• Title/Summary/Keyword: Failure rate test

Search Result 527, Processing Time 0.028 seconds

A study of lifetime prediction of PV module using damp heat test (고온고습 시험을 이용한 실리콘 태양전지 모듈의 수명 예측 연구)

  • Oh, Won Wook;Kang, Byung Jun;Park, Nochang;Tark, Sung Ju;Kim, Young Do;Kim, Donghwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.63.1-63.1
    • /
    • 2011
  • To analyze the phenomenon of corrosion in the PV module, we experimented damp heat test at $85^{\circ}C$/85% relative humidity(RH) and $65^{\circ}C$/85% RH for 2,000 hours, respectively. We used 30 mini-modules designed of 6inch one cell. Despite of 2,000 hours test, measured $P_{max}$ is not reached failure which is defined less than 80% compared to initial $P_{max}$. Therefore, we calculate proper curve fitting over 2,000 hours. Data less than 80% $P_{max}$ is found and B10 lifetime is calculated by the number of failure specimens and weibull distribution. Using B10 lifetime that the point of failure rate 10% and Peck's model, the predictable equation of lifetime was derived under temperature and humidity condition.

  • PDF

A Study on Reliability Improvement of Avionics Equipment (항공전자 장비 신뢰도 향상 방안 연구)

  • Seo, Joon-Ho;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.383-386
    • /
    • 2017
  • Avionics, a type of embedded system, requires high safety and reliability. Failure of avionics equipment can have a significant impact on aircraft operations and, in the worst case, could result in loss of life for pilots and passengers. In this paper, we propose a Built-In-Test (hereafter referred to as BIT) design technique that can detect possible faults in avionics equipments in order to increase the reliability of avionics system and a design that can improve the Mean Time Between Failure (hereafter: MTBF) and applied it to real aviation electronic equipment to improve reliability.

  • PDF

Influence of Home Based Exercise Intensity on the Aerobic Capacity and 1 Year Re-Hospitalization Rate in Patients with Chronic Heart Failure

  • Ryu, Ho Youl;Kim, Ki Song;Jeon, In Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.181-186
    • /
    • 2018
  • Purpose: This study investigated the effects of home-based exercise intensity on the aerobic capacity and 1 year re-hospitalization rate in patients with chronic heart failure (CHF). Methods: Forty seven patients with CHF (males 33, females 14, age $61.3{\pm}9.8years$) participated in this study. The patients were allocated randomly to 3 groups in accordance with home-based exercise intensity: no home based exercise (NHE, 40%, n=19), moderate intensity home-based exercise (MIHE, 43%, n=20), and high intensity home based exercise (HIHE, 17%, n=8). All patients completed the symptom-limited cardiopulmonary exercise (CPX) test safely at the cardiac rehabilitation hospital. Results: The NHE group significantly showed lower peak $VO_2$ and a higher $VE/VCO_2$ slope than the MIHE (p<0.05) and HIHE (p<0.01) groups. On the other hand, the NHE group did not show significant differences in the other hemodynamic responses, such as heart rate (HR) max, HR reserve, maximal systolic blood pressure (SBP), and SBP reserve. Nine out of 19 NHE patients (47%) were re-hospitalized related to heart disease and two out of 20 MIHE (10%) patients were re-hospitalized, but nobody in the HIHE group were re-hospitalized within 1 year from the CPX test. Conclusion: In patients with CHF, home-based self-exercise is one of the important factors for reducing the re-hospitalization rate. In addition, improved aerobic capacity is strongly associated with a lower re-hospitalization rate. In particular, re-hospitalized CHF patients showed significant differences in respiratory parameters and hemodynamic parameters compared to the non-re-hospitalized patients.

Failure Prediction of Metal Oxide Varistor Using Nonlinear Surge Look-up Table Based on Experimental Data

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.317-322
    • /
    • 2015
  • The metal oxide varistor (MOV) is a major component of the surge protection devices (SPDs) currently in use. The device is judged to be faulty when fatigue caused by the continuous inflow of lightning accumulates and reaches the damage limit. In many cases, induced lightning resulting from lightning strikes flows in to the device several times per second in succession. Therefore, the frequency or the rate at which the SPD is actually exposed to stress, called a surge, is outside the range of human perception. For this reason, the protective device should be replaced if it actually approaches the end of its life even though it is not faulty at present, currently no basis exists for making the judgment of remaining lifetime. Up to now, the life of an MOV has been predicted solely based on the number of inflow surges, irrespective of the magnitude of the surge current or the amount of energy that has flowed through the device. In this study, nonlinear data that shows the damage to an MOV depending on the count of surge and the amount of input current were collected through a high-voltage test. Then, a failure prediction algorithm was proposed by preparing a look-up table using the results of the test. The proposed method was experimentally verified using an impulse surge generator

Research for Modeling the Failure Data for a Repairable System with Non-monotonic Trend (복합 추세를 가지는 수리가능 시스템의 고장 데이터 모형화에 관한 연구)

  • Mun, Byeong-Min;Bae, Suk-Joo
    • Journal of Applied Reliability
    • /
    • v.9 no.2
    • /
    • pp.121-130
    • /
    • 2009
  • The power law process model the Rate of occurrence of failures(ROCOF) with monotonic trend during the operating time. However, the power law process is inappropriate when a non-monotonic trend in the failure data is observed. In this paper we deals with the reliability modeling of the failure process of large and complex repairable system whose rate of occurrence of failures shows the non-monotonic trend. We suggest a sectional model and a change-point test based on the Schwarz information criterion(SIC) to describe the non-monotonic trend. Maximum likelihood is also suggested to estimate parameters of sectional model. The suggested methods are applied to field data from an repairable system.

  • PDF

Type-II stepwise progressive censoring

  • Bayat, Mohammad;Torabi, Hamzeh
    • Communications for Statistical Applications and Methods
    • /
    • v.23 no.1
    • /
    • pp.57-70
    • /
    • 2016
  • Type-II progressive censoring is one of the censoring methods frequently used in clinical studies, reliability trials, quality control of products and industrial experiments. Sometimes in Type-II progressive censoring experiments, the failure rate is low so the waiting time to observe the $m^{th}$ failure will be very long; however, the experimenter may have to terminate the experiment before a predetermined time. In this article, if two generalized types of Type-II progressive censoring are reminded, we then make some changes in the removal method of Type-II progressive censoring such that without reducing the deduction quality, the termination time of the experiment decreases. This can be done with decreasing withdraws throughout the steps of the experiment with a special reasonable method. A simulation study is done and the results are tabulated at the end of this article for a comparison between introduced method and Type-II progressive censoring.

Analysis of Leak and Water Absorption Test Results for Water-Cooled Generator Stator Windings

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Wook-Ryun;Lee, Doo-Young;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.230-235
    • /
    • 2012
  • Cases of insulation breakdown damage of water-cooled generator stator windings occur frequently due to coolant leakage and water absorption worldwide. Such serious accidents may cause not only enormous economic loss but also very serious grid accidents in terms of stable supply of electric power. More than 50 % of domestic generators have been operated for more than 15 years, and leak and water absorption problem of windings are often found during the planned preventive maintenance period. Since 2005, leak and water absorption tests have been performed for total watercooled stator windings after fully drying the inside of the windings. The results are then comprehensively analyzed. The result of the test performed by GE, a foreign manufacturer, for 141 generators showed failures in 80 of them (failure rate: 57 %), whereas in the tests carried out in Korean domestic power plants, only 14 out of 50 generators showed failures (failure rate: 28 %).

LTE Mobility Enhancements for Evolution into 5G

  • Park, Hyun-Seo;Choi, Yong-Seouk;Kim, Byung-Chul;Lee, Jae-Yong
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1065-1076
    • /
    • 2015
  • Network densification is regarded as the dominant driver for wireless evolution into the era of 5G. However, in this context, interference-limited dense small cell deployments are facing technical challenges in mobility management. The recently announced results from an LTE field test conducted in a dense urban area show a handover failure (HOF) rate of over 21%. A major cause of HOFs is the transmission failure of handover command (HO CMD) messages. In this paper, we propose two enhancements to HO performance in LTE networks - radio link failure-proactive HO, which helps with the reliable transmission of HO CMD messages while the user equipment is under a poor radio link condition, and Early Handover Preparation with Ping-Pong Avoidance (EHOPPPA) HO, which assures reliable transmission of HO CMD under a good radio link condition. We analyze the HO performance of EHOPPPA HO theoretically, and perform simulations to compare the performance of the proposed schemes with that of standard LTE HO. We show that they can decrease the HOF rate to nearly zero through an analysis, and based on the simulation results, by over 70%, without increasing the ping-pong probability.

A Study on the Optimal Sampling for Predicting Failure Rate of One-Shot Weapon Systems (원샷 무기체계 고장률 예측을 위한 최적 샘플링 방안 연구)

  • Ahn, Joo Han;Ma, Jungmok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.366-372
    • /
    • 2020
  • The Army's rocket missile is a one-shot weapon system, which is produced and used for only one mission, and requires high reliability. While reliability analysis with failure data can result in underestimation of the life distribution, reliability analysis with all the non-failure data can result in overestimation of the life distribution. Under or overestimation of the life distribution can lead to cost increase by early disposal or complete observation of all rocket missiles. In order to overcome this problem, the Army suggests the guideline of the number of samples from non-failure data for reliability analysis with failure data. However, the currently used sampling method can generate errors for predicting the failure rate. To solve this problem, this study proposes a new sampling procedure for predicting a future failure rate using non-failure data. The comparison test between the currently used sampling method and the proposed sampling method is conducted and the result shows that the proposed sampling method can predict the future failure rate more accurately.

Effect of Electromagnetic Navigated Ventriculoperitoneal Shunt Placement on Failure Rates

  • Jung, Nayoung;Kim, Dongwon
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.150-154
    • /
    • 2013
  • Objective : To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. Methods : All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. Results : A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). Conclusion : The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.