• Title/Summary/Keyword: Facility Design

Search Result 2,682, Processing Time 0.031 seconds

Specific Process Conditions for Non-Hazardous Classification of Hydrogen Handling Facilities

  • Choi, Jae-Young;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.416-420
    • /
    • 2021
  • Hazardous area classification design is required to reduce the explosion risk in process plants. Among the international design guidelines, only IEC 60079-10-1 proposes a new type of zone, namely zone 2 NE, to prevent explosion hazards. We studied how to meet the zone 2 NE grade for a facility handling hydrogen gas, which is considered as most dangerous among explosive gases. Zone 2 NE can be achieved considering the grade of release, as well as the availability and effectiveness of ventilation, which are factors indicative of the facility condition and its surroundings. In the present study, we demonstrate that zone 2 NE can be achieved when the degree of ventilation is high by accessing temperature, pressure, and size of leak hole. The release characteristic can be derived by substituting the process condition of the hydrogen gas facility. The equations are summarized considering relation of the operating temperature, operating pressure, and size of leak hole. Through this relationship, the non-hazardous condition can be realized from the perspective of inherent safety by the combination of each parameter before the initial design of the hydrogen gas facility.

A Conceptual Design Study for a Spent Fuel Pyroprocessing Facility of a Demonstration Scale (사용후핵연료 파이로 처리공정 실증시설의 개념설계 연구)

  • Yoo, Jae-Hyung;Hong, Kwon-Pyo;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.233-244
    • /
    • 2008
  • A conceptual design study for a pyroprocesing facility, has been carried out in this study, which is available for the recovery of uranium and transuranic elemental group(TRU), that is, reusable as a nuclear fuel especially in a next generation-type reactor. The scale of this facility has been chosen as 20 kg HM/batch, comparatively small engineering size in order to collect scale-up data for the design of a commercial facility as well as to get operational experience. The spent fuel to be handled in this process is as follows : 3.5 % enriched uranium fuel, 35,000MWd/tU and 5-year cooled. The major items considered in the conceptual study are a building lay-out including various hot cells, safety management of the process operation in conjunction with material balance control, radiation safety, inert atmosphere control in shielded hot cells, and criticality control of uranium and TRU products.

  • PDF

Estimation of Stormwater Interception Rate for Bio-retention LID Facility (생태저류지 LID 시설의 강우유출수 처리비 산정)

  • Choi, Jeonghyeon;Lee, Okjeong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.563-571
    • /
    • 2017
  • Because of the rapid progress of urbanization in recent decades, the proportion of impervious areas in cities has increased. As a result, hydrological properties of urban streams have changed and non-point pollution sources have increased, that have had considerable influence on human life and ecosystems. To manage these situations, application of non-point pollution reduction facilities and LID facilities are expanding recently. In this study, it is investigated if rainfall interception rate used in design of non-point pollution reduction facilities can be applied to design of LID facilities. For this purpose, EPA SWMM is constructed for part of Noksan National Industrial Complex area wherein long-term observed storm water data can be obtained and storm water interception rates for various design capacities of a bio-retention LID facility reservoirs are estimated. While sensitivity of storm water interception rate according to design specifications of bio-retention facility is not large, sensitivity of storm water interception rate according to regional rainfall characteristics is relatively large. As a result of comparing present rainfall interception rate estimation method with the one proposed in this study, the present method is highly likely to overestimate performance of the bio-retention facility. Finally, a new storm water interception rate formula for bio-retention LID facility is proposed.

Analysis of Earthquake Countermeasure for Electrical Facility Building on Domestic and Foreign (국내외 건축물에 시설되는 수변전설비 지진 대책에 관한 조사 분석)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.150-156
    • /
    • 2008
  • Recently life and properties damage at Japan and China by generating earthquake. For establishing measure for earthquake in domestic, earthquake disaster measure law was enacted on March, 2008 from a natural disaster of earthquake and present the detail part and enforce the measures. This paper analyzes domestic site and problems of electrical facility earthquake measures at transformer vault which the power supply the emergence situation at generating earthquake. Also we present the domestic seismic design and construction direction from research and analysis related law and regulation for the seismic design and construction in domestic and foreign for electrical facility. Afterward we will need to study reliability inspection for electrical facility seismic design method and construction at buildings transformer vault.

A study on optimal of block facility layout using Hybrid GA (Hybrid GA를 이용한 최적의 블록단위 설비배치에 관한 연구)

  • 이용욱;석상문;이철영
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.131-142
    • /
    • 2000
  • Facility layout is the early stage of system design that requires a mid-term or long-term plan. Since improper facility layout might incur substantial logistics cost including material handling and re-installment costs, due consideration must be given to decisions on facility layout. Facility layout is concerned with low to arrange equipment necessary for production in a given space. Its objective is to minimize the sum of all the products of each equipment's amount of flow multiplied by distance. Facility layout also is related to the issue of NP-complete, i.e., calculated amounts exponentially increase with the increase of the number of equipment. This study discusses Hybrid GA developed, as an algorithm for facility layout, to solve the above-mentioned problems. The algorithm, which is designed to efficiently place equipment, automatically produces a horizontal passageway by the block, if a designer provides the width and length of the space to be handled. In addition, this study demonstrates the validity of the Algorithm by comparing with existing algorithms that have been developed. We present a Hybrid GA approach to the facility layout problem that improves on existing work in terms of solution quality and method. Experimental results show that the proposed algorithm is able to produce better solution quality and more practical layouts than the ones obtained by applying existing algorithms.

  • PDF

Model Development of Unit-care Welfare Facility for a Traditional Korean House Using Computer Graphics (컴퓨터 그래픽을 이용한 한옥 유니트형 노인복지시설 모델 제시)

  • Nam, Yun-Cheol
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.1
    • /
    • pp.23-31
    • /
    • 2013
  • This paper presents computer graphics applying the traditional Korean house(Hanok) style interior to unit-care space of Welfare Facility and proposes the possibility as interior design and construction materials. In this paper, the proposed computer graphic-based model is a single-story building that provides convenient traffic between rooms. Computer graphic-based model is presented by Auto CAD, 3D program (Sketch-UP v.8), rendering program (Podium v.2) based on the traditional Korean house and related work of unit-care welfare facility. Computer graphic-based model that combined unit-care and the traditional Korean house has the following characteristics. In each room of living space, wallpaper and flooring Korean paper(Hnaji) is considered and windows, door, furniture of traditional pattern were placed. The living room(Daechung) that is representative of the traditional Korean house and the corridor (toenmaru) are the elements to save the image of the traditional Korean house as much as possible. Especially, the corridor (toenmaru) is placed to conveniently use in nursing-care facility and home-care support facility. A public space is placed around the inside court (An-madang), while the living space (unit-care) has a sense of independence by separation. Bathroom and kitchen have a modern design for functionality than aesthetic elements.

A Study on the Architectural Condition of Women's Hall as Social Education Facilities (사회교육시설로서 여성회관의 시설현황 연구)

  • Lim, Sun-Joo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.5 no.1
    • /
    • pp.40-53
    • /
    • 2006
  • Recently, women's social activities in our society have been greatly increased and legal system and mechanism of social structure to pursue a society where gender equality shall be realized has been discussed lively in a detail manner. Nevertheless, the rate of social advancement of Korean women shows much lower than that of the western industrialized countries. The aim of this study is to examine such problem and to look for a solution thereof. As the subject for this survey, such social welfare facility as women's hall was selected, and then its state of facilities was investigated. The results from this survey revealed that women's hall, which had been started constructing since 1950s, began to spread out nationwide reaching the 1990s, and that women's hall was greatly used as a major public facility that supports women's social activities in each region, and that women's hall, which had been started as a social welfare facility, was a multifunctional facility performing functions such as welfare, education, culture and community, and that educational function among these had been changed a little by little in the aspect of contents and purpose according to the changes of times, however, education for women was treated as a major important function in the women's hall and operated accordingly.

  • PDF

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

A Study on Development and Analysis of Accident Influence Factor Verification Tools for the Elderly People in the Welfare Facilities for the Aged (노인주거 복지시설 거주 노인의 안전사고 영향변수 검증도구 개발 및 분석에 관한 연구)

  • You, Jong-Ok;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.242-248
    • /
    • 2011
  • According to a study on the accident patterns of older people in 2006 by Korea Consumer Agency (CISS), the number of accidents of the elderly at home reached 486, and the figure has increased every year. As Korea is about to enter into the aged society, it is important to investigate the factors that cause an accident in the welfare facilities for the aged and establish the barrier-free construction standards. The accident influence factors include facility environmental, physical functional, socio demographic and socio psychological factors. In terms of the verification tools, there are Facility Evaluation Index, FIM, MMSE-K and General Feature. In terms of analysis method, in addition, there are real number, percentage, t-test, ANOVA and logistic regression. In conclusion, this paper attempts to reveal correlations among the accident influence factors using the Facility Evaluation Standards (115 items in total) for facility environmental factor, FIM (3 items) for physical functional factor, MMSE-K (6 items) for socio psychological factor and questionnaire (5 items) for socio demographic factor.