• 제목/요약/키워드: Factory noise

검색결과 94건 처리시간 0.028초

CAN기반 시스템의 통신 신뢰성 검증 (A Study on CAN Based System Reliability Test)

  • 김종현;정기현;최경희
    • 정보처리학회논문지C
    • /
    • 제15C권3호
    • /
    • pp.199-204
    • /
    • 2008
  • CAN은 처음에는 차량 네트워크에서의 사용을 위해 고안되었으나 잡음에 강하고 신뢰성이 높아 공장자동화 등에서도 많이 사용되고 있다. 그러나 1:1통신에서 네트워크 기반의 통신방식으로 변화되면서 각 장치의 기계적인 동작뿐만 아니라 전자, 소프트웨어적인 동작에 대해서도 철저한 검증이 필요하게 되었다. 본 논문은 CAN 기반 시스템에서 통신의 신뢰성을 데이터의 정확성에 대한 부분과 시간상의 정확성에 대한 부분을 검증하는 방법을 제시하고 있다.

준 경험기법을 이용한 고집적 반도체공장의 미진동 제어를 위한 구조물의 동적설계에 관한 연구 (A Study on the Structural Dynamic Design for Sub-micro Vibration Control in High Class Semiconductor Factor by Semi-Empirical Method)

  • 이홍기;백재호;원영재;박해동;김두훈
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1227-1233
    • /
    • 1999
  • Modern technology depends on the reliability of extremely high technology equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a nanometer. This equipment requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga and tera class semiconductor wafers. This high technology equipments require very strict environmental vibration standard, vibration criteria, in proportion to the accuracy of the manufacturing, inspecting devices. This paper deals with the structural dynamic design in high class semiconductor factory in order to be satisfied more strict vibration criteria for high sensitive equipment.

  • PDF

도시철도 표준전동차용 견인전동기의 국산화 설계 및 제작 (Standardization Design & Manufacturing of Traction Motor for Urban Transit EMU)

  • 왕종배;이수길;박현준;하현성;허익구;이인우;박창순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.424-426
    • /
    • 1999
  • In this paper, the design characteristics, the manufacturing process and the results of performance test on the AC traction motor for urban transit standard E.M.U which is newly developed with applying standardization specification will be introduced. It is reviewed that the design and performance analysis on conventional motors considering system correlation and design constraint and the design optimization through an analysis of electro-magnetic, thermal and dynamic properties. The properties of factory products manufactured by 200 Class VPI process exhibit a excellent performance with a lower noise and vibration, higher efficiency and power factor etc.

  • PDF

A Vision System for Detecting Paint Faults on Painted Slates

  • Shinji, Ohyama;Hong, Keum-Shik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.35.2-35
    • /
    • 2001
  • This paper is concerned with the problem of how to detect paint type defects on painted slates using machine vision. We begin by outlining the motivations for this research and present a review of research in related areas before proceeding with a process description and a categorization of typical paint defects. We describe the test bed built to replicate factory conditions and the testing of image capture techniques. We discuss problems we confronted such as getting a sufficiently strong signal level from the slate, the effects of the slate surface profile on image capture and how we dealt with these problems. The third principal challenge was to generate a strong signal to noise ratio for each defect type so that a computationally inexpensive image processing method becomes viable. We demonstrate ...

  • PDF

프리캐스트 콘크리트 모듈러 단독주택 설계 개발 및 시공 적용에 관한 연구 (A study on design development and construction application of precast concrete modular house)

  • 서동원;전상훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2021
  • In this study, Dr. Bae Kyu-woong of the Korea Institute of Construction Technology developed a concrete module that was lightweighted to 1700kN with KC modules and met housing performance standards. It solves Construction lifts problem that was the limit of the PC module, and is an innovative model that greatly improves Construction period and economics with boxed modules, and is manufactured in the factory by extruded molding in vibration, noise, fireproofing standards, etc., and has the advantage of excellent precision and high strength. Therefore, if the framing house of a precast concretecan only be standardized in construction, its potential for growth will be endless. To do this, standardization, standardization, and modularization of the design are essential.

  • PDF

지반진동이 건물의 균열에 미치는 영향에 관한 연구 -부산 안산암지역을 대상으로- (A Study of Effects on Building for Cracks by Ground Vibration -Pusan Andesite-)

  • 안명석;박종남;이영대
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1173-1179
    • /
    • 1999
  • A study was made on crack developments of the nearly building due to rock blasting for road construction at the 623 Common Block near the rear side of the Gamchun Habor. The gelogy of the study area is composed of andesite, which belongs to the Kyungsang System of the Cretaceous Period. For 3 months of blasting events, the vibration velocity data were measured at the site just in front of the K freezing factory. The data were divided into 4 groups according to the period of blasting(i.e, DATA 1, DATA 2, DATA 3 and DATA 4), for deriving K and n values. As a result, DATA 1 shows that K and n were 83.3756 and -0.848, respectively, and then K and n were progressively increased in absolute values for the follow-up groups and the last DATA 4 shows K and n were 2980.4898 and -1.502, respectively. Such differences in K and n values may be due to partly : 1) variations geological characteristics, from the upper rather weathered, fisssuring soft rocks at the earlier stage less weathered and fissuring hard rocks at the later stage of blasting events, and 2) the geometry between the blasting and detecting points.Among the total count of 225 blasting events, the number exceeding the safety limits of 0.5cm/sec was 20(8.9% of the total), the maximum displacement detected at the crack gage was 0.25mm, the level of which is far less to cause the occurrence and development of any cracks to the K factory. Therefore, it was confirmed that there were no damages such as structural failure or safety problem to the building.

  • PDF

토목 발파가 소음, 진동, 부유 분진에 미치는 영향 (Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles)

  • 정진도;정영국
    • 한국환경과학회지
    • /
    • 제13권1호
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

대형조선소 천장크레인 운전원의 용접흄 노출 실태 (Exposure status of welding fumes for operators of overhead traveling crane in a shipyard)

  • 이경민;김부욱;곽현석;하현철
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

LonWorks/IP 가상 디바이스 네트워크에서 외란관측기와 ZPETC를 이용한 추종제어 (Tracking Control using Disturbance Observer and ZPETC on LonWorks/IP Virtual Device Network)

  • 송기원
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.33-39
    • /
    • 2007
  • LonWorks/IP VDN은 LonWorks 디바이스 네트워크와 IP(데이터) 네트워크와의 통합네트워크로 산업현장에 대한 유비쿼터스 접근을 제공하여 설비에 대한 예지 및 예방보전을 가능하게 한다. 산업현장에 대한 예지 및 예방보전을 위한 실시간 분산제어 환경에서 즉각적인 응답은 필수불가결한 요소이다. LonWorks/IP 가상 디바이스 네트워크(VDN) 상에서 불확실한 시간지연은 산업현장에 대한 실시간 예지 및 예방보전을 위해 분산 제어를 수행할 때 시스템의 안정성과 성능을 악화시킨다. 따라서 네트워킹 된 분산제어시스템의 안정성을 보장하고 성능을 개선하기 위해서는 시간에 따라 가변적인 불확실한 시간지연을 보상할 필요가 있다. 본 논문에서는 LonWorks/IP VDN와 같은 분산제어 환경 하에서 서보 제어를 수행하는 경우에 외란관측기와 위상지연 보상기로 ZPETC(Zero Phase Error Tracking Controller)를 도입한 제어구조가 제시되고 컴퓨터 모의실험이 수행된다. 제안된 제어기의 성능은 컴퓨터 모의실험을 통하여 외란관측기를 도입한 Smith 예측기 기반의 내부모델제어기(IMC)의 제어결과와 비교 제시된다. 제안된 제어기는 외란과 잡음에 강인한 특성을 가지며, 주기적인 신호에 대한 추종성능을 상당히 개선시키므로 가변적인 시간지연을 갖는 LonWorks/IP VDN 상에서 주기적인 작업 수행에 필요한 분산 서보제어에 매우 적합하다.

만성적 소음노출이 혈압에 미치는 영향에 대한 코호트연구 (Cohort Study for the Effect of Chronic Noise Exposure on Blood Pressure among Male Workers)

  • 차태준;김장락;강위창;양승림;이충렬;유철인;이지호
    • Journal of Preventive Medicine and Public Health
    • /
    • 제35권3호
    • /
    • pp.205-213
    • /
    • 2002
  • 장기간의 소음노출에 의한 혈압상승 또는 고혈압의 발생에 대해서는 많은 연구에도 불구하고 결과가 다양하고 논란이 많은 실정이다. 이에 연구자는 혈압에 대한 소음의 영향을 보다 정확히 평가하기 위해서 일개 사업장을 대상으로 유사 노출군의 코호트를 구성하고 9년간의 추적조사를 실시하였다. 여기서 얻은 자료를 이용하여 소음노출수준별로 혈압의 연도별 변화경향을 파악하고, 혼란변수를 통제한 상태에서도 혈압의 변화에 대해 소음노출이 영향을 미치는가를 파악하고자 하였다. 부산지역의 일개 금속제품 제조업에서 근무하고 있는 530명의 남자 근로자를 1991년부터 1999년까지 혈압을 9년간 매년 계속 추적조사 하였으며, 조사 대상자들을 근무여건과 노출되는 소음수준(noise level category, 이하 NLC로 약함)에 따라 NLC-I (사무실 근로자, 60dB(A) 미만으로 노출, 155명), NLC-II(현장 기술지원자 및 검사원, 소음에 비정기적으로 노출, 75명), NLC-III (현장근로자, 85 dB(A)이하로 노출, 귀마개 또는 귀덮개를 착용, 167명), NLC-IV (현장근로자, 85 dB(A) 초과 노출, 귀마개와 귀덮개를 동시에 착용, 133명) 의 4군으로 구분하였다. 추적기간동안 소음수준별 혈압은 분산 분석을 이용하여 비교하였고, 혼합선형모형을 이용하여 추적기간동안(1992-1999년)의 보정된 통합평균혈압을 구하고 소음노출수준별로 비교하였다. 고려된 혼란변수는 기준연도(1991년)의 연령, 흡연여부, 음주량, 운동, 고혈압 가족력, 수축기 및 확장기 혈압과 체질량지수의 변화였다. 기준연도의 혈압과 혼란변수를 보정한 상태에서 각 연도별 혈압을 비교한 결과 수축기혈압은 9년째에서, 확장기 혈압은 2년째에서 대조군과 통계적으로 유의한 차이가 있었으며, 대조군의 평균 혈압이 전반적으로 증가되었다. 추적기간동안 혼란변수를 보정한 통합수축기 혈압은 대조군인 NLC-I과의 차이가 NLC-II는 1.7 mmHg, NLC-III는 2.0 mmHg, NLC-IV는 3.8 mmHg이었고, NLC-IV의 경우 그 차이가 통계학적으로 유의하였다. 확장기혈압의 경우에는 소음노출수준별로 유의한 차이가 없었다. 본 연구는 남성근로자에서 장기간의 소음노출은 혈압의 상승에 독립적인 영향이 있음을 시사하였다.