• Title/Summary/Keyword: Failure Rate Model

Search Result 638, Processing Time 0.029 seconds

Optimal Design of Mobile Controlled Location Update Subsystem

  • Kang, Hye-Won;Park, Cheon-Won
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.25-28
    • /
    • 1999
  • Consider connection-oriented wireless cellular net-works. To establish a circuit or virtual circuit in such a network, a paging message is broadcast over a region at which the destined mobile station is presumed to reside, (identified as a paging area). For an effective paging mechanism, it is desirable to provide the location information of mobile stations to the network. In this paper, we consider a mobile controlled location update scheme under which each mobile station periodically reports its current location information to the network by using an inherent timer (without measuring the power of signals transmitted from base stations). Based on the latest information about a mobile station's location, a paging area is selected to page the mobile station. Note that under this scheme, a mobile station may not yet have reported its location change while sojourning out of the current paging area. In such situation, the mobile station can not receive a paging message destined to it. Frequent location updates can reduce the paging failure rate incurred by mobile stations'sojourning out of the paging area. However, larger bandwidth is needed for location update as the location update rate is increased. On the other hand, as the size of the paging area is increased, the paging failure rate is decreased, while larger bandwidth is required for paging. Thus, we first present a model for mobility, paging and location update processes, and secondly investigate the effect of network parameters on the paging failure rate and the amount of bandwidth used for paging and location update. Finally, we formulate problems to find proper values for the location update rate and paging area size under the constraints on the bandwidth usage levels for location update and paging.

  • PDF

Fracture Analysis Considering the Non-uniform Corrosion Distribution (비선형 부식분포를 고려한 철근덮개 파괴해석)

  • 오병환;장봉석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1041-1044
    • /
    • 2001
  • This study was performed to evaluate the effect of non-uniform corrosion distribution on the analysis of concrete cover failure. A series of experiments have been undertaken to measure the corrosion rate of reinforcement according to the concentration of chloride ion so as to suggest a relationship between the reinforcement corrosion rate and chloride ion density. The corrosion induced pressure depending on the density of chloride ion has been derived. And nonlinear analysis assuming nonlinear corrosion distribution for cover cracking was achieved and compared with other experimental results to verify the accuracy of the model. Analysis was also performed for various parameters to compare their effects.

  • PDF

Reliability Evaluation of a Microgrid Considering Its Operating Condition

  • Xu, Xufeng;Mitra, Joydeep;Wang, Tingting;Mu, Longhua
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.47-54
    • /
    • 2016
  • Microgrids offer several reliability benefits, such as the improvement of load-point reliability and the opportunity for reliability-differentiated services. The primary goal of this work is to investigate the impacts of operating condition on the reliability index for microgrid system. It relies on a component failure rate model which quantifies the relationship between component failure rate and state variables. Some parameters involved are characterized by subjective uncertainty. Thus, fuzzy numbers are introduced to represent such parameters, and an optimization model based on Fuzzy Chance Constrained Programming (FCCP) is established for reliability index calculation. In addition, we present a hybrid algorithm which combines scenario enumeration and fuzzy simulation as a solution tool. The simulations in a microgrid test system show that reliability indices without considering operating condition can often prove to be optimistic. We also investigate two groups of situations, which include the different penetration levels of microsource and different confidence levels. The results support the necessity of considering operating condition for achieving accurate reliability evaluation.

Determination of optimal maintenance interval at power distribution system equipment using a Markov Model (Markov Model을 이용한 배전계통 기기의 유지보수 최적주기 결정)

  • Park, Geun-Pyo;Moon, Jong-Fil;Yoon, Yong-Tae;Lee, Sang-Seung;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.249-251
    • /
    • 2005
  • 전력 산업구조개편으로 인하여 전력회사의 민영화가 진행됨에 따라 전력회사에서는 한정된 예산으로 배전계통을 운영함으로써 유지보수를 위한 충분한 여유가 없어지게 될 것이다. 이러한 환경에서 한정된 비용으로 계통의 신뢰도를 일정 수준 이상으로 유지해야만 하는 문제에 직면하게 되며, 이는 매우 어려운 일이다. 이를 위해서는 최소의 비용으로 최대의 유지보수 효과를 낼 수 있는 방법을 개발해야 하며, 최적의 유지보수 주기를 찾는 것이 중요한 문제라 할 수 있다. 본 논문에서는 이런 문제론 해결하기 위해, 유지보수 기기 선정 및 유지보수 주기를 결정하는데 있어 검증된 기법인 Reliability Centered Maintenance (RCM) 기법을 이용하였다. 배전계통 기기의 유지보수에 있어서 Four-state Markov 모델을 이용하여 기기의 유지보수에 드는 비용과 기기의 고장에 의한 정전비용 사이의 trade-off를 고려하여 총 비용이 최소가 되는 최적의 유지보수 주기를 찾고자 한다. 이를 위하여 기존의 모델에서 평균고장률(mean failure rate)을 사용한 것과는 달리 시변 고장률(time-varying failure rate)을 적용하였으며, 또한 유지보수에 따른 고장률의 감소도 고려함으로써 최적의 유지보수 주기를 결정할 수 있었다.

  • PDF

A study on the economical life of large-diameter water pipe: case study in P waterworks (대구경 상수도관로의 경제적수명 산정 연구: P상수도 사례연구)

  • Kim, Kibum;Seo, Jeewon;Choi, Taeho;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2018
  • This study develops a model to estimate the economic life of the large-diameter water supply pipeline in Korea by supplementing existing methods used to perform similar calculations. To evaluate the developed methodology, the model was applied to the actual target area with the conveyance pipe in P waterworks. The application yielded an economic life computation of 39.7 years, considering the cost of damages, maintenance, and renewal of the pipeline. Based on a sensitivity analysis of the derived results, the most important factor influencing the economic life expectancy was the predicted failure rate. The methodology for estimating the economic life of the water supply pipeline proposed in this study is one of the core processes of basic waterworks facility management planning. Therefore, the methods and results proposed in this study may be applied to asset management planning for water service providers.

Recommendation of I-D Criterion for Steep-Slope Failure Estimation Considering Rainfall Infiltration Mechanism (강우침투 메커니즘을 이용한 급경사지 붕괴예측 I-D 기준식 제안)

  • Song, Young-Karb;Kim, Young-Uk;Kim, Dong-Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.65-74
    • /
    • 2013
  • The natural disaster occurrences and the loss of lives caused by the steep-slope failures in Korea were investigated in this study. The investigation includes the frequency rate of the steep-slope failures with respect to the characteristics of precipitation, underlying bedrock, and weathered soils. Analysis on the problems in the existing estimation methods of steep-slope failure was also undertaken, and a new model using unsaturated infinite slope stability was developed for the better slope failure estimation. The slope analyses by the newly developed model were performed considering unsaturated infinite slope, the gradient of slope, and hydro/mechanical properties of soils. Steep-slope failure estimation criterion is proposed based on the analysis results. In addition, the precipitation amount corresponding to warning stages against steep-slope failure is provided as an equation of Intensity-Duration criterion.

Physical test and PFC2D simulation of the failure mechanism of echelon joint under uniaxial compression

  • Sarfarazi, V.;Abharian, S.;Ghalam, E. Zarrin
    • Computers and Concrete
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2021
  • Experimental and discrete element methods were used to investigate the effects of echelon non-persistent joint on the failure behaviour of joint's bridge area under uniaxial compressive test. Concrete samples with dimension of 150 mm×100 mm×50 mm were prepared. Uniaxial compressive strength and tensile strength of concrete were 14 MPa and 1MPa, respectivly. Within the specimen, three echelon non-persistent notches were provided. These joints were distributed on the three diagonal plane. the angle of diagonal plane related to horizontal axis were 15°, 30° and 45°. The angle of joints related to diagonal plane were 30°, 45°, 60°. Totally, 9 different configuration systems were prepared for non-persistent joint. In these configurations, the length of joints were taken as 2 cm. Similar to those for joints configuration systems in the experimental tests, 9 models with different echelon non-persistent joint were prepared in numerical model. The axial load was applied to the model by rate of 0.05 mm/min. the results show that the failure process was mostly governed by both of the non-persistent joint angle and diagonal plane angle. The compressive strengths of the specimens were related to the fracture pattern and failure mechanism of the discontinuities. It was shown that the shear behaviour of discontinuities is related to the number of the induced tensile cracks which are increased by increasing the joint angle. The strength of samples increase by increasing both of the joint angle and diagonal plane angle. The failure pattern and failure strength are similar in both methods i.e. the experimental testing and the numerical simulation methods.

Interaction between opening space in concrete slab and non-persistent joint under uniaxial compression using experimental test and numerical simulation

  • Vahab Sarfarazi;Kaveh Asgari;Mehdi Kargozari;Pouyan Ebneabbasi
    • Computers and Concrete
    • /
    • v.31 no.3
    • /
    • pp.207-221
    • /
    • 2023
  • In this investigation, the interaction between opening space and neighboring joint has been examined by experimental test and Particle flow code in two dimension (PFC2D) simulation. Since, firs of all PFC was calibrated using Brazilian experimental test and uniaxial compression test. Secondly, diverse configurations of opening and neighboring joint were provided and tested by uniaxial test. 12 rectangular sample with dimension of 10 cm*10 cm was prepared from gypsum mixture. One quarter of tunnel and one and or two joint were drilled into the sample. Tunnel diameter was 5.5 cm. The angularities of joint in physical test were 0°, 45° and 90°. The angularities of joint in numerical simulation were 0°, 30°, 60°, -30°, -45°, -60° and its length were 2cm and 4cm. Loading rate was 0.016 m/s. Tensile strength of material was 4.5 MPa. Results shows that dominant type of crack which took place in the model was tensile cracks and or several shear bands develop within the model. The Final stress is minimum in the cases where oriented angle is negative. The failure stress decrease by decreasing the joint angle from 30° to 60°. In addition, the failure stress decrease by incrementing the joint angle from -30° to -60°. The failure stress was incremented by decreasing the number of notches. The failure stress was incremented by decreasing the joint length. The failure stress was incremented by decreasing the number of notches. Comparing experimental results and numerical one, showed that the failure stress is approximately identical in both conditions.

Study on a Optimal Inspection Cycle of Electrical facility of Railroad (철도전기설비의 최적점검주기에 관한 기초연구)

  • Chu, Cheol-Min;Kim, Jae-Chul;Lee, Tae-Hee;An, Jae-Min;Moon, Jong-Fil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.224-228
    • /
    • 2007
  • It is focused on a methodology to establish a optimal inspection cycle of electrical facility of railroad Decision method of optimal inspection cycle is a process which establishes maintenance plan for facilities' immanent function as using reliability theory in operation term In order to ensure normal operation in a given condition, the decision method is logical for selecting effective maintenance plan to consider characteristic of system In estimation of failure rate, critical facility is selected firstly. After that, proper distribution function on each facility is decided to investigate distribution function for extraction of failure rate. Next, cost produced by the case that facility's failure is occurred is surveyed. Finally, maintenance method developed until now is investigated, before suitable model for the facility applying maintenance method is developed, and that maintenance decision is made. Therefore, this process is the method to find optimal inspection cycle for reasonable cost and effective reliability on facility.

  • PDF

Color coding of MF(model failure) object using hybrid coding method in object based coding (객체기반 부호화에서 혼합형 부호화방식을 이용한 MF(Model Failure) 객체의 색신호 부호화)

  • 김동하;이지훈;고성제;이태원
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.5
    • /
    • pp.45-51
    • /
    • 1997
  • To trnsmit moving image signals by using an object vased coding technique at the rate of 8kbps~11kbps, it is very important to minimize the bit rates used for the compression of the color information of MF-objects. This paper proposes a hybrid coding method which uses the shpae adaptive coding method and the interframe reference method selectively. Gilge's shape adaptive orthogonal coidng method is utilized for shpae adaptive coding. The interfarame reference method approximates the low-passed signals of the image by gilge's shpae adaptive orthogonalization method and then refers the approximation error signals from the high frequency signal components of th eprevious frame. The proposed method achives the bit rates reduction of 17% compared to the gilge's shape adaptive orthogonalization method and 30% rduction compared to the shape adaptive DCT in average.

  • PDF