• Title/Summary/Keyword: Facility Design

Search Result 2,682, Processing Time 0.029 seconds

Effects of Coastal Environment by Discharge from the Sewage Treatment Plant (해안방류된 하수처리수가 해양환경에 미치는 영향)

  • Shin, Bumshick;Kim, Kyu-Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.127-133
    • /
    • 2020
  • Most sewage treatment plants located offshore are discharged to the shore either directly or through rivers. Therefore, the water quality of the treated water discharged from the sewage treatment plant affects the water quality of the river water discharged to the river and the ocean. In this study, field surveys and numerical simulations were conducted to investigate the effect of treated water from the sewage treatment plant adjacent to the coastal environment. As a result of analyzing the water quality and sediment quality with the samples collected from the river and the estuary where the treated water was discharged to understand the impact on the coast, the treated water discharged from the sewage treatment plant was discharged to the river without exceeding the design criteria. However, the water quality discharged to the shore through estuaries was more contaminated than treated water. The cause of water quality deterioration of coastal effluent is due to the sedimentation of estuary temporarily by longshore sediment sransport which appeared around the estuary, the occurrence of estuary obstruction, and the increase of stagnant time in the estuary. As it was released and discharged, it was analyzed to affect the water quality, water quality and marine life around the estuary. Therefore, in the case of the east coast where the longshore sediment transport is strong, when planning the sewage treatment facility discharged to the ocean, it is necessary to closely examine the water quality change of the river water in the treated water such as the river mouth occlusion by the longshore sediment transport.

Evaluation of Applicability of Apparent Track Stiffness Measured by Light-Weight Deflectometer as a Ballasted Track Condition Index (소형동평판재하시험기로 측정한 궤도 겉보기 강성의 자갈궤도 상태평가 지표로서의 적용성 고찰)

  • Choi, Yeong-Tae;Hwang, Sung Ho;Jang, Seung Yup;Park, Bongsik;Shim, Gwang Seop
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 2018
  • Ballasted track has been widely used due to its flexibility. However, the plastic deformation of ballasted track causes the evolution of track geometrical errors, and hence it requires continuous maintenance; increase in number of trains, weight, and speed expedites maintenance frequency and cost as well. Ballast stiffness is well-known as an indicator of design and maintenance. In this regard, this paper aims to suggest the method to measure ballast track stiffness using light-weight deflectometer (LWD) and thus verify its applicability as a maintenance measure. Preliminary field tests determined simple field testing protocol to measure track stiffness. The apparent ballast stiffness by LWD shows good corelation with TQI (Track Quality Index) and maintenance length. That is, as average of apparent stiffness increase, TQI and tamping length decrease exponentially. Therefore, apparent stiffness can be used as an index for ballast condition assessment.

The Study of Comparison Satisfaction and Re-use Intention between Central and Ward Reception Desk Users (입.퇴원 수속창구 중앙화와 분산화에 따른 이용자의 만족도와 재이용 의사)

  • Ham, Tae-Hoon;Lee, Kyung-Woo;Sohn, Tae-Yong;Yu, Seung-Hum
    • Korea Journal of Hospital Management
    • /
    • v.14 no.4
    • /
    • pp.149-162
    • /
    • 2009
  • The purpose of this study is to design strategic hospital service based on each hospital's features. For this study, an assessment was conducted by 398 in-patents of one university hospital located in Seoul. The self-questionnaires, which were investigated from Oct. 15th to 29th in 2008, compared central reception desk with ward reception desk in satisfaction and re-use rate of patients. The major results of this study are as follow. First, according to each reception desk user, they have different satisfaction of it. As for the staff kindness, admission procedure, discharge procedure and manner of staff, those made patients be gratified as well. Second, when it comes to the intention of re-use, there were no significant features between them. Only convenience in admission and discharge procedure, however, was an attractive factor for the recommendation. Third, this study found out the reasons for higher re-use rate of central reception desk users. Regarding service, they were contented with the time for test and treatment. As for the hospital service, they would like to re-use this hospital because of convenient steps of paying interim fee and getting certificates. Forth, this study found out the reasons for higher re-use rate of ward reception desk users. As a point of hospital service view, they responded that respected privacy, hospital facility and general service were good for staying. As for the manner of staff, they mentioned nurses and staff in charge and whole staff members were kind. When it comes to the procedures of patient management, steps of discharge and paying interim fee were convenience. In conclusion, the results of this study suggest that providing a ward reception desk service can boost the satisfaction and re-use rate of in-patients. Furthermore, this strategic management method would be good for not only cutting the moving line but also efficient in-patient care system. These results can be used for the strategic hospital marketing field, as well. Even though this study has a limitation of the targeted populations which were only in a ward reception desk running hospital, it can say that having competitiveness in satisfaction of hospital service is good for promoting and differencing each hospital. Consequently, whole general management system would be adjusted first for differencing each hospital; however, this sort of additional factor should be concerned as well. I expect that this study would give meaningful data for designing strategic and differencing marketing method to lots of hospitals.

  • PDF

An Analysis of the Duration of the Construction Document Phase of Large Public Building Projects Delivered by the Total Solution Service from 2009 to 2014 (공공기관 발주 대형건축공사 실시설계 기간에 대한 분석 및 개선방안 -2009년부터 2014년까지 공공발주 맞춤형 서비스 프로젝트를 중심으로 -)

  • Jung, Wooyoung;Lee, Taewon;Rhee, Pung-wook;Lee, Ghang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.4
    • /
    • pp.89-97
    • /
    • 2015
  • This paper analyzes the duration of the construction document (CD) phase of 42 large public building projects delivered by the total solution service of Public Procurement Services in Korea from 2009 to 2014. The quality of construction documents significantly affects the quality of construction and facility management. Thus, securing appropriate time for the CD phase during project planning is important for the quality of a project. Currently, the duration of the CD phase is planned based on the construction costs of a project following a notice of the Ministry of Land, Infrastructure and Transport. However, our analysis results showed that the correlation between the actual duration of the CD phase and construction costs is very weak. The actual CD phase takes 1.33-1.79 times longer than the planned duration. The practitioners who were interviewed, were already aware that the correlation between the duration of the CD phase and the construction costs is weak. They identified the complexity of the project, the extent of the design changes, project type, client characteristics, and others as more influential factors on the CD phase than the construction costs. To improve the quality of CDs, a new guideline for determining an adequate CD phase duration should be studied and developed.

Suitability for Subgrade Material of Weathered Granite Soils in the Gansung area of Gangwon-do (강원도 간성지역에 분포하는 화강풍화토의 도로토공 재료특성 연구)

  • Jeoung, Jae-Hyeung;Yu, Jun;Kim, Jin-Man;Kim, Seung-Hyun;Lim, Kwang-Su
    • The Journal of Engineering Geology
    • /
    • v.21 no.3
    • /
    • pp.239-246
    • /
    • 2011
  • Upon encountering weathering soil at a construction site, it may be necessary to change the design and construction plans for geotechnical structures. When weathering soil is exposed to air, the weathering process proceeds rapidly, resulting in significant damage to geotechnical structures, particle defects, and an increase in moisture sensitivity. The management of weathering-soil compaction is challenging. Because the engineering properties of weathering-soils vary regionally, it is important to report the result of research into the regional characteristics of such soils. At two locations of granite gneiss in the Gansung area of Gangwon-do, geological studies were performed at 22 and 8 sites, respectively. At each site, test samples were collected for analysis by XRD and to measure particle size, consistency, and compaction. To evaluate the suitability of the material for road subgrade, we examined the interrelationship between CBR value and the uniformity coefficient, the 200 sieve passing ratio and the aggregate ${\geq}$ 2 mm) content. We found that for the weathered granite soil, aggregate sized > 2 mm has a significant effect on the CBR value. In addition, the mixing of aggregate sized > 2 mm with sub-quality soil improves the soil condition.

The Technology Development Trends of Supercritical CO2 Power Generation (초임계 CO2 발전 기술개발 동향)

  • Kim, Beom-Ju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.531-536
    • /
    • 2016
  • The worldwide research and development for high-efficiency power generation system is progressing steadily because of the growing demand for reducing greenhouse gas emissions. Many countries have spurred the research and development of supercritical $CO_2$ power generation technology since 2000 because it has the advantage of compactness, efficiency, and diversity. Supercritical $CO_2$ power generation system can be classified into an indirect heating type and a direct heating type. As of now, most studies have concentrated on the development of indirect type supercritical $CO_2$ power generation system. In the United States, NREL(National Renewable Energy Lab.) is developing supercritical $CO_2$ power generation system for Concentrating Solar Power. In addition, U.S. DOE(Department of Energy) also plans to start investing in the development of the supercritical $CO_2$ power generation system for coal-fired thermal power plant this year. GE is developing not only 10MW supercritical $CO_2$ power generation turbomachinery but also the conceptual design of 50MW and 450MW supercritical $CO_2$ power generation turbomachinery. In Korea, the Korean Atomic Energy Research Institute has constructed the supercritical $CO_2$ power generation test facility. Moreover, KEPRI(Korea Electric Power Research Institute) is developing a 2MW-class supercritical $CO_2$ power generation system using diesel and gas engine waste heat with Hyundai Heavy Industries.

Evaluation of Uplift Force Acting on Foundation of Underground Structure (지하구조물 하부에 작용하는 양압력 평가)

  • Kim, Jin-Man;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.662-671
    • /
    • 2020
  • The uplift force acts directly on the foundation and causes a building to float to the upper ground. To examine the stability of a structure according to the uplift force, four sites (Paju, Anyang, Osan, and Gangneung) were selected, and sensors were installed on the foundations for the field tests. The rainfall characteristics were analyzed around June~September, and the changes in the water level of the adjacent river were considered. The maximum uplift force except for Gangneung did not exceed 72% of the water pressure when the groundwater level was up to the surface. On the other hand, the maximum uplift force in Osan was approximately 67%, but the reliability was slightly inferior because the difference from the average (46%) was large. The minimum uplift force was within 10% except for Anyang (~ 41%). At the Gangneung site on soft rock where the permanent drainage facility was installed before the measurement, the maximum and minimum uplift force was approximately 14% and 3.5%, respectively. Based on the measurement results, the possibility of overdesigning or underdesigning comes from the design by the hydrostatic pressure when the groundwater level is up to the surface.

An Investigation of Road Crossing Behaviour of Older Pedestrians at Unsignalized Crosswalk (무신호 단일로 횡단보도에서 고령 보행자의 횡단행태조사 및 분석)

  • JANG, Jeong Ah;KIM, Junghwa;CHOI, Keechoo
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.3
    • /
    • pp.207-221
    • /
    • 2016
  • In Korea, older pedestrian accounted for 57% of all pedestrian deaths although a ratio of older pedestrian accidents to total pedestrian accidents was only 25.9%. Though ageing population problem becomes more challenging for road safety, little is know about the behaviour of older pedestrian's behaviour. This study aimed to identify road crossing behaviour of older pedestrian at three-lane unsignalized crosswalks using video image analysis and to compare the behaviour of older pedestrian to younger one by indicators including approaching speed, the number of walking steps and other factors. The results showed that there was a difference of approaching time at kerb, waiting time at kerb, the number of glances at kerb, and the number of glances at crossing between two groups under the situation of car approaching to crosswalks. It also showed that older pedestrian usually spent 1.16 times more than younger pedestrian to walk across the crosswalk with only 84.4% of walking speed of younger pedestrian. The number of steps of older pedestrian for road crossing was 1.12 times higher with 90% shorter steps than younger pedestrian. It was concluded that older pedestrian usually decided to walk across in case of 1.67 times longer headway than younger pedestrian's decision. These results could be applied in road and facility design for better safety of older pedestrians.

A Study on the Quantitative Process Facility Standards that Require H2S Toxic Gas Detectors and Location Selection for Emergency Safety (H2S 독성가스감지기가 필요한 정량적 공정설비 기준 및 비상시 안전을 위한 위치선정 방안에 대한 연구)

  • Choi, Jae-Young;Kwon, Jung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.90-96
    • /
    • 2018
  • Design techniques for minimizing the damage caused by leakage of $H_2S$ gas, contained in natural gas and petroleum, have been widely studied abroad in chemical plants that purify and process natural gas and petroleum. However, there is no domestic engineering practice and regulation of $H_2S$. In accordance with the circumstances, this study proposes the quantitative criteria of process equipment to install $H_2S$ toxic gas detector as 500 ppm and explains the valid basis. The $H_2S$ gas dispersion radius up to IDLH 100 ppm is calculated by ALOHA under previous $H_2S$ gas leak accident scenario. The weather conditions of modeling include the conditions of Ulsan, Yeosu and Daesan, the three major petrochemical complexes in Korea. The long radius up to 100 ppm was derived in order of Ulsan, Daesan, Yeosu. For emergency safety the dispersion radius up to 100 ppm of the $H_2S$ gas obtained in this study should be extended to apply the additional $H_2S$ toxic gas detector, and local climate conditions should be considered.

Operation Method of Power Supply System for Eco-friendly Movable-weir Based on Natural Energy Sources (자연에너지를 이용한 친환경 가동보용 전원공급시스템의 운용방안)

  • Kwon, Pil-June;Lee, Hu-Dong;Tae, Dong-Hyun;Park, Ji-Hyun;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.601-610
    • /
    • 2020
  • Recently, damage caused by drought is becoming worse and worse due to the global climate change. To overcome these problems, movable-weir to control the water level has been installed instead of a fixed-weir made from concrete. On the other hand, it is difficult to operate an existing moveable-weir because of the high cost of facility management and manpower consumption. In addition, because most moveable-weirs are installed in power systems, the operating cost and the cost of connection for power systems increase when they are located in remote areas. Therefore, this paper proposes an optimal design algorithm and the evaluation algorithm of the SOC (state of charge) of a lithium-ion battery to replace an existing power supply with eco-friendly movable-power with a power supply system using PV modules and lithium-ion batteries. In addition, this study modeled a 50kW power supply system of a movable-weir using PSCAD/EMTDC S/W. The simulation results confirmed that the proposed algorithm has stable operation characteristics in an independent operation mode and interconnection operation mode and that there is the possibility of commercialization with a benefits evaluation of the eco-friendly power supply system of a movable-weir.