• Title/Summary/Keyword: Facility standard

Search Result 930, Processing Time 0.029 seconds

Study on the Calculation of Appropriate Scale of Each Area When Planning Fitness Center (휘트니스센터 계획시 시설별 규모산정에 관한 연구)

  • Cho, Young-Youn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.281-288
    • /
    • 2006
  • Fitness center which was first introduced through hotel fitness has been disseminated into country over the years and these days it becomes a public sports facility that is available even in a small city. Fitness center usually requires a space more than 500 pyeong and even in a small fitness facility at least 200-300 pyung is in need. Also, complex structure including a space for preparing exercise and other subsidiary facility is necessary as well as various service areas to perform various exercise programs. In case of domestic fitness centers, however, proper standard and data required to compute the scale of each service area is not available due to the short of piling data. Therefore computing each space totally depends on an instinct decision of a designer or client, which may cause the fail of effective use of space. This paper aims to calculate appropriate use of space, that is, the over all space, equipment size, and movement line of each area as well as preference and frequence of use among areas is estimated in order to apply those data when computing appropriate estimation of scale.

A Study on the Collecting Method of Reliability Database for Gas Facilities (가스설비의 신뢰도데이터 수집방법에 관한 연구)

  • Rhie, Kwang-Won;Yoon, Ik-Keun;Han, Sang-Tae;Oh, Sin-Kyu;Kim, Tae-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2008
  • The safety assessment for facility industry is now being periodically performed. For the purpose of scientific safety management, QRA(Quantitative Risk Assessment) is also being performed, and reliability data of the facilities is essential to perform the assessment. Generally, the existing safety assessment is performed by using the values announced in other industry processes, which result in the drop of reliability. In order to solve this problem, there is an urgent need to establish reliability database for the facilities. The most appropriate method is to perform a direct reliability analysis towards the facilities undergoing safety assessment. In this study, in compliance with the assessment method and procedure of OREDA-2002 handbook, the facility reliability data are collected, which include the calendar time and operational time in terms of different facility items, the number of failures in terms of different failure mode, the mean, standard deviation, lower limit and upper limit of failure rate, and the failure rate. And the data process method for this special occasion is also proposed when the number of failure is 0.

Development of Competency and Behavioral Indicator of an Administrator in Long-term Care Facility (노인요양시설 관리자의 역량 및 행동지표 개발)

  • Kim, Ji-Soo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.14 no.4
    • /
    • pp.477-487
    • /
    • 2008
  • Purpose: The purpose of this study is to develop the competencies of the administrator and the behavioral indicators, and with those as the foundation it is to measure the importance and the performance. Method: On the basis of literature review, the researcher made a preliminary competency and the behavioral indicator for the administrator. Developed competency and behavioral indicator went through the content validity using CVI. Finally, 20 different competencies and 87 behavioral indicators of the administrators in long-term care facility helped measuring the importance of the present administrator's competency and the performance. Results: The competencies are Achievement Orientation, Initiative, Information Seeking, Interpersonal Understanding, Customer Service Orientation, Marketing, Influence, Organizational Awareness, Relationship Building, Staff Development, Assertiveness, Teamwork and Cooperation, Leadership, Analytical Thinking, Conceptual Thinking, Managerial Expertise, Self Control, Self Confidence, Flexibility and Organizational Commitment. For the contents, 87 behavioral indicators are included. The importance and the performance were confirmed by Importance Performance Analysis. The importance of each behavioral indicator in each field and the performance were confirmed with the mean and the standard deviation. Conclusion: The competencies and behavioral indicators of an administrator which were developed by this study are considered that they can be used as the effective guides in the practical field and can also be used as basic materials for developing educational program.

  • PDF

Test-Bed Establishment Scheme for Terrestrial Laser Scanner' Performance Evaluation (지상레이저스캐너 성능평가를 위한 테스트베드 구축 방안)

  • Lee, In-Su;Tcha, Dek-Ki;Kim, Su-Jeong;Kim, Jin
    • Spatial Information Research
    • /
    • v.17 no.1
    • /
    • pp.39-49
    • /
    • 2009
  • 3D terrestrial laser scanners record high precision three-dimensional coordinates of numerous points on an object surface in a short period of time, and is applied to a wide variety of fields including geodesy, and civil engineering, archaeology and architecture, and emergency service and defence, etc. However, most of terrestrial laser scanner utilized in homeland, were imported from foreign country, and also was not authorized formally as the surveying instrument. Therefore, standard test facility to calibrate and perform its evaluation in order to utilize it in a variety of fields is required. This study deals with the test facility of foreign countries for terrestrial laser scanner and suggest the establishment scheme of domestic test facility.

  • PDF

The MARS Simulation of the ATLAS Main Steam Line Break Experiment

  • Ha, Tae Wook;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.112-122
    • /
    • 2014
  • A main steam line break (MSLB) test at the ATLAS facility was simulated using the best-estimate thermal-hydraulic system code, MARS-KS. This has been performed as an activity at the third domestic standard problem for code benchmark (DSP-03) that has been organized by Korea Atomic Energy Research Institute (KAERI). The results of the MSLB experiment and the MARS input data prepared for the previous DSP-02 using the ATLAS facility were provided to participants. The preliminary MSLB simulation using the base input data, however, showed unphysical results in the primary-to-secondary heat transfer. To resolve the problems, some improvements were implemented in the MARS input modelling. These include the use of fine meshes for the bottom region of the steam generator secondary side and proper thermal-hydraulics calculation options. Other input model improvements in the heat loss and the flow restrictor models were also made and the results were investigated in detail. From the results of simulations, the limitations and further improvement areas of the MARS code were identified.

Development of Displacement Measuring Sensor Module to Monitoring About Variation and Distortion for Bridge Infrastructure at Wireless Communication Environmental (교량구조물의 구조적 변형을 측정하는 무선통신기반 변위센서모듈 개발)

  • Ryu, Seung-Ki;Moon, Hak-Yong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.87-95
    • /
    • 2010
  • Lots of bridge structure generated the change of outward formation according to durability capability and decrepitude by long use. Especially, in case of the typhoon, snowing and earthquake is going to make rapidly more worse formation about the old structural facilitys. Also, outward formation by irregular and micro-distortion in bridge structure could not easily checked by normal diagnostics method. As a result, performance-capability of structure facility is getting to make a decline in standard of structure performance. Recently, real-time monitoring technology by wireless environment go into the study of irregular movement for structure facility. This paper presents the development of sensor to displacement checking about bridge structure. Sensing method of developed sensor put bring into the gyroscope technology using the acceleration speed and angular acceleration speed. This paper also will simulated to verified the monitoring capability of developed sensor against random vibration, frequency and distortion in simulated equipment.

Empirical Investigation and Comparative Analysis of Underground Public Pedestrian Facilities in Daegu Metropolitan City

  • Lee, Gahng-Ju;Jung, Seong-Hwan
    • Architectural research
    • /
    • v.15 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • The study establishes the analytical frame composed of 22 items according to the category of passageway, shop, entrance and amenity for the purpose of executing the empirical investigation of the Underground Public Pedestrian Facilities in Daegu Metropolitan City of Korea. As a result of the research work, the study finds out some problems about the facilities as follows: (1) Passageway elements - the skylight was constructed only in one place. In contrast, the standards of passageway and plaza were well-fulfilled except for one or two cases. (2) Shop elements - the cases of installing shops where they should not be located were found the most, and a case of over-establishing the shop area was found as well. (3) Entrance elements - the cases not matching roof or canopy standard over entrance facilities were found the most. Overall, the entrances and their connection to the adjacent buildings are appraised as not well-established. (4) Amenity elements - these were appraised as insufficient in all except two cases. Regarding this, not only necessary are the establishment of facilities and the effort of facility managers, but also urgent is the institutional improvement.

Numerical Predictions of Fire Characteristics of Passenger Train Fire in an Underground Subway Tunnel, Depending on Change of Location of Ventilation Facility (지하철 터널내의 객차 화재발생시 환기실 위치변화에 따른 화재특성의 수치적 연구)

  • Son, Bong-Sei;Chang, Hee-Chul
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.1-8
    • /
    • 2008
  • The study is to perform numerical analysis of train fire characteristics in an underground subway tunnel, depending the different locations of ventilation facility. To study the characteristics of train fire, two kinds of worst-case scenarios are selected, based on escape distance, escape time, and fire zone, and trends and thermal environments of tunnel are analyzed by changing the locations of ventilation facility for times. Fire characteristics is calculated by using FLUENT v.6.3.26, and turbulent flow is calculated by using the standard k-${\varepsilon}$ model. The numerical results show distribution of carbon monoxide concentration, temperature, and velocity. The results of this study will contribute to building the most suitable ventilation systems when designing subway stations and tunnels.

A study on the application of the extreme value distribution model for analysis of probability of exceeding the facility capacity (시설용량을 초과하는 폐수량의 유입확률 분석을 위한 극치분포모델의 적용에 관한 연구)

  • Choi, Sunghyun;Yoo, Soonyoo;Park, Taeuk;Park, Kyoohong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.369-379
    • /
    • 2016
  • It was confirmed that the extreme value distribution model applies to probability of exceeding more than once a day monthly the facility capacities using data of daily maximum inflow rate for 7 wastewater treatment plant. The result of applying the extreme value model, A, D, E wastewater treatment plant has a problem compared to B, C, F, G wastewater treatment plant. but all the wastewater treatment plant has a problem except C, F wastewater treatment plant based 80% of facility capacity. In conclusion, if you make a standard in statistical aspects probability exceeding more than once a day monthly can be 'exceed day is less than a few times annually' or 'probability of exceeding more than once a day monthly is less than what percent'.

Design considerations for teleoperation systems operating in gas-tight argon cells

  • Yu, Seungnam;Lee, Jongkwang;Park, Byungsuk;Cho, Ilje;Lee, Hyojik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1717-1726
    • /
    • 2017
  • In the nuclear industry, mechanical engineers spend a significant portion of their time designing equipment such as manipulators, bogies, mechanical grippers, and so on. Some customized designs can be considered as standard mechanical equipment in this area, although it is not unusual to find that an existing design cannot simply be copied from one project to another. Varied performance requirements can dictate that redesign, often quite extensive redesign, is required. However, if something similar has been done before, engineers could use that as a starting point for the new project. In this regard, this study presents several guidelines inspired by previous design knowledge for similar development cases. Moreover, this study presents more detailed suggestions such as design guidelines for an argon-based hot cell atmosphere and design experience for a large-scale practical hot cell facility. Design considerations and case studies dealt with in this study are dedicated to teleoperation manipulators that are used at a large-scale argon cell facility for pyroprocess integrated inactive demonstration (PRIDE), at the Korea Atomic Energy Research Institute. In particular, for case studies to support the suggested recommendations, a fabricated telemanipulator system for PRIDE is introduced, and several kinds of experimental results associated with it are presented.