• 제목/요약/키워드: Facility Safety

Search Result 1,956, Processing Time 0.034 seconds

Development on the Safety Management System of Hazardous Chemicals under the Chemicals Control Act: Focusing on Safety Assessment System (화학물질관리법상의 유해화학물질 안전관리 개선방안 연구 : 안전성평가 사례 중심)

  • Yoo, Byungtae;Lee, Eun Byul;Kim, Jong Gu
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.96-101
    • /
    • 2019
  • Chemicals Control Act have been strengthened to control more safely hazardous chemicals from 2015. In particular, the standards for the installation and management of handling facilities was enhanced with specific regulations depending on type of the facilities and the hazardous chemicals. However, some standards for handling facilities caused difficulties in implementing the strengthened standards due to various field conditions, such as lack of physical space. The Ministry of Environment is implementing Safety Assessment System (SAS) to solve these problems since 2018. However, many plants have difficulties in preparing alternative methods to pass the safety evaluation. The purpose of this study was to review and analyze the SAS and to suggest alternative measures in terms of management and technical aspects through the case study of hydrochloric acid storage tanks. The following safety solutions were suggested for handling facilities that had insufficient the space and capacity for the retaining wall due to physical space. Firstly, insufficient space was resolved by introducing equipment relocation or demolition, and retaining wall expansion. Secondly, the wall of the surrounding buildings was used as an alternative to the retaining wall with additional chemical resistant treatment. Finally, sensor installation and facility inspection were suggested as ways to improve chemical safety. Therefore, improvement of chemical accident prevention system is required not only in terms of facilities supplementation but also management aspect. The results of this study are expected to be available for similar facilities and will be based on the preparation of additional safety assessment as alternatives measures in the future.

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.

The Practical Simplified Equation for Settlement Evaluation of Counter Facility in Soft Ground Centering on Rubble Mound (연약지반에 설치된 항만 외곽시설의 안전점검을 위한 침하 평가 간편식 제안 - 사석경사제 중심으로)

  • Kim, Yong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.317-324
    • /
    • 2020
  • In this study, a simplified equation for settlement evaluation suitable for the special conditions of a counter facility is suggested. Recently, counter facilities, especially breakwaters, are constructed on soft ground in distant seas as new-port development projects. A counter facility that resists the external forces by self-weight settles easily when constructed on soft ground. Settlement in a counter facility and breakwater is not an important factor for maintenance than a land facility. On the other hand, the current settlement evaluation criteria are excessive for conducting a safety inspection. A settlement evaluation from a safety inspection followed by "Detailed Guidelines for a safety inspection on a counter facility" is used. A simplified equation was proposed to calculate the maximum settlement by applying the allowable residual settlement or settlement stability evaluation results. The suitability of the simplified equation was assessed compared to the assessed rating from the settlement survey results. The proposed simplified equation showed that the settlement evaluation rating had been upgraded. The proposed simplified equation is expected to be used to evaluate the practical structural stability and functional performance.

Evaluation of Complexation Suitability of Leisure Facilities for the Elderly in Elementary School - Focused on the Current Condition of Facilities of Elementary School - (초등학교시설의 노인여가복지시설 복합화 적합성 평가 - 초등학교 시설현황을 중심으로 -)

  • Lim, Do-Young;Song, Byung-Joon;Chu, Beom
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.202-211
    • /
    • 2015
  • This study attempts to deduce the necessity and validity of complexation, and suggests complexation through complexation suitability evaluations as follows. First, the concept and current state of leisure facilities for the elderly and elementary facilities and architectural complexation were investigated through theoretical considerations. Second, the target schools for complexation of 'elementary school-leisure facility for the elderly' were selected. The aspects of facility introduction of an elementary school, teacher support facility, convenience facility for the disabled, safety and security facilities as well as school facility accessibility were investigated on the basis of the data attained from theoretical considerations. Third, the feasibility of complexation of leisure facilities for the elderly was reviewed, based on the investigated data on complexation-targeted elementary school. Regarding school building and support facilities, with a focus on leisure programs for the elderly, the availability and number of rooms, extra numbers of regular classrooms and the room condition were assessed on the basis of the analysis of operational perspective of each facility. The convenience facilities for the disabled were examined by classifying them into interventional facility in consideration of facilities for the elderly, pursuant to the provisions in the convenience promotion assurance act for the disabled, elderly and pregnant women. Safety and security facilities were evaluated in an effort to assess the safety issue of the elderly and children. The result of the evaluation of the 6 elementary schools in Seong-buk county based on the above-mentioned four measurement standards shows that they scored 107~124 points out of the total 155 points, with the average of 118.5 points. This is more than the medium score and shows the possible complexation of the elementary school facilities as the leisure facilities for the elderly, and at the same time it may lead each school to find out the elements conducive to enhancing the complexation as a result of the evaluation. Through the evaluation data, I expect that we contribute to promoting the process of the evaluation of the appropriateness of complexation and the efficient complexation.

Condition Estimation of Facility Elements Using XGBoost (XGBoost를 활용한 시설물의 부재 상태 예측)

  • Chang, Taeyeon;Yoon, Sihoo;Chi, Seokho;Im, Seokbeen
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.1
    • /
    • pp.31-39
    • /
    • 2023
  • To reduce facility management costs and safety concerns due to aging of facilities, it is important to estimate the future facilities' condition based on facility management data and utilize predictive information for management decision making. To this end, this study proposed a methodology to estimate facility elements' condition using XGBoost. To validate the proposed methodology, this study constructed sample data for road bridges and developed a model to estimate condition grades of major elements expected in the next inspection. As a result, the developed model showed satisfactory performance in estimating the condition grades of deck, girder, and abutment/pier (average F1 score 0.869). In addition, a testbed was established that provides data management function and element condition estimation function to demonstrate the practical applicability of the proposed methodology. It was confirmed that the facility management data and predictive information in this study could help managers in making facility management decisions.

A Study on the Actual Condition Analysis and Improvement Direction of Disaster Safety Education Training Course in School - Focused on Disaster Safety Management for School Facilities - (학교 재난안전 교육연수과정 실태분석 및 개선방향에 관한 연구 - 학교시설에 대한 재난안전관리 중심으로 -)

  • Lee, Byoung-Ho;Park, Youn-Ju;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.11-21
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

The Appropriation and The Use Scheme of Safety Control Cost for Reducing Severity Rate of Injury on Construction (건설재해 강도율 감소를 위한 안전관리비의 책정 및 사용방안)

  • Kim, Byung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.383-390
    • /
    • 2008
  • Construction safety control system had improved constantly but the severity rate of injury don't reduced, safety level of construction don't progressed as usual. In order to reduce of the severity rate of injury safety control in site is important but it needs to improve form of system that introduce obligation of safety design and design safety appraisement, an effect use method of safety control cost. The safety control cost is problem that reduce than design cost accordance bidding rate and use a little safety facility cost compare with labor cost. This study tried reduce the severity rate of injury by propose effective improvement scheme through relevant problem analysis to the safety control cost and remove caution that the severity rate of injury don't reduced.

Research on the Adequacy and Application of Safety Standards for Station Facility (역시설 안전기준의 적정성 및 적용성에 관한 연구)

  • Kim, Jin-Ho;Sin, Sung-Soon;Kim, Min-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.181-187
    • /
    • 2008
  • In 2004, railway safety law was established since intimidatory factors have increased for railway industry, such as high speed rail, urban transit extension, induction of new transportations. The projects for safety system establishment and guidelines are performed including the safety guidelines for station and platform. Therefore, in this study the safety rules are examined through investigation for stations

  • PDF

Dependence of Explosion Overpressure of Flammable Gas on the Change of Volume Blockage Ratio of Facilities (설비 혼잡도에 따른 가연성 증기운의 폭발과압의 변화)

  • Lee, Seung Kuk;Lee, Da Eun;Kim, Sung Chan;Yoon, Kee Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.54-61
    • /
    • 2015
  • A series of CFD calculation has been conducted to investigate the effect of facility confinement on explosion power for process plant facility. The level of confinement of a facility was simplified with VBR(volume blockage ratio) and averaged size of obstacles. FLACS which is 3D CFD code of gas dispersion and the explosion was used for simulating the explosion phenomena in the idealized domain with different confinement level. The CFD results showed a tendency that the overpressure increases with increasing VBR and number of obstacles. The effect of VBR on the overpressure was relatively small for the case of number of obstacle less than 25. The results of this study can be used to provide a safety guideline considering the facility confinement in case of leakage accident of flammable gas and vapor in process plants.

Study on Improvement of Facility Criteria of Architectural Planning by analysing the State of Safety Accident in Schools - Focused on the Primary Schools in Daejon City - (학교안전사고 실태분석을 통한 건축계획적 시설기준 개선에 관한 연구 -대전지역 초등학교를 중심으로-)

  • Park, Im-Ho;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.2
    • /
    • pp.21-31
    • /
    • 2012
  • This study is with the subjects of 7 primary schools in Daejon City which opened after 2004 when the Ministry of Education & Human Resources Development released the "Study of Developing the Manual for Safety and Plan of school facilities". This is to study the measures of improving or enhancing the safety criteria on the school facilities from the viewpoint of actual planning as well as of architectural planning through investigating and analysing the cause, the status and the type of negligent accidents by school which are occurring both directly and indirectly. Though the analysis of the examined contents shows there is no facility in primary schools not satisfying 'the criteria on safety maintenance of school facilities', the criteria is so comprehensive and general that its content is just itemized and the current criteria of facilities are not fit for the present situation because of the physical condition of the students in elementary, middle and high schools and the changing curriculum.