• Title/Summary/Keyword: Failure Index

Search Result 811, Processing Time 0.026 seconds

Impact of hidden failure analysis of protective relay in transmission system (송전계통 보호계전기 취약도 평가)

  • Jin, Bo-Gun;Lee, Seung-Jae;Kim, S.-Tae;Lee, Dong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.12-14
    • /
    • 2006
  • This paper presents an vulnerability index for hidden failure of protective relays in transmission system. The bad influence can be quantized by an vulnerability index. When there is mis-operation, no-operation or mis-setting, power flow can be quantized by an index. According to the index, relays can be resetting. So the wide area blackout can be prevented.

  • PDF

Safety Evaluation of Carbon Fiber/Epoxy Composite Link Using Micromechanics of Failure Criterion (미시역학적 파손 기준을 이용한 탄소섬유/에폭시 복합재 링크의 안전성 평가)

  • Jae Ho Cha;Sung Ho Yoon
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.154-161
    • /
    • 2023
  • This study explored the feasibility of replacing a metal link with a carbon fiber/epoxy composite link and assessed its capacity to withstand a given load condition using failure criteria. The micromechanics of failure (MMF) criterion was employed to predict the failure mode of the composite material, and mechanical tests were conducted to obtain reference strength parameters for MMF. The findings revealed that the stress distribution was concentrated near the hole, and weaknesses were found around the hole and at the end of the link under bending conditions. Based on the failure index, matrix tensile failure was predicted at the end of the link, and fiber compression failure occurred near the hole. The methods and results obtained from this study can provide valuable guidelines for assessing the safety of composite materials under specific load conditions when replacing metal parts with carbon fiber/epoxy composites to achieve weight reduction.

A Study on Design Criteria of Rockfall Protection Fence Considering Reliability Index (신뢰성지수를 고려한 낙석방지울타리 설계기준 고찰)

  • Suk, JaeWook;Lee, JongGun;Kim, YongSoo;Moon, JoonShik
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.275-281
    • /
    • 2014
  • The performance criteria of rockfall protection fence and reliability index were investigated considering characteristic of rockfall energy occurred at 160 cut slopes in national highway. As a result of study on statistic of variables that decide rockfall energy using Monte-Carlo simulation, the degree of slope was normal distribution type, mass of rockfall and height of slope was lognormal distribution type. The rockfall energy follows lognormal distribution because of statistical characteristic of mass of rockfall. The reliability index of rockfall protection fence was 0.678 and the failure probability of was very high as 24.9%. Proposed performance criteria of rockfall protection fence considering the scale of domestic rockfall energy is maximum 500 kJ and the range of reliability index was from 1.028 to 1.956. the failure probability of rockfall protection fence was from 14.8 to 2.5 percent if applying the performance criteria using the reliability index.

The T-tree index recovery for distributed main-memory database systems in ATM switching systems (ATM 교환기용 분산 주기억장치 상주 데이터베이스 시스템에서의 T-tree 색인 구조의 회복 기법)

  • 이승선;조완섭;윤용익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1867-1879
    • /
    • 1997
  • DREAM-S is a distributed main-memory database system for the real-time processing of shared operational datra in ATM switching systems. DREAM-S has a client-server architecture in which only the server has the diskstorage, and provides the T-Tree index structure for efficient accesses to the data. We propose a recovery technique for the T-Tree index structre in DREAM-S. Although main-memory database system offer efficient access performance, the database int he main-memory may be broken when system failure such as database transaction failure or power failure occurs. Therfore, a recovery technique that recovers the database (including index structures) is essential for fault tolerant ATM switching systems. Proposed recovery technique relieves the bottleneck of the server processors disk operations by maintaining the T-Tree index structure only in the main-memory. In addition, fast recovery is guaranteed even in large number of client systems since the T-Tree index structure(s) in each system can be recovered cncurrently.

  • PDF

Pharmacokinetics of Propranolol in Rabbits with Hepatic Failure (간장 장해 가토에서 푸로푸라놀롤의 체내 동태)

  • Lee, Jin-Hwan;An, Seon-Yeob
    • Journal of Pharmaceutical Investigation
    • /
    • v.20 no.4
    • /
    • pp.199-203
    • /
    • 1990
  • The pharmacokinetics of propranolol administered orally (10 me/kg) was investgated in the rabbits of carbon tetrachloride induced hepatic failure. The plasma concentration and relative bioavailability of propranolol were increased significantly in hepatic failure rabbits, compared with those of normal rabbits. There were significant relationship between GOT, GPT value and bioavailability parameters of propranolol. In short, dosage regimen of propranolol is considered to be adjusted in dose size and dosing interval using GOT or GPT an index.

  • PDF

Implementation and assessment of advanced failure criteria for composite layered structures in FEMAP

  • Grasso, Amedeo;Nali, Pietro;Cinefra, Maria
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.1
    • /
    • pp.51-67
    • /
    • 2019
  • AMOSC (Automatic Margin Of Safety Calculation) is a SW tool which has been developed to calculate the failure index of layered composite structures by referring to the cutting edge state-of-the-art LaRC05 criterion. The stress field is calculated by a finite element code. AMOSC allows the user to calculate the failure index also by referring to the classical Hoffman criterion (which is commonly applied in the aerospace industry). When developing the code, particular care was devoted to the computational efficiency of the code and to the automatic reporting capability. The tool implemented is an API which has been embedded into Femap Siemens SW custom tools. Then, a user friendly graphical interface has been associated to the API. A number of study-cases have been solved to validate the code and they are illustrated through this work. Moreover, for the same structure, the differences in results produced by passing from Hoffman to LaRC05 criterion have been identified and discussed. A number of additional comparisons have thus been produced between the results obtained by applying the above two criteria. Possible future developments could explore the sensitivity of the failure indexes to a more accurate stress field inputs (e.g. by employing finite elements formulated on the basis of higher order/hierarchical kinematic theories).

Failure Strength of the Composite Mechanical Joint according to the Stacking Angle (적층각 변화에 따른 복합재료 기계적 체결부의 파손강도)

  • Jo, Dae-Hyeon;Kim, Cheol-Hwan;Choi, Jin-Ho
    • Composites Research
    • /
    • v.30 no.4
    • /
    • pp.229-234
    • /
    • 2017
  • Generally, joints are the weakest part in the composite structures. Composite joints can be classified into adhesive joints and mechanical joints, and mechanical joints are mainly used in areas less sensitive to environmental conditions. In this paper, the failure loads of composite mechanical joints with five different stacking angles are tested and predicted. Finite element analysis of mechanical joints were performed and failure loads were predicted by the FAI(Failure Area Index) method using Tsai-Wu and Yamada-Sun failure criteria, and the predicted failure loads were compared with experimental results. From the experiment and analysis, the failure loads of the mechanical joints were decreased as the ratio of 0 degree layer was low and they could be predicted within 13.03% using the FAI method and Yamada-Sun failure criteria.

Slope Failure Index System Based on the Behavior Characteristics : SFi-system (거동 특성에 따른 사면 파괴 지수 시스템 : SFi-system)

  • 윤운상;정의진;최재원;김정환;김원영;김춘식
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.23-37
    • /
    • 2002
  • Failure of the cut slope is triggered by combination of internal and extemal failure factors. Internal failure factors are related to geological and geometrical conditions of slope itself, and natural and/or artificial loadings on slope can be the external failure factors. Influences of these failure factors show different intensity according to the ground condition and are controlled by behavior characters of the slope. In this study, the soil depth ratio(SR), block size ratio(BR) and rock strength are used as the criteria to divide ground condition based on behavior characteristics. Ground condition of the slope is divided into discontinuous jointed rock mass and continuos soil-like mass, highly fractured rock mass and massive rock mass by the criteria(SR and BR). The SFi-system is a rating system to determine the slope failure index(SFi) by analyzing internal and external factors based on classification of the ground condition. The results of the SFi-system application to the real cut slopes show close relationship between the SFi value and potential or dimension of the failure. Therefore, the SFi-system can be used as a useful tool to predict and analyze the characteristic of the slope failure.

Factors Affecting Adherence to Self-care Behaviors among Outpatients with Heart Failure in Korea

  • Ok, Jong Sun;Choi, Heejung
    • Korean Journal of Adult Nursing
    • /
    • v.27 no.2
    • /
    • pp.242-250
    • /
    • 2015
  • Purpose: To evaluate heart failure knowledge and adherence to self-care behaviors, and to identify factors affecting adherence to self-care behaviors among Korean patients with heart failure. Methods: Correlational research using the European Heart Failure Self-care Behavior Scale, the Duke Activity Status Index, the Dutch Heart Failure Knowledge Scale, the New York Heart Association Functional Classification, and the Medical Outcomes Study Social Support Survey was conducted. A total of 280 outpatients with heart failure responded to the five questionnaires. Results: The mean scores for self-care adherence and heart failure knowledge were $31.98{\pm}6.81$ and $8.78{\pm}2.53$, respectively, indicating lower adherence and knowledge than those previously reported. Subjects with lower functional status, more social supports, and greater knowledge of heart failure are more likely to adhere to prescribed regimens. Conclusion: Nurses should focus on patient education and support to improve their adherence to self-care behaviors.

A Proposal for Damage Index of Steel Members under Cyclic Loading (반복하중하에서의 강부재에 대한 손상지수 제안)

  • Park, Yeon Soo;Kang, Dae Hung;Oh, Jung Tae;Choi, Dong Ho;Oh, Back Man
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.613-625
    • /
    • 2002
  • This paper aimed to investigate the damage process of steel parts experiencing failure under strong repeated loading. Likewise, a damage index using various factors related to the damage was proposed. An analysis method for evaluating the damage state was also developed. The damage assessment method focused on the local strain history at the cross-section of the heaviest concentration of deformation. Cantilever-type steel parts were analyzed under uniaxial load combined with a constant axial load, considering horizontal displacement history, Loading patterns and steel types were considered as the main parameters in analyzing the models. The effects of the parameters on the failure modes, deformation capacity, and damage process as seen from the analysis results were also discussed. Each failure process was compared as steel types. In addition, the failure of steel parts under strong repeated loading was determined according to loading. Results revealed that the state of the failure is closely related to the local plastic strain.