• Title/Summary/Keyword: Failure rate test

Search Result 527, Processing Time 0.027 seconds

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

The Effects of a Nutrition Education Program for Hypertensive Female Elderly at the Public Health Center (고혈압 여자 노인 대상의 보건소 영양교육 효과 분석)

  • Yim, Kyeong-Sook
    • Korean Journal of Community Nutrition
    • /
    • v.13 no.5
    • /
    • pp.640-652
    • /
    • 2008
  • Hypertension is among the most common and important risk factors for stroke, heart attack, and heart failure which is considered to be the leading cause of death in Korea. The prevalence rate of hypertension in Korea is 27.9%, according to the 2006 Korea National Health and Nutrition Survey. Since non-pharmacologic nutrition education is recommended as the first step in the management of hypertension, evaluation of nutrition program is needed to form strategies for improving patients' dietary adherence. This study was designed to evaluate the overall effectiveness of a hypertension nutrition education program (HNEP) for reducing the salt intake, at a public health center located in Gyunggi-province. The HNEP was offered for 16 weeks from May to September in 2007. Nutrition education activities included cooking classes, food preparation demonstrations, physical fitness programs, salty taste preference test sessions, games, case-study presentations, planning and evaluation of menus, etc. Forty patients participated fully in the program which had 47 female enrollees. Data about nutrient intake (24-hour recall), nutrition knowledge, food behavior were collected before (baseline) and after the program. Changes after program completion indicated the following: 1) diastolic blood pressure was decreased (p < 0.05), 2) sodium (salt) intake was also decreased (p < 0.01), especially baseline high salt intake group, 3) nutrition knowledge was improved (p<0.001), 4) dietary behaviors for maintaining a low salt diet was improved (p < 0.001), 5) participants preferred cooking class from nutrition education methods. As a conclusion, it appears that a nutrition education program for hypertensive female elderly for reducing the salt intake might effectively decrease blood pressure and salt intake. It also improves nutrition knowledge, dietary behavior, and finally adherence to a recommendable low-sodium diet.

Development of Automatic Alignment Height and Cross-section Inspection System for Fiber Bragg Grating Embedded Field Assembly Connector (FBG Embedded 현장 조립형 커넥터의 자동 정렬 및 단면 자동 검사 시스템 개발)

  • Lee, Jung-Ho;Park, Chan-Hee;Yoon, Jae-Soon;Lee, Hee-Kwan;Kim, Cheol-Sang;Kim, Jae-Won;Kim, Kyung;Kim, Jae-Jun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.94-101
    • /
    • 2014
  • Recently, in order to reduce the time required to replace an optical jumper cord, many researchers are using a field-installable connector and applying the ferrule polishing method, ferrule mechanical contact method, or ferrule fusion contact method. However, the process of arranging the length of the optical fiber, i.e., inserting the optical fiber into the ferrule by hand and checking its cross section, takes 60% of the time required for the entire process, which increases the overall cost. Therefore, in order to make this task more cost-effective, we will develop an automated inspection system with automatic cross-sectional arrangement of a field-installable connector. This system will be able to decrease the failure rate from 10% to 2% compared with the conventional method when cutting the optical fiber inserted into the ferrule. It will also improve the productivity by decreasing the test time by 28% compared with the conventional method. Our studies showed that it was possible to reduce the production costs and improve the quality of a field-installable connector, and we expect it to dominate the market.

An Improvement Study on Brake System for KUH-1 (한국형 기동헬기의 제동장치 개선에 관한 연구)

  • Choi, Jae Hyung;Lim, Hyun-Gyu;Yoon, Jong Jin;Kang, Deuk Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.292-299
    • /
    • 2017
  • The KUH-1's Wheel Brake Assembly which is Brake System is an essential component to perform flight mission for pilot. It has function of taxing, differential braking and parking to sustain landing capability. However, the skid and abrasion of tire were occurred in mass-produce operation. Also, if it is occurred on the ground, the flight can not be performed. In this case, the defect is a major cause of the decrease in the operation rate of aircraft. In this paper, the cause of the defect in flight was identified and the failure process was organized. Also, it describes design improvements which was derived from troubleshooting and suggests verification results of flight test.

The Effect of Nano Functionalized Block Copolymer Addition on the Joint Strength of Structural Epoxy Adhesive for Car Body Assembly (차체 구조용 에폭시 접착제의 접합강도에 미치는 나노 기능성 블록공중합체 첨가의 영향)

  • Lee, Hye-rim;Lee, So-jeong;Lim, Chang-young;Seo, Jong-dock;Kim, Mok-soon;Kim, Jun-ki
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.44-49
    • /
    • 2015
  • The structural epoxy adhesive used in car body assembly needs the highest level of joint mechanical strength under lap shear, T-peel and impact peel conditions. In this study, the effect of nano functionalized block copolymer addition on the impact peel strength of epoxy adhesive was investigated. DSC analysis showed that the addition of nano functionalized block copolymer did not affect the curing reaction of epoxy adhesive. From single lap shear test, it was found out that the addition of nano functionalized block copolymer slightly decreased the cohesive strength of cured adhesive layer. The addition of nano functionalized block copolymer showed beneficial effect on T-peel strength by changing the adhesive failure mode to the mixed mode. However, the addition of nano functionalized block copolymer just decreased the room temperature impact peel strength. It was considered that the addition of nano functionalized block copolymer could have effect on disturbing the crack propagation only for the case of slow strain rate.

Use of Massive Cuff Stitch in Arthroscopic Repair of Rotator Cuff Tears (관절경 하 회전근 개 파열의 봉합에서 광범위 근개 봉합법의 이용)

  • Ko, Sang-Hun;Cho, Sung-Do;Gwak, Chang-Youl;Eo, Jin;Yoo, Chang-Hyun;Choe, Seung-Wan
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.181-188
    • /
    • 2006
  • Purpose: To evaluate the integrity of repair & technical tip in use of Massive Cuff Stitch at arthroscopic repair of rotator cuff tear. Materials and Methods: Twenthy-nine cases of arthroscopically repaired full thickness tear of rotator cuffs which are medium sized were evaluated. Between December 2004 to September 2005 we have studied, the average age 53($42{\sim}69$) years old, mean follow-up was 15($12{\sim}21$) months. We analyzed the results statistically by paired t-test. The integrity of repair were verified by follow up MRI which were checked 11 cases and ultrasound which were checked 10 cases. Results: VAS of pain improved preoperative average 7.1 to postoperative 0.9, ADL improved 11.2 to 25.6 respectively, UCLA improved 13.7 to 32.9(all, P<0.05). 89.7% showed excellent & good results at the final follow-up. The satisfied rate was 93.1%(27 cases). There was re-rupture of the repaired rotator cuff in one case out of 11 cases which were checked by MRI, and in one case out of 10 cases which were checked by ultrasound, and there was one case of thinning of cuff which were checked by ultrasound. Conclusion: The use of Massive Cuff Stitch in arthroscopic repair of rotator cuff tear have been reduced technical failure. It will be good surgical technique which maintain the integrity of repairs.

The Effect of Composite Incompatibility on Relationship Commitment and Performances in Franchiser-Franchisee Relationship (프랜차이즈 가맹본부와 가맹점 간 이해관계불일치가 관계몰입과 관계성과에 미치는 영향)

  • Yi, Ho-Taek
    • Journal of Distribution Science
    • /
    • v.15 no.2
    • /
    • pp.91-100
    • /
    • 2017
  • Purpose - Domestic franchise market has been grown steadily, reaching 50 trillion won in sales and 3,360 franchise headquarters in 2014. A franchise system is an effective business system for the franchisees to lower the failure rate due to the fact that the inexperienced entrepreneurs are supported by their headquarters through the franchisee contract. However, there are also conflicts between franchiser and franchisee behind the quantitative growth of domestic franchise industry. Therefore, it is very important to structure the causes of conflicts and to examine the effect of factors on the relationship commitment and performances. Research design, data, and methodology - In this study, the author divides the composite incompatibility between the franchise and the franchisee into goal incongruity, domain dissensus, and perceptual differences, and examines each dimension to the relationship with commitment and performances. To verify the proposed research model and test hypotheses, the author selected 200 franchise responses in food and beverage industry. The data were analyzed using SPSS 18.0 and AMOS structural equation modeling program. Results - The empirical findings provide goal incongruity and perceptual differences have a negative effect on the affective commitment, but not the calculative commitment. In addition, affective commitment and calculative commitment are found to have a positive effect on re-contractual intention and extended brand shop running intention, respectively. Affective commitment have a stronger effect on re-contractual intention than calculative commitment. Conclusions - First of all, the fact that goal incongruity and perceptual differences negatively affect the affective commitment, but it does not affect the calculative commitment. It means the relationship commitment in distribution channel are multi-dimensional concept that may be attributed to emotional or affective dimensions but may exist in terms of necessity or power-dependence. Second, the level of relationship commitment such as affective and calculative commitment to franchise headquarters positively affects the re-contractual intention and franchiser's extend brand shop running intention suggest that franchiser should encourage and support existing franchisee's commitment. Third, the fact that affective commitment has a greater effect on relationship performance than calculative commitment means to induce franchisee's affective commitment and to prevent the inconsistency between goals and perceptual differences.

The shear strength of RC rectangular sectional columns considering displacement ductility (변위연성도를 고려한 RC 사각단면 기둥의 전단강도)

  • Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.37-47
    • /
    • 2010
  • In order to attain enhanced seismic performance of RC bridges, premature shear failure prior to the achievement of target ductilities of the piers should be prevented. For this purpose, a reliable shear strength evaluation is required. The shear strength of an RC column subjected to a lateral force decreases with an increase in ductility. Many empirical equations for the shear strength have been proposed by many researchers. However, there are many discrepancies in the initial shear strength in the low ductility range, and in the decrease rate according to the ductility. In this study, a new empirical equation of shear strength considering the displacement ductility effect has been proposed, in which the initial shear strength equation proposed by the authors was revised on the basis of the investigation of many other researchers' test results. The resulting improvement in accuracy is confirmed by comparison with other empirical equations.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF