• Title/Summary/Keyword: Failure factor

Search Result 2,040, Processing Time 0.03 seconds

Shear strain behaviour due to twin tunnelling adjacent to pile group (군말뚝 기초 하부 병렬터널 굴착 시 전단변형 거동 특성)

  • Subin Kim;Young-Seok Oh;Yong-Joo Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.1
    • /
    • pp.59-78
    • /
    • 2024
  • In tunnel construction, the stability is evaluated by the settlement of adjacent structures and ground, but the shear strain of the ground is the main factor that determines the failure mechanism of the ground due to the tunnel excavation and the change of the operating load, and can be used to review the stability of the tunnel excavation and to calculate the reinforcement area. In this study, a twin tunnel excavation was simulated on a soft ground in an urban area through a laboratory model test to analyze the behavior of the twin tunnel excavation on the adjacent pile grouped foundation and adjacent ground. Both the displacement and the shear strain of ground were obtained using a close-range photogrammetry during laboratory model test. In addition, two-dimensional finite element numerical analysis was performed based on the model test. The results of a back-analysis showed that the maximum shear strain rate tends to decrease as the horizontal distance between the pillars of the twin tunnel and the vertical distance between the toe of the pile group and the crown of the tunnel were decreased. The impact of the second tunnel on the first tunnel and pile group was decreased as the horizontal distance between the pillars of the twin tunnel was increased. In addition, the vertical distance between the toe of the pile group and the crown of the tunnel had a relatively greater impact on the shear strain results than the horizontal distance of the pillars between the twin tunnels. According to the results of the close-range photogrammetry and numerical analysis, the settlement of adjacent pile group and adjacent ground was measured within the design criteria, but the shear strain of the ground was judged to be outside the range of small strain in all cases and required reinforcement.

A Study on the long-term Hemodialysis patient중s hypotension and preventation from Blood loss in coil during the Hemodialysis (장기혈액투석환자의 투석중 혈압하강과 Coil내 혈액손실 방지를 위한 기초조사)

  • 박순옥
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.2
    • /
    • pp.83-104
    • /
    • 1981
  • Hemodialysis is essential treatment for the chronic renal failure patient's long-term cure and for the patient management before and after kidney transplantation. It sustains the endstage renal failure patient's life which didn't get well despite strict regimen and furthermore it becomes an essential treatment to maintain civil life. Bursing implementation in hemodialysis may affect the significant effect on patient's life. The purpose of this study was to obtain the basic data to solve the hypotension problem encountable to patient and the blood loss problem affecting hemodialysis patient'a anemic states by incomplete rinsing of blood in coil through all process of hemodialysis. The subjects for this study were 44 patients treated hemodialysis 691 times in the hemodialysis unit, The .data was collected at Gang Nam 51. Mary's Hospital from January 1, 1981 to April 30, 1981 by using the direct observation method and the clinical laboratory test for laboratory data and body weight and was analysed by the use of analysis of Chi-square, t-test and anlysis of varience. The results obtained an follows; A. On clinical laboratory data and other data by dialysis Procedure. The average initial body weight was 2.37 ± 0.97kg, and average body weight after every dialysis was 2.33 ± 0.9kg. The subject's average hemoglobin was 7.05±1.93gm/dl and average hematocrit was 20.84± 3.82%. Average initial blood pressure was 174.03±23,75mmHg and after dialysis was 158.45±25.08mmHg. The subject's average blood ion due to blood sample for laboratory data was 32.78±13.49cc/ month. The subject's average blood replacement for blood complementation was 1.31 ±0.88 pint/ month for every patient. B. On the hypotensive state and the coping approaches occurrence rate of hypotension was 28.08%. It was 194 cases among 691 times. 1. In degrees of initial blood pressure, the most 36.6% was in the group of 150-179mmHg, and in degrees of hypotension during dialysis, the most 28.9% in the group of 40-50mmHg, especially if the initial blood pressure was under 180mmHg, 59.8% clinical symptoms appeared in the group of“above 20mmHg of hypotension”. If initial blood pressure was above 180mmHg, 34.2% of clinical symptoms were appeared in the group of“above 40mmHg of hypotension”. These tendencies showed the higher initial blood pressure and the stronger degree of hypotension, these results showed statistically singificant differences. (P=0.0000) 2. Of the occuring times of hypotension,“after 3 hrs”were 29.4%, the longer the dialyzing procedure, the stronger degree of hypotension ann these showed statistically significant differences. (P=0.0142). 3. Of the dispersion of symptoms observed, sweat and flush were 43.3%, and Yawning, and dizziness 37.6%. These were the important symptoms implying hypotension during hemodialysis accordingly. Strages of procedures in coping with hypotension were as follows ; 45.9% were recovered by reducing the blood flow rate from 200cc/min to 1 00cc/min, and by reducing venous pressure to 0-30mmHg. 33.51% were recovered by controling (adjusting) blood flow rate and by infusion of 300cc of 0,9% Normal saline. 4.1% were recovered by infusion of over 300cc of 0.9% normal saline. 3.6% by substituting Nor-epinephiine, 5.7% by substituting blood transfusion, and 7,2% by substituting Albumin were recovered. And the stronger the degree of symptoms observed in hypotention, the more the treatments required for recovery and these showed statistically significant differences (P=0.0000). C. On the effects of the changes of blood pressure and osmolality by albumin and hemofiltration. 1. Changes of blood pressure in the group which didn't required treatment in hypotension and the group required treatment, were averaged 21.5mmHg and 44.82mmHg. So the difference in the latter was bigger than the former and these showed statistically significant difference (P=0.002). On the changes of osmolality, average mean were 12.65mOsm, and 17.57mOsm. So the difference was bigger in the latter than in the former but these not showed statistically significance (P=0.323). 2. Changes of blood pressure in the group infused albumin and in the group didn't required treatment in hypotension, were averaged 30mmHg and 21.5mmHg. So there was no significant differences and it showed no statistical significance (P=0.503). Changes of osmolality were averaged 5.63mOsm and 12.65mOsm. So the difference was smaller in the former but these was no stitistical significance (P=0.287). Changes of blood pressure in the group infused Albumin and in the group required treatment in hypotension were averaged 30mmHg and 44.82mmHg. So the difference was smaller in the former but there is no significant difference (P=0.061). Changes of osmolality were averaged 8.63mOsm, and 17.59mOsm. So the difference were smaller in the former but these not showed statistically significance (P=0.093). 3. Changes of blood pressure in the group iutplemented hemofiltration and in the Uoup didn't required treatment in hypotension were averaged 22mmHg and 21.5mmHg. So there was no significant differences and also these showed no statistical significance (P=0.320). Changes of osmolality were averaged 0.4mOsm and 12.65mOsm. So the difference was smaller in the former but these not showed statistical significance(P=0.199). Changes of blood pressure in the group implemented hemofiltration and in the group required treatment in hypotension were averaged 22mmHg and 44.82mmHg. So the difference was smatter in the former and these showed statistically significant differences (P=0.035). Changes of osmolality were averaged 0.4mOsm and 17.59mOsm. So the difference was smaller in the former but these not showed statistical significance (P=0.086). D. On the changes of body weight, and blood pressure, between the group of hemofiltration and hemodialysis. 1, Changes of body weight in the group implemented hemofiltration and hemodialysis were averaged 3.340 and 3.320. So there was no significant differences and these showed no statistically significant difference, (P=0.185) but standard deviation of body weight averaged in comparison with standard difference of body weight was statistically significant difference (P=0.0000). Change of blood Pressure in the group implemented hemofiltration and hemodialysis were averaged 17.81mmHg and 19.47mmHg. So there was no significant differences and these showed no statistically significant difference (P=0.119), But in comparison with standard deviation about difference of blood pressure was statistically significant difference. (P=0.0000). E. On the blood infusion method in coil after hemodialysis and residual blood losing method in coil. 1, On comparing and analysing Hct of residual blood in coil by factors influencing blood infusion method. Infusion method of saline 200cc reduced residual blood in coil after the quantitative comparison of Saline Occ, 50cc, 100cc, 200cc and the differences showed statistical significance (p < 0.001). Shaking Coil method reduced residual blood in Coil in comparison of Shaking Coil method and Non-Shaking Coil method this showed statistically significant difference (P < 0.05). Adjusting pressure in Coil at OmmHg method reduced residual blood in Coil in comparison of adjusting pressure in Coil at OmmHg and 200mmHg, and this showed statistically significant difference (P < 0.001). 2. Comparing blood infusion method divided into 10 methods in Coil with every factor respectively, there was seldom difference in group of choosing Saline 100cc infusion between Coil at OmmHg. The measured quantity of blood loss was averaged 13.49cc. Shaking Coil method in case of choosing saline 50cc infusion while adjusting pressure in coil at OmmHg was the most effective to reduce residual blood. The measured quantity of blood loss was averaged 15.18cc.

  • PDF

A Clinical Study of Acute Poststreptococcal Glomerulonephritis with Nephrotic Syndrome (신증후군을 동반한 연쇄상구균 감염후 급성사구체신염의 임상적 고찰)

  • Moon Sang-Ae;Yook Jin-Won;Kim Ji-Hong;Lee Jae-Seung;Jeong Hyun-Joo;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.123-129
    • /
    • 1999
  • Purpose: Acute poststreptococcal glomerulonephritis(APSGN) is a renal disease which is characterized by glomerular proliferation and inflammatory changes due to immune reaction. Although the 95% of patients with APSGN seems to recover fully and present as benign course, the remaining patients show poor prognosis. Therefore comparative retrograde study between APSGN with and without nephrotic syndrome was done to find out the any prognostic indicator to predict the outcome in patients with APSGN. Methods: We had retrospectively analyzed seventy-one patients who were diagnosed as APSGN clinically from Mar.1989 to Feb.1999 in Yonsei university medical center. Sixty-four of the patients was APSGN without nephrotic syndrome(Group A) and seven patients were in APSGN with nephrotic syndrome(Group B). Results: Patients who were diagnosed as APSGN with nephrotic syndrome were seven(9.9%) out of seventy-one. In the comparative study, sex ratio was 1:1 in group A and 1.9: 1 in group B, onset mean age was $8.9{\pm}2.6$ in group A and $8.8{\pm}2.6$ in group B. Following clinical profiles were compared but there were no significant difference between these two groups: WBC count($9413{\pm}2964\;vs\;9368{\pm}2650(/mm^3)$), hemoglobin($10.6{\pm}1.2\;vs\;10.0{\pm}0.9(gm/dL)$), ASO($746.1{\pm}640.7\;vs\;614.9{\pm}475.9(IU/ml)$), $C_3(20.1{\pm}17.0\;vs\;16.9{\pm}13.1(mg/dL)$), $C_4(22.8{\pm}9.5\;vs\;22.6{\pm}6.9(mg/dL)$), BUN($25.8{\pm}26.1\;vs\;28.1{\pm}14.5(mg/dL)$), creatinin($0.8{\pm}0.3\;vs\;0.8{\pm}0.3(mg/dL)$), $C_{cr}(80.6{\pm}28.8{\pm}62.4{\pm}31.4(ml/min/1.73\;m^2$)), the duration of edma, gross hematuria, and hypertension. However, we found that there were a significant difference in the duration of proteinuria($1.95{\pm}2.27\;vs\;13.3{\pm}21.1(months)$)(P<0.05), decreased $C_3$ duration($1.9{\pm}2.9\;vs\;7.3{\pm}5.0(weeks)$)(P<0.05) and especially it was proloned according to the amount of early urine protein excretion. Conclusion: Our study showed markedly prolonged duration of proteinuria and decreased $C_3$ duration in patients with APSGN with nephrotic syndrome. We were not able to find the definite prognostic factor that will guide the outcome of patients with APSGN accompaning nephrotic syndrome, but above findings seemed to represent as a relative indication of the outcome of the disease. All patients recovered completely and we did not experience any cases that progressed into the renal failure.

  • PDF

Clinical Analysis of Children with Transitory Minimal Change Nephrotic Syndrome (MCNS) to Focal Segmental Glomerulosclerosis (FSCS) (미세변화형 신증후군(MCNS)으로부터 국소성 분절성 사구체 경화증(FSGS)으로 이행된 환아의 임상양상)

  • Lee Ji Eun;Yook Jinwon;Lee Eui Seong;Kim Ji Hong;Kim Pyung-Kil;Chung Hyun Joo
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 2000
  • Purpose: MCNS is found in approximately $85\%$ of the idiopathic nephrotic syndrome in children and shows good prognosis with initial steroid therapy. However in FSGS, there is poor prognosis with initial therapy and shows higher rate of progression to chronic renal failure and relapse after kindney transplantation. We have experienced 8 patients who were diagnosed as MCNS on initial renal biopsy and then progressed to FSGS on follow-up biopsy. So we have investigated their clinical course and risk factors for transition of MCNS to FSGS. Methods: We conducted a retrospective study with a review of histopathologic findings and clinical manifestations of 296 cases of MCNS and FSGS that were diagnosed from January 1988 to May 1999. We classified them into 3 groups according to the histopathologic finding; MCNS, FSGS, MCNS progressed to FSGS in follow-up biopsy. Results: The number of children was 296 cases comprising 241 cases($81.4\%$) showing MCNS, 8 cases($2.7\%$) transition group, 47 cases($15.9\%$) FSGS. The mean onset age was $6.0{\pm}2.6$years in MCNS, transition group $8.3{\pm}2.3$years, FSGS $7.2{\pm4.3$years, and the gender (M:F) ratio was 3.7:1 in MCNS, 3:1 in transition group, 1.8:1 in FSGS. Comparing the presence of initial hematuria, hypertension,24 hour urine protein, serum albumin, serum creatinine, there were significant difference between the transition group and the FSGS group in the following points; 24hour urine protein $684:342mg/m^2/hr$(P<0.05), serum albumin 1.92: 2.47g/dL(P<0.05), serum cholesterol 494:343mg/dL(P<0.05). Refractoriness to steroid therapy was 13.3$\%$ in MCNS. $12.5\%$ in transition group, $29.6\%$ in FSGS; significantly higher in FSGS(P<0.05). Immunosuppressant therapy was performed in $58.5\%$ of MCNS, $100\%$ in transition group, $80.8\%$ in FSGS; transition group showed significantly higher .ate(P<0.05) comparing with MCNS. Mean number of relapse and duration from onset to first relapse showed no significance difference between these groups. Conclusion: 249 patients with MCNS have been followed and $3.2\%$ (8 patients) of them has shown change in pathologic diagnosis from MCNS to FSCS. The risk factor for transition could not be found. Our results point to the need for a follow-up biopsy to certify the possibility of transition to FSCS in some MCNS cases with refractory cases to steroid therepy, frequent relapsing cases, or in case of no remission in spite of vigorous immunosuppressant therapy.

  • PDF

The Etiologies and Initial Antimicrobial Therapy Outcomes in One Tertiary Hospital ICU-admitted Patient with Severe Community-acquired Pneumonia (국내 한 3차 병원 중환자실에 입원한 중증지역획득폐렴 환자의 원인 미생물과 경험적 항균제 치료 성적의 고찰)

  • Lee, Jae Seung;Chung, Joo Won;Koh, Yunsuck;Lim, Chae-Man;Jung, Young Joo;Oh, Youn Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.522-529
    • /
    • 2005
  • Background : Several national societies have published guidelines for empirical antimicrobial therapy in patients with severe community-acquired pneumonia (SCAP). This study investigated the etiologies of SCAP in the Asan Medical Center and assessed the relationship between the initial empirical antimicrobial regimen and 30 day mortality rate. Method : retrospective analysis was performed on patients with SCAP admitted to the ICU between March 2002 and February 2004 in the Asan Medical Center. The basic demographic data, bacteriologic study results and initial antimicrobial regimen were examined for all patients. The clinical outcomes including the ICU length of stay, the ICU mortality rate, and 30 days mortality rates were assessed by the initial antimicrobial regimen. Results : One hundred sixteen consecutive patients were admitted to the ICU (mean age 66.5 years, 81.9 % male, 30 days mortality 28.4 %). The microbiologic diagnosis was established in 58 patients (50 %). The most common pathogens were S. pneumoniae (n=12), P. aeruginosae (n=9), K. pneumonia (n=9) and S. aureus (n=8). The initial empirical antimicrobial regimens were classified as: ${\beta}$-lactam plus macrolide; ${\beta}$-lactam plus fluoroquinolone; anti-Pseudomonal ${\beta}$-lactam plus fluoroquinolone; Aminoglycoside combination regimen; ${\beta}$-lactam plus clindamycin; and ${\beta}$-lactam alone. There were no statistical significant differences in the 30-day mortality rate according to the initial antimicrobial regimen (p = 0.682). Multivariate analysis revealed that acute renal failure, acute respiratory distress syndrome and K. pneumonae were independent risk factors related to the 30 day mortality rate. Conclusion : S. pneumoniae, P. aeruginosae, K. pneumonia and S. aureus were the most common causative pathogens in patients with SCAP and K. pneumoniae was an independent risk factor for 30 day mortality. The initial antimicrobial regimen was not associated with the 30-day mortality.

Factors Related with the Compliance and Treatment in Patients with Pulmonary Tuberculosis in Urban and Suburb Area (도시와 농촌지역의 폐결핵 환자 순응도 및 치료에 관련된 요인)

  • Kim, Sang-Soon;Kim, Yoon-Ock
    • Research in Community and Public Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.69-79
    • /
    • 1996
  • To investigate the factors related with the compliance and the treatment of the patients with pulmonary tuberculosis in urban and suburb area, we followed up all the 755 registered patients(at urban Public Health Office 544, at suburb 210) as follow from January 1,1992 to December 31, 1993. We describe the general characteristics and the characteristics related with the disease of the patients according to the area as follow. 150 patients(27.5%) were at their age of 20 to 29 years in the urban area, whereas 45 patients (21.4%) were 60 to 69 years and another 45 patients(21.4%) were 70 to 79 years in the suburb area. According to the first chest X -ray examination, 54.5% of all cases were proved to be mild in the urban area. But in the suburb area, moderate cases (44.3%) were more than mild cases(p<0.01). Follow-up X-ray's were performed more properly(p<0.05) in the urban area(94.3%) than in the suburb area(90.0%). Most cases were found in the chest X -ray examination performed by Public Health Office (p<0.01) : payable chest X-ray in the urban area (56.7%) and free chest X-ray in the suburb area(35.2%). More patients were cured in the urban area(90.8%) than in the suburb area(87.1%). The presence of supporting family member were significantly higher(p<0.05) in the urban area(79.1%) than in the suburb area(88.1%). In the analysis of the treatment efficacy, more cure ate were found in the patients cytologically confirmed to be culture (+). In the urban area, 201 culture (+) patients (93.5%) 294 culture (-) patients (89.1%) were cured. In the suburb area, 99 culture (+) patients(91.7%) and 84 culture (-) patients(82.4%) were cured. Age, the presence of supporting family member, and the socioeconomic status of the patient had significant association with the prescription compliance related with the general characteristics of the patients. Whereas, X-ray finding and AFB culture finding were the significant factors associated with the prescription compliance related with pulmonary tuberculosis (p<0.05). The cumulative compliance in the survival analysis was 92.5% in the urban area and 88.1% in suburb area, at sixth month of follow-up. Failure rate for regular drug receipt was highest at second month in the urban area(3.75%) and at fourth month in the suburb area(4.15%). In logistic regression of the factors related with the tratment result, first X-ray examination and prescription compliance were significantly associated in the urban area(p<0.05). However, there is no factor significantly associated with the treatment result in the suburb area. It could be explained by too small size of the sample. In logistic regression of the factors related with the prescription compliance, first chest X-ray, sputum culture outcome and the presence of supporting family member were significant variables in the urban area(p<0.05). Most patients with family member were proved to be compliant with the prescription. This shows that it is important for the patients with long-lasting ilnesses to have supporting family member. Therefore, to improve prescription compliance we should strengthen the health education before the initiation of treatment and take special interest in the patients without supporting family member.

  • PDF

The Results and Prognostic Factors of Chemo-radiation Therapy in the Management of Small Cell Lung Cancer (항암화학요법과 방사선 치료를 시행한 소세포폐암 환자의 치료 성적 -생존율과 예후인자, 실패양상-)

  • Kim Eun-Seog;Choi Doo-Ho;Won Jong-Ho;Uh Soo-Taek;Hong Dae-Sik;Park Choon-Sik;Park Hee-Sook;Youm Wook
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.433-440
    • /
    • 1998
  • Purpose : Although small ceil lung cancer (SCLC) has high response rate to chemotherapy and radiotherapy (RT), the prognosis is dismal. The authors evaluated survival and failure patterns according to the prognostic factors in SCLC patients who had thoracic radiation therapy with chemotherapy. Materials and Methods : One hundred and twenty nine patients with SCLC had received thoracic radiation therapy from August 1985 to December 1990. Seventy-seven accessible patients were evaluated retrospectively among 87 patients who completed RT. Median follow-up period was 14 months (2-87months). Results : The two years survival rate was 13$\%$ with a median survival time of 14 months. The two year survival rates of limited disease and extensive disease were 20$\%$ and 8$\%$, respectively, with median survival time of 14 months and 9 months, respectively. Twenty two patients (88$\%$) of limited disease showed complete response (CR) and 3 patients (12$\%$) did partial response (PR). The two year survival rates on CR and PR groups were 24$\%$ and 0$\%$, with median survival times of 14 months and 5 months. respectively (p=0.005). No patients with serum sodium were lower than 135 mmol/L survived 2years and their median survival time was 7 months (p=0.002). Patients whose alkaline phophatase lower than 130 IU/L showed 26$\%$ of 2 year survival rate and showed median survival time of 14 months and those with alkaline phosphatase higher than 130 IU/L showed no 2 year survival and median survival time of 5 the months, respectively (p=0.019). No statistical differences were found according to the age, sex, and performance status. Among the patients with extensive disease, two rear survivals according to the metastatic sites were 14$\%$, 0$\%$, and 7$\%$ in brain, liver, and other metastatic sites, respectively, with median survival time of 9 months, 9 months, and 8 months, respectively (p>0.05). Two year survivals on CR group and PR group were 15$\%$ and 4$\%$, respectively, with a median survival time of 11 months and 7 months, respectively (p=0.01). Conclusion : For SCLC, complete response after chemoradiotherapy was the most significant prognostic tactor. To achieve this goal. there should be further investigation about hyperfractionation, dose escalation, and compatible chemo-radiation schedule such as concurrent chemo-radiation and early radiation therapy with chemotherapy.

  • PDF

Construction and Application of Intelligent Decision Support System through Defense Ontology - Application example of Air Force Logistics Situation Management System (국방 온톨로지를 통한 지능형 의사결정지원시스템 구축 및 활용 - 공군 군수상황관리체계 적용 사례)

  • Jo, Wongi;Kim, Hak-Jin
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.2
    • /
    • pp.77-97
    • /
    • 2019
  • The large amount of data that emerges from the initial connection environment of the Fourth Industrial Revolution is a major factor that distinguishes the Fourth Industrial Revolution from the existing production environment. This environment has two-sided features that allow it to produce data while using it. And the data produced so produces another value. Due to the massive scale of data, future information systems need to process more data in terms of quantities than existing information systems. In addition, in terms of quality, only a large amount of data, Ability is required. In a small-scale information system, it is possible for a person to accurately understand the system and obtain the necessary information, but in a variety of complex systems where it is difficult to understand the system accurately, it becomes increasingly difficult to acquire the desired information. In other words, more accurate processing of large amounts of data has become a basic condition for future information systems. This problem related to the efficient performance of the information system can be solved by building a semantic web which enables various information processing by expressing the collected data as an ontology that can be understood by not only people but also computers. For example, as in most other organizations, IT has been introduced in the military, and most of the work has been done through information systems. Currently, most of the work is done through information systems. As existing systems contain increasingly large amounts of data, efforts are needed to make the system easier to use through its data utilization. An ontology-based system has a large data semantic network through connection with other systems, and has a wide range of databases that can be utilized, and has the advantage of searching more precisely and quickly through relationships between predefined concepts. In this paper, we propose a defense ontology as a method for effective data management and decision support. In order to judge the applicability and effectiveness of the actual system, we reconstructed the existing air force munitions situation management system as an ontology based system. It is a system constructed to strengthen management and control of logistics situation of commanders and practitioners by providing real - time information on maintenance and distribution situation as it becomes difficult to use complicated logistics information system with large amount of data. Although it is a method to take pre-specified necessary information from the existing logistics system and display it as a web page, it is also difficult to confirm this system except for a few specified items in advance, and it is also time-consuming to extend the additional function if necessary And it is a system composed of category type without search function. Therefore, it has a disadvantage that it can be easily utilized only when the system is well known as in the existing system. The ontology-based logistics situation management system is designed to provide the intuitive visualization of the complex information of the existing logistics information system through the ontology. In order to construct the logistics situation management system through the ontology, And the useful functions such as performance - based logistics support contract management and component dictionary are further identified and included in the ontology. In order to confirm whether the constructed ontology can be used for decision support, it is necessary to implement a meaningful analysis function such as calculation of the utilization rate of the aircraft, inquiry about performance-based military contract. Especially, in contrast to building ontology database in ontology study in the past, in this study, time series data which change value according to time such as the state of aircraft by date are constructed by ontology, and through the constructed ontology, It is confirmed that it is possible to calculate the utilization rate based on various criteria as well as the computable utilization rate. In addition, the data related to performance-based logistics contracts introduced as a new maintenance method of aircraft and other munitions can be inquired into various contents, and it is easy to calculate performance indexes used in performance-based logistics contract through reasoning and functions. Of course, we propose a new performance index that complements the limitations of the currently applied performance indicators, and calculate it through the ontology, confirming the possibility of using the constructed ontology. Finally, it is possible to calculate the failure rate or reliability of each component, including MTBF data of the selected fault-tolerant item based on the actual part consumption performance. The reliability of the mission and the reliability of the system are calculated. In order to confirm the usability of the constructed ontology-based logistics situation management system, the proposed system through the Technology Acceptance Model (TAM), which is a representative model for measuring the acceptability of the technology, is more useful and convenient than the existing system.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF