Implementation of Facility Management System for Plant Factory (식물공장 시설관리 시스템의 구현)

  • Lee, Yong-Woong;Seo, Beom-Seok;Kim, Chan-Woo;Kim, Kyung-Hee;Park, Yang-Ho;Shin, Chang-Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.141-151
    • /
    • 2011
  • This paper suggests the Facility Management System for plant factory promising to be a core technology of the agriculture in the future. This system makes diagnoses that status from sensors or facilities in the factory for exact operation and monitors the internal environment with the control status in real-time. It is expected that we could operate a plant factory safely and effectively by using the system. The system consists of the data management module, the context provider module, the context interpreter module, the service provider module, the data storage and user interface. The system provide with the failure diagnosis service, the facility control service, and the high-reliability monitoring service via the interactions between above modules. The failure diagnosis service determines whether the sensors or facility devices are in failure or not, and informs the administrator of their conditions. The facility control service is activated in case if the facilities need to be managed during the diagnosis for failure or malfunction processes. The high-reliability monitoring service provides the administrator with verified data through the failure diagnosis service. Then we confirmed that the suggested system operates correctly through the system simulation.

IDENTIFICATION CODE OF INTERSTELLAR CLOUDS WITHIN IRAF

  • Lee, Young-Ung;Jung, Jae-Hoon;Kim, Hyun-Goo
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.185-196
    • /
    • 1997
  • We present a code which identifies individual clouds in crowded region using IMFORT interface within Image Reduction and Analysis Facility (IRAF). We define a cloud as an object composed of all pixels in longitude, latitude, and velocity that are simply connected and that lie above some threshold temperature. The code searches the whole pixels of the data cube in efficient way to isolate individual clouds. Along with identification of clouds it is designed to estimate their mean values of longitudes, latitudes, and velocities. In addition, a function of generating individual images (or cube data) of identified clouds is added up. We also present identified individual clouds using a $^{12}CO$ survey data cube of Galactic Anticenter Region (Lee et al. 1997) as a test example. We used a threshold temperature of $5\sigma$ rms noise level of the data With a higher threshold temperature, we isolated subclouds of a huge cloud identified originally. As the most important parameter to identify clouds is the threshold value, its effect to the size and velocity dispersion is discussed rigorously.

  • PDF

Effective modular assembly line control system

  • Eom, Eu-Gan;Kim, Dong-Shin;Ahn, In-Seok;Park, Jong-Oh;Kim, Young-Tae;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.293-297
    • /
    • 1993
  • In this paper, a new design method for Assembly Line Control System(ALCS) is presented. This system consists of five independent modules having their own specific functions such as production management, facility management material management, quality management, and remote control. To implement the ALCS, we propose design of the common data management module(CDMM). This module has the roles of integrating the above five modules and of communicating the common data between them. Using this method, we realize an information management method in the view of CIM. In addition, we standardize the inter-communication of common data between machines having different interface protocols.

  • PDF

A Spread Sheet Model for a Long Range Water Supply Planning (장기 용수 공급계획 수립을 위한 스프레드 쉬트 모델)

  • 김승권
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1992.07a
    • /
    • pp.479-489
    • /
    • 1992
  • A mathematical model for a long range water supply planning is develoted as a dynamic capacitated facility location problem, in which operation costs and two types of fixed costs are considered. The fixed costs are for water supply systems such as dams and reservoirs and for water conveyance systems of waterways or conduits from each water supply points. A Spreadsheet model is developed to support the efficiency of user interface and to implement a heuristic solution procedure. The proposed solution procedure utilizes SOLVER tool and it has been applied to a system with fictitious data but with reality and applicability in mind. As a result of the mathematical analysis, not only the most economic construction timings of surface water supply facilities and distribution systems but also the most economical water supply operating patterns are identified.

  • PDF

On-line Monitoring and Diagnostics for Distribution Panel System (배전반 시스템의 온라인 감시 및 진단)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.106-110
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Development of Ambulatory Speech Audiometric System (휴대용 어음청력검사 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Sang-Min;Im, Won-Jin;Lee, Jeong-Whan;Kim, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.645-654
    • /
    • 2009
  • In this study, we present an efficient ambulatory speech audiometric system to detect one's hearing problems at an earlier stage as possible without his or her visit to the audiometric testing facility such in a hospital or a clinic. To estimate a person's hearing threshold level in terms of speech sound response in his or her local environment, a digital assistant(PDA) device is used to generate the speech sound with implementing audiometric Graphic User Interface(GUI) system. Furthermore, a supra-aural earphone is used to measure a subject's hearing threshold level in terms of speech sound by the compensating the transducer's gain by adopting speech sound calibration system.

Supporting System far Safe Appraisal and Management of Agricultural Structures using Relational Database and Geographic Information (관계형 데이터베이스와 지형정보를 이용한 농업구조물의 안전점검 및 이력관리 지원시스템)

  • 김종옥;김한중;이정재;고만기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.3
    • /
    • pp.101-110
    • /
    • 2002
  • Most of the agricultural structures are in shortage of feasible facility management because these structures are small in size and spacially distributed in rural area. Inspection tools based on visual inspections are generally used for agricultural structures in most of the countries, including Korea. It is necessary to survey data of the irrigation structures to maintain records, and to develop the interface program by constructing database of inspection data. This study was conducted to develop a system for safe appraisal and repair works on agricultural irrigation structures. Repair and rehabilitation method can be chosen from an optimum viewpoint if the information between the method and life-cycle management cost of agricultural structures is constructed in the database. In this study, the system assisting onsite field investigation and determining the typical rehabilitation method of typical agricultural structural problems such as fractures and cracks of members was developed.

Radiation level distribution monitoring system (방사선 분포 모니터링 시스템)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.828-831
    • /
    • 1996
  • Radiation monitoring system is needed at nuclear power plant and nuclear facility. Manual survey techniques are commonly used, but they are time consuming and somewhat inaccurate. Automatic radiation surveys are very important because it provides significant savings in men-rem and wages. Unmanned, remote automatic radiation measurement system should be small and light-weighted in order to mount on robotic system. The system we have developed consists of detection parts, signal processing part, interface, and software part. Position information is provided by using of a collimator. The measurement process is achieved by the scanning of detector and image processing techniques are used to display radiation levels. We designed collimators, detectors, signal processing circuit, and constructed prototype system. The goal of this system is the mapping of camera image and radiation level distribution.

  • PDF

A Study on Constructing the Automatic Control System of the Power Cable lest Facility (배전급 전력케이블 장기열화설비 자동화시스템 구축에 관한 연구)

  • Kang Moon Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.512-514
    • /
    • 2004
  • 배전급 전력케이블의 장기수명특성 평가를 위한 기초자료를 확보하기 위해 고창 배전 실증시험장내에 장기열화시험을 수행할 수 있는 실증시험설비가 구축되었다. 이 설비를 안전하고 효과적으로 관리 운영하기 위해 원격감시제어기능, 자동운전기능 및 열화데이터의 효과적이 처리기능이 포함된 장기열화설비 자동화시스템의 구축이 필요하였다. 따라서 본 논문에서는 새롭게 개정된 한전 표준구매규격과 참고규격인 개정판 AEIC CS5 규격에 맞게 구축된 배전급 전력케이블 장기 열화시험설비를 원격감시제어, 자동운전 및 열화 데이터의 저장 및 처리가 가능한 전력케이블 장기열화설비 자동화시스템의 하드웨어 구성 및 MMI (Man-Machine Interface)화면의 구성방안에 대하여 기술하였다. 본 자동화시스템을 이용해 기존의 간이 차수형 CNCV케이블의 AEIC규격 수트리시험을 안전하게 수행하였다.

  • PDF

MASS CODES OF MOLECULAR CLOUDS WITH IN IRAF

  • Lee, Young-Ung
    • Publications of The Korean Astronomical Society
    • /
    • v.9 no.1
    • /
    • pp.39-54
    • /
    • 1994
  • We present two codes which estimates virial mass and LTE mass using IMFORT interface within IRAF (Image Reduction and Analysis Facility). It is discussed that threshold value (temperature or CO integrated intensity), which defines a reasonable cloud boundary and size, is the most important parameter determining accurate results. Several virial masses are to be obtained using the vir task, as well as three velocity dispersions including the centroid velocity dispersion, a turbulence indicator. LTE mass is to be estimated by using task lte as well as three by-product images. The $^{13}CO$ abundance and threshold temperature of $^{13}CO$ and $^{12}CO$ peak temperatures are the most critical parameters in LTE technique.

  • PDF