• Title/Summary/Keyword: Facility Design

Search Result 2,682, Processing Time 0.037 seconds

A Design of PWR Hydraulic Test Facility at KAERI

  • Oh, Dong-Seok;Shin, Chang-Whan;In, Wang-Kee;Chun, Tae-Hyun;Jung, Yeun-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.13-14
    • /
    • 2005
  • KAERI is performing a project on out-pile test technology development for a full scale PWR fuel assembly. We have introduced the hydraulic test facility, a test assembly, test parameters, test methods, and a data acquisition system. The start up test will be in the middle of March 2005 and the main test will be accomplished by the end of 2006. The established test facility and measuring technique will contribute to the satisfaction of domestic needs for the design verification to improve the reliability of a PWR plant operation.

  • PDF

Aircraft Engine Performance Test Technologies by 150K lbf Thrust Test Cell (15만 파운드급 테스트 셀을 이용한 엔진성능 시험기술)

  • Kim, Woocheol;Kim, Chul;Kim, Sangbaek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.180-187
    • /
    • 2017
  • Major design targets such as test cell type, cell flow, cell bypass ratio, approach velocity, cell depression, front cell distortion, noise level and vibration level to construct a new 150,000 lbf thrust aircraft engine test facility were established. Based on the final aerodynamic and acoustic performance tests conducted at the newly constructed test facility, it was found that the new test facility is judged to be excellent and meets design targets.

  • PDF

UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower (UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계)

  • Lee, Dong-Cheol;Bae, Ul-Lok;Kim, Woo-Jung;Min, Bung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

A Study on the Architectural Planning of the Hospital for the Elderly with Dementia (치매노인전문병원의 건축계획에 관한 연구)

  • Lee, Jung Min;Yu, Young Min
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 2001
  • Facing the aging society in Korea, the necessity of the facility for the elderly is arising as a substitute to cut down the cost and to provide suitable and skillful medical services for the aged and chronical. Among there, health care facilities for the elderly with dementia are considered a essential facility. Therefore, it is necessary to prepare the guidelines for planning and design of the facility. On the bases of survey and analysis, the basic data for planning and design the hospital for the elderly with dementia has been proposed.

  • PDF

Purification of Stream Water Quality by Subsurface-flow Wetland Facility (습지여상시설을 이용한 하천 수질정화)

  • Jung, Yong-Jun;Lim, Ki-Sung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.456-461
    • /
    • 2006
  • The facility of constructed wet land combined with filter media was examined in order to improve the water quality of a polluted stream, which has been performed as a part of national projects. Throughout 2 years of operation for a stream, it can provide the design and operating parameters for the purpose of future construction. The influent flow rate was about 50% against the design capacity. The removal efficiencies of BOD, $COD_{Mn}$, SS, T-N and T-P were 62.9%, 47.1%, 74.8%, 22.4% and 33.5%, respectively. In order to keep this facility stable, the removal of surface filter media and supplement should be periodically conducted. In addition, the proper selection of sites is recommended not to be flooded.

Design of High-Frequency Data Acquisition System for Combustor Combustion Test Facility (연소기 연소시험설비 고주파 계측 시스템 설계)

  • Ahn, Kyu-Bok;Kang, Dong-Hyuk;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.461-464
    • /
    • 2012
  • The high-frequency data acquisition system of the rocket engine test facility has been updated to perform hot-firing tests of 7 ton-class liquid rocket engine combustion chambers which will be used for the third stage of the Korea space launch vehicle II. The paper deals with the design of the updated high-frequency data acquisition system and explains its main functions.

  • PDF

Similarity evaluation of the pump simulation loop in STELLA-2 for conservation of mechanical sodium pump characteristics

  • Jung Yoon ;Jewhan Lee ;Jaehyuk Eoh;Hyungmo Kim ;Dong Eok Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.353-363
    • /
    • 2023
  • The STELLA-2 is a large-scale sodium thermal-hydraulic integral effect test facility and supports the development of PGSFR. The facility adopted Pump Simulation Loop System (PSLS) concept for the mechanical sodium pump in the reference reactor to control and to measure the primary sodium flow. Since the component (mechanical pump) is replaced by the loop, it is very important to evaluate the similarity between the pump and the loop. In this paper, to simulate the characteristic of the mechanical sodium pump, the pressure loss along the various options of the loop was evaluated and the comprehensive validity of each design options was analyzed. Using the similarity criteria based on the Richardson number and Euler number conservation, the PSLS design was finalized and the result was within the acceptable error range. Finally, the result of this study was used for construction of the overall facility, STELLA-2.

A Study on the Fire Design Business Development Direction (소방시설설계업의 발전방향에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae;Park, Hung-Joo
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 2009
  • For the fire-fighting industry to advance, it is necessary to conduct research on which parts of the fire-fighting law should be changed from the system level, and to study the opinions of the fire-fighters whoa re working in the fire-fighting industry today, and to identify what needs to be changed. Moreover, it is necessary to become aware on the preventive measures to take to avoid fire so that the citizens can lead stable life. Design business among the fire-fighting facility business, it is the fire-fighting facility business that serves as the most basic when constructing building structure. This is an important legal matter that follows the fire-fighting business, fire-fighting audit business and even the maintenance and management business. This research sought to help the fire-fighting industry to contribute to the life of the general public and to increase welfare by identifying the problems pertaining to the fire-fighting facility design business among the fire-fighting industry so that the industry can become the fire-fighting industry that the citizens are interested in. Moreover, direction for advancement is proposed. As for the improvement measures for the fire-fighting policy pertaining to the fire-fighting facility design business, it is divided into the machinery and electricity fields in terms of the legal system pertaining to the general fire-fighting facility design business. Likewise, specialty in design is deficient. Thus, it should be integrated in a systematic level to contribute to the safety of the general public.

The Review of Design and Installation of the Thermal Relief Valve with It's Surrounding Facility in a Chemical Plant Piping System (배관계에서 열팽창을 고려한 열팽창매출변 및 주변설비의 설계와 설치에 관한 고찰)

  • 차순철;김영배
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.3
    • /
    • pp.104-114
    • /
    • 1997
  • Throughout the practical process engineering design and commissioning 8E startup experiences focused on chemical process safety, the review of design and installation of the thermal relief valve with its surrounding facility in a chemical plant piping system is made to help the better understanding of the piping system of characteristics of thermal relief valve which Is consisting of theoretical approach, correlation in terms of temperature and pressure increase caused by external heat supply in a piping system, consideration of thermal relief valve design, pressure relieving system of serial thermal relief valves and exception of their installation. It is earnestly recommended that following topic should be implemented during thermal relief valve design, installation and normal operation as well.

  • PDF