high reliability because of excluding false-positive results and can allow a simultaneous faster detection and quantification of target DNAs. This study was carried out to identify the Hanwoo (Korean native cattle) beef by genotyping after DNA extraction of commercial beef in 41 restaurants. Since Hanwoo, Holstein and imported cattle meat have different patterns in the MC1R gene associated with the coat colors of cattles (C-type, C/T-type or T-type), we could identify the genotype using real-time PCR The result of real-time PCR assay for beef samples in 41 restaurants which are asserted to sell Hanwoo beef only, showed that 29 of 41 samples were Hanwoo beef gene type (T-type) and 12 of 41 samples were Holstein or imported cattle gene type (C-type or C/T-type). Therefore, the proportion of Han-woo beef was $70.7\%$ and the proportion of Holstein or imported cattle meat was $29.3\%(C/T-type; 12.2\%,\;C-type; 17.1\%)$.

Comparison of Diagnostic Accuracy for Detecting Coronary Artery Disease of Dipyridamole $^{99m}Tc$-MIBI Myocardial SPECT and It's Defect Map between Men and Women (디피리다몰 부하 $^{99m}Tc$-MIBI 심근 SPECT 극성결손지도를 이용한 관동맥질환 진단의 남녀 비교)

  • Bae, Sang-Kyun;Lee, Dong-Soo;Oh, Byung-Hee;Chung, June-Key;Lee, Myoung-Mook;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.59-64
    • /
    • 1993
  • To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole $^{99m}Tc$-MIBI myocardial SPECT, we obtained $^{99m}Tc$-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole $^{99m}Tc$-MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex (LCX) and 8% for right coronary artery (RCA) territories. Lesions${\geqq}$50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns): specificity was 84.6% in men and 67.9% in women (P < 0.025). For individual coronary artery, the sensitivity in men and women was 87.7%, 81.8% for LAD; 78%, 83.3% for RCA and 52.2%, 46.7% for LCX (P=ns): the specificity was 80%, 40% for LAD (P<0.01), 82.5%, 68.4% for RCA, 88.9%, 86.4% for LCX (P=ns). The hemodynamic parameter after intravenous dipyridamole in men and women were significantly changed; the heart rate was increased and systolic, diastolic blood pressure was decreased. Adverse effects were reported in 58.8% of men and 72.7% in women (P=ns). The incidence of chest pain and headache were higher in women. There was no significant difference in the incidences of nausea, abdominal pain, dizziness, facial flushing, dyspnea. In conclusion, dipyridamole $^{99m}Tc$-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  • PDF

Comparison of Photostimulated Luminescence, Thermoluminescence, and Electron Spin Resonance Spectroscopic Analyses on Dried-spices Irradiated by Gamma Ray and Electron Beam (감마선 및 전자선 조사 처리 건조향신료에 대한 광자극발광, 열발광 및 전자스핀공명의 분광학적 분석 비교)

  • Jeong, Jin-Hwa;Ahn, Jae-Jun;Baek, Ji-Yeong;Kim, Hyo-Young;Kwon, Joong-Ho;Jin, Chang-Hyun;Jeong, Il-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.256-261
    • /
    • 2014
  • This study was conducted to determine the effect of gamma-ray and electron-beam irradiation on dried spices (black pepper, red pepper, parsley, and basil) using the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods. The spices were irradiated at 0, 1, 5, and 10 kGy. All non-irradiated spices had photon counts (PCs) less than 700 PCs. The PCs of three irradiated spices (red pepper, parsley, and basil) were clearly distinguishable from those of non-irradiated ones, exhibiting PSL signals higher than 5000 PCs. However, negative PSL counts (<700 PCs) were obtained for most irradiated black pepper, except those irradiated with 5 kGy gamma rays and 10 kGy electron-beams. TL glow curves of the irradiated spices showed a higher peak at $150-250^{\circ}C$. TL ratios were found to be less than 0.1 for non-irradiated spices and higher than 0.1 for irradiated ones. No ESR signal was observed for any irradiated spice except red pepper, which displayed cellulose-based ESR spectra. Therefore, the results suggest that the PSL, TL, and ESR methods are effective detection techniques for dried spices irradiated with electron beams as well as gamma rays.

Quilitative certificational plan of heshouwu (하수오(何首烏)의 품질인증(品質認證) 방안(方案))

  • Shin, Mi-Kyung;Roh, Seong-Soo;Kil, Ki-Jeong;Seo, Bu-il;Seo, Young-Bae
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.205-212
    • /
    • 2004
  • Now many sustitution and false articles is used in korea instead of heshouwu. To use heshouwu correctly, we will make a quilitative certificational plan of heshouwu to investigate all of lieraturea, records and documents. And we could reach conclusions as folloews. 1) Source of plant Heshouwu is a root tuber of a perennial herb Polygonum multiflorum Thunberg(Family : Polygonaceae). 2) Harvest After planting 3-5 yaers, harvesting in an autumn, washin clean the mud, a big heshouwu cut off a half or section, dry in sunny place or at a little fire. When harvesting, we harvest only a big thing, a small thing transfer a field, after culturing of 1-2 years, harvest at big roots. Harvesting is done usually in an autumn after 3 years. When collecting a seed, we must harvest a heshouwu the next year. 3) Process We must process heshouwu at the decoction of black beans, heshouwu suck in the decoction of black beans, heat with steam in an iron pot. Black beans is used every 100 kg of heshouwu. 4) Quility (1) Funstional standards It is good that weight is heavy and outer skin is yellow-brown, section surface is light red color, powdery and has a figure such as clouds in section. (2) Physicochemical standards Heshouwu expesses a various chang of components in process of working. We think that it need to add a standard of detection about 2,3,5,4'-tetrahrdroxystilbene-2-O-${\beta}$ -D-glucoside in a current authentic document which is a water-soluble component of heshouwu. It must that Dry on loss is less than 14.0%, content of ash is less than 5.0%, Content of acid-nonsoluble ash is less than 1.5%, Content of extract is more than 17.0%. A fixed quantity of 2,3,5,4'-tetrahrdroxystilbene-2-O-${\beta}$ -D-glucoside is more than 1.0%. Contens of heavy metal has to detect less than 30 ppm and there is no reminding agriculural medince.

  • PDF