• 제목/요약/키워드: Facility Safety

검색결과 1,941건 처리시간 0.031초

TRACE V5 CODE APPLICATION DVI LINE BREAK LOCA USING ATLAS FACILITY

  • Veronese, Fabio;Kozlowsk, Tomasz
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.719-726
    • /
    • 2012
  • The object of this work is the validation and assessment of the TRACE v5.0 code using the scaled test ATLAS1 facility in the context of a DVI2 line break. In particular, the experiment selected models the 50%, 6-inch break of a DVI line. The same experiment was also adopted as a reference test in the ISP-503. The ISP-50 was proposed to, and accepted by, the OECD/NEA/CSNI due to its technical importance in the development of a best-estimate of safety analysis methodology for DVI line break accidents. In particular, the behavior of the two-phase flow in the upper annulus downcomer was expected to be complicated. What resulted was the need for relevant models to be implemented into safety analysis codes, in order to predict these thermal hydraulic phenomena correctly.

슬러지 소각시설 악취 및 환기에 관한 연구 (A Study on the Odor and Ventilation in Sludge Incineration Facilities)

  • 서병석;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.7-13
    • /
    • 2020
  • Sludge incineration facilities are socially recognized as a hate facility. Therefore, a careful deodorization plan must be established. Therefore, the incineration facility must conduct research on odor ventilation. In this study, a odor diffusion simulation in an incineration facility was conducted and analyzed. In particular, research was carried out on carry-in rooms, pre-treatment rooms, and storage facilities for crops, which are expected to rapidly spread odor. As a result, ammonia 1.62, hydrogen sulfide 0.63, and acetaldehyde 0.73 were found in the transfer room. In addition, pretreatment rooms and stencil storage facilities were found to be lower than regulatory standards.

Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • 제14권4호
    • /
    • pp.65-69
    • /
    • 2018
  • The objective of this study was to conduct a radiation shielding analysis for the facility equipped with radiation generator. The analysis was carried out in two aspects. First, from the aspect of the effect caused by primary and leakage radiation. Second, effect of scattered radiation was evaluated by applying a simple calculation method based on a scattering rate concept since effect of scattered radiation is significantly important at maze entrance of the radiation facility. The calculated results obtained using the simple method were compared to the results calculated using Geant4 code and the measured values. The results calculated by the suggested method indicate that slight error exists in a radiation shielding analysis done at the maze entrance comparing to other two results, while the results evaluated at the outside of the maze entrance door are relatively consistent with other values.

무인항공체계 기반 시설물 상태점검 최근 연구동향 분석 (A Literature Review of Unmanned Aircraft System (UAS) Integrated Constructed Facility Condition Inspections)

  • 권진혁;윤지영;윤종영;이동훈;김성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.172-173
    • /
    • 2021
  • In recent, unmanned Aircraft Systems (UAS) have been widely used for various purposes, such as safety inspection, facility condition inspection, progress monitoring, in the architecture engineering, and construction (AEC) industry. This technology can provide visual assets regarding the conditions of construction jobsites as well as constructed facilities during flying over the point of interests. With the significant interests in this advancement, the recent studies have presented how the UAS can be applied fro different types of facilities (e.g., buildings, power genereation systems, roads, or bridges) to inspect the current conditions of them for safe operations as well as public's safety. This study reviewed the receent studies to document their scientific findings and practical contributions, as well as provided the overview of further implications for future studies.

  • PDF

반도체 산업설비의 사고시 사업장외에 미치는 영향평가 (Offsite Risk Assessment of Incidents in a Semiconductor Facility)

  • 윤여홍;박교식;김태옥;신동민
    • 한국위험물학회지
    • /
    • 제3권1호
    • /
    • pp.59-64
    • /
    • 2015
  • Semiconductor industry has large number of chemical inventory and is easily exposed to chemical release incidents. Toxic release is one of the most interested area in evaluating consequence to the vicinity of industry facilities handling hazardous materials. Hydrofluoric acid is one of the typical chemical used in semiconductor facility and is selected and toxic release is evaluated to assess the risk impacted to its off-site. Accident scenarios were listed using process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling hydroflooric acid is safe enough and needed no further protections at the moment.

태양광발전설비 DC 아크특성 분석 (DC Arc Characteristics Analysis according to U1699B Test Standardof the Status)

  • 김완수;박광묵
    • Current Photovoltaic Research
    • /
    • 제11권4호
    • /
    • pp.118-123
    • /
    • 2023
  • The main cause of solar facility fires is arc, and in the last 3 years ('16 to '18), about 80% of domestic solar facility fires have been caused by arcs. The capacity of solar power facilities installed around the world continues to increase, and fires caused by arcs are also expected to increase as the solar power generation facilities that were initially installed become obsolete, In this paper, an arc generation test was conducted based on the UL1699B test standard. As a result of the test, the arc generation satisfied the minimum arc current according to the test conditions, and DC arc characteristics were analyzed through data such as arc voltage and arc current according to variables such as speed of moving electrodes and electrode spacing.

중·저준위 방사성폐기물 처분시설의 운영 중 사고에 대한 평가체계 개선 : 한국의 중·저준위 방사성폐기물 표층처분시설의 운영 중 안전성평가 적용사례 (Improvement of Safety Approach for Accidents During Operation of LILW Disposal Facility : Application for Operational Safety Assessment of the Near-surface LILW Disposal Facility in Korea)

  • 김현주;김민성;박진백
    • 방사성폐기물학회지
    • /
    • 제15권2호
    • /
    • pp.161-172
    • /
    • 2017
  • 중 저준위 방사성폐기물 처분시설의 운영 중 사고로 인한 방사선적 영향을 평가하기 위해서는 운영 중 발생 가능한 사고에 대한 타당성이 입증되어야 한다. 본 논문에서는 처분시설의 운영 중 사고분석 체계를 처분시설의 구성요소에 대한 안전기능분석, 잠재위험요소분석, 위험도분석, 그리고 향후 조치대안으로 사고평가체계를 개선하였다. 이를 위하여 위험도분석에 필요한 설계대안과 관리대안을 추가하여 설계-운영-평가가 연계되도록 하였다. 또한 운영 중 사고의 발생확률과 평가결과의 심각성에 따라 운영중 사고에 대한 분류기준을 제안하여 처분시설 운영 중 대표 사고시나리오에 대한 정당성을 확보하였다. 본 논문의 개선된 평가체계를 우리나라의 2단계 중 저준위 방사성폐기물 표층처분시설에 대한 처분시설 운영 중 사고분석의 사례에 대해 적용하였다.

5G 디지털 트윈 기반 시설물 안전관리 통합플랫폼 계획 수립 절차에 관한 연구 : 수도권 광역시 시설물을 중심으로 (A Study on the Procedure for Establishing an Integrated Platform Plan for Safety Management of 5G Digital Twin-Based Facilities: Focusing on Facilities in Metropolitan Cities)

  • 장혜정
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권4호
    • /
    • pp.257-268
    • /
    • 2021
  • 도시중심의 생활로 시설물의 종류가 늘고 규모가 증가함에 따라 도시의 시설물 안전관리 사각지대가 발생하고 다수의 인명피해가 연이어 발생하고 있다. 이에 스마트 시티에서 생활하는 시민들의 안전과 안심에 대한 니즈를 충족하는 방안으로 5G와 디지털 트윈 기술을 접목하여 시설물 안전관리 통합플랫폼 수립 절차를 제시하고 이를 통하여 시설물에 대한 위험 요소와 노후화에 따른 점검의 문제점을 해결하고자 한다. 본 논문에서는 시설관리의 현황과 5G 디지털 트윈 기반의 스마트 시티 신기술 적용 방향에 대해 살펴보고 디지털 트윈으로 구현하기 위한 추진 절차를 제시한다. 대상 지역은 수도권 광역도시 지역으로 안양시, 의정부시, 구리시, 광명시, 오산시 5개 도시를 선정하였다. 추진 절차는 각 지자체의 다중이용 목적 시설물 중에서 노후화되고 관리가 시급한 시설물을 플랫폼 구축 전문가와 지자체 스마트시티 담당자와 선정한 뒤 시별 정책 방향을 반영하여 디지털 트윈 시설물 대상 33개를 최종 선정하였다. 이렇게 확정된 시별 시설물을 중심으로 5G 디지털 트윈 시설물 안전관리 통합플랫폼으로 구축하기 위한 정보기술 인프라 요소와 구현 서비스의 카테고리를 정의한 뒤 구체적인 통합플랫폼 구성안을 제시하고자 한다.