• Title/Summary/Keyword: Facility design and construction

Search Result 501, Processing Time 0.029 seconds

A Study on the Characteristics of Consumer Visual-Perceptional Information Acquisition in Commercial Facilities in Regard to its Construction of Space from Real-Time Eye Gaze Tracking (상업시설 공간구성의 실시간 시선추적에 나타난 소비자 시지각 정보획득 특성 연구)

  • Park, Sunmyung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.3-14
    • /
    • 2018
  • For satisfying consumer needs, commercial facilities require a variety of sale-related space expressions and eye-catching product arrangements; space composition can also be a direct marketing strategy. The human eye is the sensory organ that acquires the largest amount of information, and an analysis of visual information helps in understanding visual relations between . However, the existing studies are mostly focused on analysis of still frames in experimental images, and there is a lack of studies analyzing gaze information based on mobile images of commercial spaces. Therefore, this study analyzed emotional responses through gaze information of space users in reality using a video of a movement route through a commercial facility. The analysis targeted straight sections of the moving route; based on the data acquired, sectional characteristics of five gaze intensity ranges were examined. As a result, section A, the starting point of the route, had a low gaze intensity, while section B had the highest gaze intensity. This indicates that, starting in section B, the subjects explored the space in a stable way and needed time to adapt to the experimental video. In relation to space characteristics of the gaze-concentrated area, display formats of the right stores in 4 of 6 sections received greater attention. The gaze of consumers was mostly focused on props, and big gaze information was revealed in showcase display formats of the stores. In conclusion, this analysis method can provide highly useful direct design data about merchandise display and merchandise component arrangement based on consumer visual preference.

A Study on Space Construction for the Aged's Welfare Center in Japan - Focusing on the Aged's Welfare Center in Utsnomiya City - (일본 노인복지센터의 공간구성에 관한 연구 - 우츠노미야시 지역의 노인복지센터를 중심으로 -)

  • Yoo Eun-Yeong
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.155-162
    • /
    • 2006
  • Today, according to population decrease and aging of the old due to the decline of birthrate in our society in $21^{st}$ century, there is a stiff increase of the aged group. Complying with the request of epic needs, as there was a full scale amendment of law of the aged welfare in 1997, the centers appeared differently based on the regional dimension, the difference of the number of persons to be accommodated, and the social and economic characteristics. Coping with these problems occurring, along with the necessity of welfare facilities for the leisure of the aged, the government prepared and carried out a number of plans for the service of the aged and securing of facilities. This practice of the government, however, centered on the crease of service in quantity other than the quality, resulting in a situation of lacking the welfare facilities for the aged meeting the requirement of the aged in their aspect of consumer. On the contrary, building the welfare centers in Japan started in 1960 with a rapid increase of the number of centers in 1970s, and there were 2,214 welfare centers in operation in Japan in 1995, keeping a high level of service in quality and quantity. Thus, this study aims to present basic materials necessary for the criteria of space designing plans for the aged welfare centers in Korea through case analysis of the facility criterion, area constitution and space constitution by the floor that play an important role in regional welfare facilities for the aged in Japan.

  • PDF

Estimation of Optimal Size of the Treatment Facility for Nonpoint Source Pollution due to Watershed Development (비점오염원의 정량화방안에 따른 적정 설계용량결정)

  • Kim, Jin-Kwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.149-153
    • /
    • 2008
  • The pollutant capacity occurred before and after the development of a watershed should be quantitatively estimated and controlled for the minimization of water contamination. The Ministry of Environment suggested a guideline for the legal management of nonpoint source from 2006. However, the rational method for the determination of treatment capacity from nonpoint source proposed in the guideline has the problem in the field application because it does not reflect the project based cases and overestimates the pollutant load to be reduced. So, we perform the standard rainfall analysis by analytical probabilistic method for the estimation of an additional pollutant load occurred by a project and suggest a methodology for the estimation of contaminant capacity instead of a simple rational method. The suggested methodology in this study could determine the reasonable capacity and efficiency of a treatment facility through the estimation of pollutant load from nonpoint source and from this we can manage the watershed appropriately. We applied a suggested methodology to the projects of housing land development and a dam construction in the watersheds. When we determine the treatment capacity by a rational method without consideration of the types of projects we should treat the 90% of pollutant capacity occurred by the development and to do so, about 30% of the total cost for the development should be invested for the treatment facility. This requires too big cost and is not realistic. If we use the suggested method the target pollutant capacity to be reduced will be 10 to 30% of the capacity occurred by the development and about 5 to 10% of the total cost can be used. The control of nonpoint source must be performed for the water resources management. However it is not possible to treat the 90% of pollutant load occurred by the development. The proper pollutant capacity from nonpoint source should be estimated and controlled based on various project types and in reality, this is very important for the watershed management. Therefore the results of this study might be more reasonable than the rational method proposed in the Ministry of Environment.

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

A Folkloric Demonstration on 'Sam-gama' The Field Report on the Construction, Structure and Utilization of 'Sam-gama' ('삼가마' 유구에 대한 민속학적논증 '삼가마'(삼굿)의 축조와 구조, 운용에 대한 현지조사 보고)

  • Lim, Hyoung Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.4
    • /
    • pp.4-19
    • /
    • 2009
  • Though admitting that, in light of the recent archaeological trend, the excavation on relics of Sam-gama (a sort of kiln steaming the hemp) is increasingly reported, little efforts by far have been made not only to restore its traditional structure design but also to research hardly the change of hemp-steaming technologies in ages. In this regard, this paper shows the exploration of structural method and design as well as operability with regard to Sam-gut, traditional hemp-processing equipment that was recently reconstructed in Jungsun, Kangwon Province. Samgut, generally positioned at the waterside area, is an traditional device for steaming hemp to get bast fibers from the raw material of hemp, principally consisting of HWA-JIP(fire-place) to obtain steams by feeding fire ad Mong-got(boiling chamber) to make the hemp steamed after stacking. More specifically, thick round-logs were piled at the bottom of Hwajip prior to stacking stones around its circumferential area. When the timber positioned below gets burned with high temperature to heat stones existing in the upper side, waters then poured onto it after laying a bundle of grass and soil up to the boiled stones. If so, there generates hot vapor, which is conveyed to Monggot to steam the hemp. Functionally, it is of outstanding importance that Samgut is capable of producing high-temperature water vapors instantaneously under the intensive manpower, thus being constructed achievable for those purposes. The Samgut made by digging the ground is an instant facility that is closed after use. The remains, which were used to generate higher thermal power for steaming hemp, make it hard to excavate the historic traits because there left little vestiges in the soil, which means keen attention must be paid to find out the trace of Smgama relics. Future research stall be focused on collection of broader data regarding Samgut including technological review in extracting bas fibers from the hemp.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Ecological Renewal Plan of Urban Parks for the Revitalization of Urban Green Axis in Gangdong-Gu (강동구 도시 녹지축 기능 활성화를 위한 도시공원의 생태적 리뉴얼 방안 연구)

  • Park, Jeong-Ah;Han, Bong-Ho;Kwak, Jeong-In
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.12-27
    • /
    • 2023
  • In this study, among the construction-type parks in Gangdong-gu, targeting parks with high environmental and ecological value located on the urban green axis, a plan was prepared for the ecological renewal of urban parks, and a design that applied to them was proposed. The renewal target site was selected by analyzing the general condition of Gangdong-gu and urban parks, the land use and green area ratio, park green area, and the green axis of Gangdong-gu. Gangdong-gu has 54 parks, including 2 neighborhood parks and 52 children's parks. In the first stage of the current status review, 17 parks were extracted through locational value analysis, such as location and adjacency to the natural axis and green axis. In the second stage, eight parks were selected among the first-stage extraction parks based on the ratio of green spaces and open spaces within each park service area. In the third stage, two of the second stage extraction parks were selected based on whether the legal standard of the park area was met, and in the fourth stage, one of the third stage extraction parks was selected through an aging survey of the park. As for the urban ecological status of the renewal target site, the status of land use in the aspect of entropy reduction, the status of soil cover in the aspect of water circulation, and the status of planting structure in the aspect of biodiversity were investigated. As for the status of the three renewal sites, the green area was insufficient at 18.3-45.3%, and the facility area was 54.7%-81.7%, which was judged to have low urban temperature reduction effects. The impervious pavement area accounted for 34.5% to 48.9% of the park area, accounting for most of the facility area, and it was judged that the water circulation function was insufficient. The planting structure consisted of a single layer and a double layer structure, and although the tree layer was good, the lower vegetation was poor, and there was no planting site of edible plants or large hardwood trees, so the biodiversity was low. After the ecological renewal design of Seonrin Children's Park, Dangmal Children's Park, and Saemmul Children's Park, which were selected as the renewal targets in this study, the ecological area ratio of each park increased by 1.4 to 3 times than before the renewal. If the urban parks located on the urban green axis are examined from the perspective of the urban ecosystem and renewed ecologically, it is judged that the expected effect will be high in reducing entropy, improving water circulation, and laying the foundation for biodiversity in terms of the urban ecosystem.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Analysis of Current Status and Teacher Librarians' Perception about Space Composition and Interior Environment of School Libraries (학교도서관 공간 영역 및 실내 환경 요소의 구성 현황과 사서 교사 인식 분석)

  • Song, Gi-Ho;Kang, Bong-Suk
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.31 no.1
    • /
    • pp.67-87
    • /
    • 2020
  • The purpose of this study is to analyze current status and teacher librarians' perceptions of school library space composition and indoor environment, and propose some methods for the school library to be a basic educational facility. The space most secured by the 126 teacher librarians who participated in the survey was the free reading area, and the space with the lowest level was the media production and group project area. The most important types of spaces for teacher librarians are the teaching area and the free reading area, while the recognition of the importance of media production and group project areas is relatively low. Among the elements of indoor environmental assessment, they showed that safety and comfort were the most important but diversity and flexibility were relatively less important. The result of this analysis is different from the school and library policy direction that emphasizes the learning commons and maker spaces. Teacher librarians still seem to appreciate the importance of traditional library space. Therefore, it is necessary to include the establishment and operation of maker spaces and learning commons in the teacher librarians training and retraining process. In addition, it is necessary to increase the participation of users such as teachers, students, and parents in space composition and interior design initiatives to increase the user's interior environment satisfaction.

A study on the Improvement of Design Guideline for the Use Enhancement of Privately Owned Public Space (공개공지(公開空地) 효용성(效用性) 제고(提高)를 위한 설계지침(設計指針) 개선(改善) 방안(方案))

  • Park, Jung-Lim;Kim, Hyun-Jun;Kwon, Young-Hyoo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.3
    • /
    • pp.115-141
    • /
    • 2011
  • In urban space, public space is publicly or privately owned space freely accessible by the public. Privately owned public space to the public hosts small-scale rest facilities to serve the public in buildings of certain purposes and sizes for the sake of pleasant urban environment. The Building Act and building ordinances formulate a set of criteria for management and easement of construction standards as well as the area. When creating privately owned public space, one can get incentives through the easement of floor space index and height limit. The purposes of this study were to investigate and analyze privately owned public open space, which is freely accessible by the public, and its adjacent streets and to propose plans to improve the regulations for securing privately owned public space for more rational and practical legal applications. The study then proposed some plans to help to increase the quality of privately owned public space including applying the coefficient to suggest the type of privately owned public space fit for the features of the streets and measure the appropriate utility level differently and distinguishing the mandatory items according to the facility regulations in privately owned public space from the ones qualified for additional points in case of installation. The types of privately owned public open space should be applied differently and the content of facilities intended should be different according to whether it will serve as a resting place or grant more importance on traffic by walking, depending on the features of its adjacent streets. The privately owned public space, the frontage space of building, and the adjacent sidewalks should become a whole and be regarded as one space from the integrated perspective. The results of the study claim further significance in that it investigated privately owned open space and roadside across Seoul. They will serve as useful data to solve the problems with the privately owned public space of the city, which destroys spatial continuity by focusing on the quantitative increase of privately owned open space and creating individual privately owned open spaces and builds high-rise buildings alienated from the existing spaces, and to increase the quality of future privately owned public space.