• Title/Summary/Keyword: Facility Condition Assessment

Search Result 66, Processing Time 0.023 seconds

Study of Mobility for Radionuclides in Nuclear Facility Sites (원자력 시설물 주변에서의 방사성 오염물 거동 특성 연구)

  • Chang, Seeun;Park, JongKul;Um, Wooyong
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.99-111
    • /
    • 2018
  • In this study three target radionuclides ($^{60}Co$, $^{137}Cs$, and $^{125}Sb$) were reacted with solid samples collected from the nuclear facility sites to investigate their sorption and mobility behaviors for preparing unexpected nuclear accidents. The highest sorption distribution coefficients ($K_{ds}$) of target radionuclides ($^{60}Co=947mL/g$, $^{137}Cs=2105mL/g$, $^{125}Sb=81.3mL/g$) were found in topsoil layer under groundwater condition, and the $K_d$ values of three radionuclides decreased in the order of fractured rock and bedrock samples under the same groundwater condition. High $K_d$ values of $^{60}Co$ in topsoil layer and fracture rock resulted from the clay minerals present, and the $K_d$ values decreased 58-69 % under seawater condition due to high ionic strength. $^{137}Cs$ sorption was controlled by the ion exchange reaction with $K^+$ on flayed edge sites (FES) of mica. The $^{137}Cs$ sorption was the most affected by seawater (89-97 % decrease), while $^{125}Sb$ sorption was not much affected by seawater. As the results of column and batch experiments, the retardation factors (R) of $^{137}Cs$, $^{60}Co$, and $^{125}Sb$ were determined about 5400-7400, 2000-2500, and 250-415, respectively, indicating no significant transport for these radionuclides even in fractured zone with groundwater. These results suggest that even in the case of severe nuclear accident at the nuclear facilities the mobility of released radionuclides ($^{60}Co$, $^{137}Cs$, and $^{125}Sb$) can be significantly retarded by the topsoil layer and fractured rock. In addition, the results of this study will be used for the safety and environmental performance assessment of nuclear facilities.

Leachate Treatment using Intermittently Aerated BAC-Fluidizing Bed (간헐폭기 생물활성탄 유동상에 의한 매립지침출수 처리)

  • Kim, Kyu Yeon;Lee, Dong Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.4
    • /
    • pp.136-147
    • /
    • 2005
  • Leachate from landfill sites contains high organics, chloride and ammonium nitrogen in concentration which might be potentially major pollutants to surface and groundwater environment. Most of landfill leachate treatment plants in Korea consist of biological processes to remove BOD and nitrogen. However, the efficiencies of refractory organics removal, nitrification and denitrification have not met frequently the national effluent regulation of wastewater treatment facility, especially in winter season. Simultaneous removal of organics and nitrogen from leachate is strongly necessitated to meet the national regulation on effluents from leachate treatment facilities. The intermittently aerated biological activated carbon fluidized bed(IABACFB) process was applied to treat real landfill leachates containing refractory organics and high concentration of ammonium nitrogen. The IABACFB reactor consisted of a single bed in which BAC fluidizing and an aerating column. The fluidized bed is intermittently aerated through the blower located at the aerating column. Experiments were performed to evaluate the applicability of Intermittently Aerated BACFB for simultaneous removal of refractory organic carbon and ammonium nitrogen of leachate. Organics and ammonia nitrogen($NH{_4}{^+}-N$)are oxidized during the aerobic stage, and nitrite-nitrate nitrogen($NO{_x}{^-}-N$) are removed to nitrogen gas through denitrification reaction during anoxic state. The IABACFB reactor condition reached a steady state within 40 days since the reactors had been operated. The blowing mode of 60 min.-On/60 min.-OFF is more compatible to remove TOC and ($NH{_4}{^+}-N$) operated. The blowing mode of 60 min.-On/60 min.-OFF is more compatible to remove TOC and ($NH{_4}{^+}-N$) simultaneously than the mode of 30 min.-On/90 min.-OFF. The average removal efficiencies of TOC, the refractory organic carbon, and the average efficiencies of nitrification and denitrification were 90%, 75%, 80%, 95%, respectively.

  • PDF

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

Assessment of the Structural Collapse Behavior of Between Offshore Supply Vessel and Leg in the Jack-up Drilling Rig (잭업드릴링 리그의 레그와 작업 지원선 충돌에 의한 구조붕괴 거동 평가)

  • Park, Joo-Shin;Seo, Jung-Kwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.601-609
    • /
    • 2022
  • Jack-up drilling rigs are mobile offshore platforms widely used in the offshore oil and gas exploration industry. These are independent, three-legged, self-elevating units with a cantilevered drilling facility for drilling and production. A typical jack-up rig includes a triangular hull, a tower derrick, a cantilever, a jackcase, living quarters and legs which comprise three-chord, open-truss, X-braced structure with a spudcan. Generally, jack-up rigs can only operate in water depths ranging from 130m to 170m. Recently, there has been an increasing demand for jack-up rigs for operating at deeper water levels and harsher environmental conditions such as waves, currents and wind loads. All static and dynamic loads are supported through legs in the jack-up mode. The most important issue by society is to secure the safety of the leg structure against collision that causes large instantaneous impact energy. In this study, nonlinear FE -analysis and verification of the requirement against collision for 35MJ recommended by DNV was performed using LS-Dyna software. The colliding ship used a 7,500ton of shore supply vessel, and five scenarios of collisions were selected. From the results, all conditions do not satisfy the class requirement of 35MJ. The loading conditions associated with chord collision are reasonable collision energy of 15M and brace collisions are 6MJ. Therefore, it can be confirmed that the identical collision criteria by DNV need to be modified based on collision scenarios and colliding members.

Influence of Mixture Non-uniformity on Methane Explosion Characteristics in a Horizontal Duct (수평 배관의 메탄 폭발특성에 있어서 불균일성 혼합기의 영향)

  • Ou-Sup Han;Yi-Rac Choi;HyeongHk Kim;JinHo Lim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.27-35
    • /
    • 2024
  • Fuel gases such as methane and propane are used in explosion hazardous area of domestic plants and can form non-uniform mixtures with the influence of process conditions due to leakage. The fire-explosion risk assessment using literature data measured under uniform mixtures, damage prediction can be obtained the different results from actual explosion accidents by gas leaks. An explosion characteristics such as explosion pressure and flame velocity of non-uniform gas mixtures with concentration change similar to that of facility leak were examined. The experiments were conducted in a closed 0.82 m long stainless steel duct with observation recorded by color high speed camera and piezo pressure sensor. Also we proposed the quantification method of non-uniform mixtures from a regression analysis model on the change of concentration difference with time in explosion duct. For the non-uniform condition of this study, the area of flame surface enlarged with increasing the concentration non-uniform in the flame propagation of methane and was similar to the wrinkled flame structure existing in a turbulent flame. The time to peak pressure of methane decreased as the non-uniform increased and the explosion pressure increased with increasing the non-uniform. The ranges of KG (Deflagration index) of methane with the concentration non-uniform were 1.30 to 1.58 [MPa·m/s] and the increase rate of KG was 17.7% in methane with changing from uniform to non-uniform.

Standards of Due Diligence and Separation of Responsibilities in the Division of Labor in Medicine (분업적 의료행위에 있어서 주의의무위반 판단기준과 그 제한규칙들)

  • Choi, Hojin
    • The Korean Society of Law and Medicine
    • /
    • v.19 no.2
    • /
    • pp.41-72
    • /
    • 2018
  • In the division of labor (or teamwork) in medicine, the responsibility of medical and nursing staff should be separated or distributed to justify negligent criminal offenses. The present work refers to the standards by which the due diligence and responsibility of the individual persons are to be determined and delimited. In this context, it has been proven that objective theory as a measure of due diligence is appropriate. From a moral point of view, when assessing due diligence, it makes sense to impose greater individual or higher performance demands on the perpetrator, but law and order require that due diligence should result from socially relevant human behavior. To give objective measure of negligence and to provide the highest level of personal responsibility, so that man can not be burdened too much responsibility and it is accordingly with an equality theorem. Afterwards some points are presented, which should be considered in a concrete fact in the determination of the medical negligence. Medical action has specific characteristics such as professionalism, discretionary and exclusive, unbalance of information. These characteristics distinguish medical actions from general negligence. The general level of knowledge, the urgency, working condition and working environment of the medical facility, duration of the professional practice, assessment of the medical activity are crucial in this context. As a standard of delineation of due diligence, I have used the permitted risk and the principle of trust. In the horizontal division of labor, the principle of trust applies. The principle of trust applies in principle in cases of division of labor interaction, when doctors in the same hospital exercise their own specific occupational field or everyone works in another hospital. However, this is not true for every case. In the vertical division of labor, the principle of trust does not apply and the senior physician can not trust the assistant doctors. In this case, the principle of trust is converted into a duty of supervision for assistant doctors by the senior physician. This supervision requirement could be used as a random check.