• 제목/요약/키워드: Facility Condition Assessment

검색결과 66건 처리시간 0.02초

BIM Application Process for Facility Condition Assessment Documentation Work

  • Yoo, Seung Eun;Yu, Jung Ho
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.268-270
    • /
    • 2015
  • Overseas countries' government and facility management industries make efforts to ensure precise and fluent data from building information modeling (BIM). In facility management, a large amount of data and information are necessary to continue the process activities. Facility condition assessment, which is performed to make budget plan for the maintenance and operation requires the related facilities' documentation and information. However, it depends on the owner and the user of the facility to provide accurate and complete information to consultant. The problems as follows: (1) owner and user should provide documents and information, and (2) the consultant cannot verify the provided information. To solve these problems, we suggest a methodology to produce the information for FCA through BIM. First, all of the essential documentation and assessment elements are listed. Next, the documents and elements are separated out, whether they are able to be extracted from BIM or not. Then, the list indicates only the data that is linked with BIM. The suggestion is expected to provide the required information through the connection to BIM with accuracy and completeness and to present another BIM application use for facility management.

  • PDF

공공 시설관리기관의 시설관리시스템 개선에 관한 연구 (An Improved Facility Management System for Public Facility Management Corporations)

  • 김창덕;이현철
    • 한국건설관리학회논문집
    • /
    • 제19권1호
    • /
    • pp.32-42
    • /
    • 2018
  • 시설 관리는 시설의 자산적 가치뿐만 아니라 시설 환경 및 사용자 성능까지도 시설 관리 수준에 의해 결정된다는 점에서 매우 중요하다. 시설 전체 생애 비용 중 운영 및 관리 비용은 시설의 용도와 사용 정도에 따라서 초기 건설비용의 3배에서 10배에 달한다. 효율적인 시설 관리는 다양한 용도로 건설된 다수의 시설을 관리하는 공공 시설관리 기관의 경우 더욱 중요하며, 특히 제한된 자원(인력/장비 등)과 제한된 예산으로 다양한 사용자를 위한 다양한 시설을 관리할 때 이 중요성은 증폭된다. 본 연구는 전국에 있는 16개의 공공 시설관리기관의 시설관리 현황을 조사 분석하였다. 주요 조사 항목은 1) 시설 관리 시스템 구성 및 활용현황, 2) 중장기 수선 계획 수립 및 활용현황, 3) 수선대안 선정 시스템 수립 및 활용현황 등이다. 본 연구는 분석 자료를 기반으로 지방 공공 시설관리 기관에서 사용하고 있는 시설관리 시스템의 개선 사항을 도출하고 추후 연구 방향을 제시한다.

공간관리 현황조사를 통한 대학시설관리방안에 관한 연구 - 국립대학의 사례를 중심으로 (A Study on the Facility Management Method through Actual Condition of Space Management - Based on the National University)

  • 류수훈;이화룡
    • 교육시설
    • /
    • 제16권4호
    • /
    • pp.79-88
    • /
    • 2009
  • To enhance the administrational efficiency and for university facility and space management to be public, this research suggests a competent and an objective evaluation system and index. The study will assist national and university finances to contribute towards advanced education. Furthermore, figure out the space management condition of national university by utilizing the evaluation system, and through that suggesting efficient special management method. According to the result of this study, evaluation system for university facility can be widely divided into seven categories; system preparation, members conference, propriety of space allocation, propriety of management system, space use ratio, time control of space use, imposition index of surplus use. Based on these subdivisions, the space management category contains 19 evaluation items and the marking system allows perfect score of 100 points. In result of examining space management condition using the evaluation system, space management was well enforced in research focused university group where as in education centered university group, it shows relatively low enforcement. It also illustrated that efforts of evaluation items were required in categories of imposition index of surplus use and special use ratio in order for efficient space management.

탄소섬유강화플라스틱 재료 레저선박의 구조강도 평가를 위한 시험설비 구축과 운용에 관한 연구 (The Development of Structural Test Facility for the Strength Assessment of CFRP Marine Leisure Boat)

  • 정한구;장양;염덕준
    • 대한조선학회논문집
    • /
    • 제54권4호
    • /
    • pp.312-320
    • /
    • 2017
  • This paper deals with the development of structural test facility for the strength assessment of marine leisure boat built from carbon fiber reinforced plastics (CFRP) materials. The structural test facility consists of test jig, load application and control system, and data acquisition system. Test jig, and load application and control system are designed to accommodate various size and short span to depth ratios of single skin, top-hat stiffened and sandwich constructions in plated structural format such as square and rectangular shapes. A lateral pressure load, typical and important applied load condition to the plates of the hull structure for marine leisure boat, is simulated by employing a number of hydraulic cylinders operated automatically and manually. To examine and operate the structural test facility, five carbon/epoxy based FRP square plates having the test section area of $1m^2$, which are part of CFRP marine leisure boat hull, are prepared and they are subjected to monotonically increasing lateral pressure loads. In the test preparation, considering the symmetry of the plates geometry, various strain gauges and linear variable displacement transformer are used in conjunction with data acquisition system utilizing LabVIEW. From the test observation, the responses of the CFRP hull structure of marine leisure boat are understood by obtaining load to deflection and strain to load curves.

초고압 중전기기 절연시험설비 성능개선 연구 (A study on the performance improving of the dielectric test facilities for UHV heavy electric apparatus)

  • 이정기;김민규;정주영;김익수;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2100-2102
    • /
    • 2005
  • In this Paper, there have been brief review about the important consideration in laboratory planning and designing the dielectric testing facilities for heavy electric apparatus up to 800kV-class in the high voltage testing fields. To improve and reinforce the existing dielectric test facilities in the way of econo-mical and optimal condition, wide investigation and an analysis for a solution, especially overshoot compensation method. have been suggested. With the brief description about those matters in constructing and improving the test facilities, the specification of each facility has been shown in the paper.

  • PDF

가뭄 취약지역의 관정 효율 및 능력에 대한 취약성평가 (Vulnerability Evaluation of Groundwater Well Efficiency and Capacity in Drought Vulnerable Areas)

  • 신형진;이재영;조성문;전상민;김미솔;차상선;박찬기
    • 한국농공학회논문집
    • /
    • 제61권6호
    • /
    • pp.41-53
    • /
    • 2019
  • Recently, the damage caused by climate change has been distinguished in the world. The Korean Peninsula is also suffering from drought, so it is necessary to study the vulnerability assessment to identify and predict the state of the irrigation facility, which is a irrigation facility. As the damage caused by drought is occurring in the Korean peninsula, it is necessary to study the vulnerability assessment to know the condition of the irrigation facility, and to predict it. The target areas were Yeongdong-gun, Cheonan-si, Mungyeong-si, Geochang-gun, Muju-gun, and Yeonggwang-gun. The survey items were selected as positive impacts survey items, including precipitation, groundwater level, and pumping capacity per groundwater well. The negative impacts were selected as the cultivation acreage, Number of days without rain, and the ratio of private underground wells. The survey method was investigated by various methods such as "weather data portal", "groundwater level status information", "agricultural drought management system", "groundwater survey yearbook". The results of vulnerability assessment were expressed by the score by conducting survey and standardization. As a result, Yeonggwang-gun showed normal vulnerability, and other areas showed "vulnerable" or "very vulnerable".

터보샤프트 엔진 고공성능시험의 측정 불확도 평가 (Measurement Uncertainty Assessment of Altitude Performance Test for a Turboshaft Engine)

  • 양인영;이보화
    • 한국추진공학회지
    • /
    • 제14권4호
    • /
    • pp.59-64
    • /
    • 2010
  • 터보샤프트 엔진의 고공성능시험에서 주요 성능 인자인 축마력, 연료 유량, 비연료 소모율 및 공기유량에 대하여 측정의 수학적 모델을 제시하고 측정 불확도를 평가하였다. 터보제트 및 터보팬 엔진의 경우와 비교하여 차이점을 논의하였다. 시험 조건의 측정 불확도를 평가하였으며, 이를 보정된 성능 데이터 측정 불확도에 반영하는 방법을 제시하였다. 실제 터보샤프트 엔진 고공성능시험설비를 이용한 시험 사례에 대한 측정 불확도 평가 결과를 제시하였다. 주요 성능 인자의 측정 불확도는 시험 조건측정의 불확도를 반영하였을 경우 0.65~1.09%, 반영하지 않았을 경우 0.36~0.94%로 평가되었다.

중환자실 시설기준 작성을 위한 기본시설 수준 설정 연구 - 국내·외 시설기준 및 국내 종합병원 병상규모 별 시설 현황분석을 기초로 하여 (A Study to define the range of sample size for setting Intensive Care Unit(ICU) facility guidelines - Focused on analysis of guidelines and present of ICUs facilities by general hospitals size)

  • 윤형진;조준영
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권3호
    • /
    • pp.47-56
    • /
    • 2017
  • Purpose : This study is a basic research to establish guidelines for healthcare facility in Korean healthcare market. As a first step, it is a main purpose for making beginning point of ICU guideline to set a basic level of ICU facility size and quality by analysis current ICU facilities and existed domestic guidelines : law, criteria of healthcare insurance review and assessment service, credit of Korea institute for healthcare accreditation. Methods : First of all, the all requirements of existed guidelines are put together and summarized. The summary is compared with that of US, UK, and Australia to know its quality difference with international market. In addition, all hospitals in Korean market are classified based on total bed number and ICU bed number to know the most occupied facility size range in the market. Second of all, by comparing 15 ICUs' current setting of the public general hospital, a general condition of ICU facility would be extracted based on function, floor area per bed, services Results : 72.8% of hospitals in Korea are belonging below 500 beds hospital. Among them 200-299 beds hospitals occupied 35.3% and are shown as the most occupied hospital size. As 15 public general hospitals are analyzed, it is clear that the more bed size and services the more ICU area per bed. As a result it is sure that the 300~500 bed may be a clear line as a general ICU condition whose function and bed number relatively consistent in the range. Implications : to keep the qualified medical environment and contemporary hospital trend, the guideline as a minimum requirement keep naturally out from current healthcare settings and should reflect their limit to reconcile with the new trend in the market.

국내 청소년시설 대상 유지관리기반 안전점검 및 안전성 평가 연구 (Assessment of Degree and Safety Inspection Based on Maintenance Level in Domestic Youth Training Facility)

  • 이정석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2020
  • 최근 청소년을 대상으로 하는 다양한 시설물이 증가하고 있고, 그에 비해 안전기준 미흡, 사고사례 증가 및 유지관리 소홀 등 여러가지 문제점이 제기되고 있다. 이에 본 연구에서는 국내 청소년시설을 대상으로 최근 5년간(2015년~2019년) 수행한 안전점검 결과(총 1,858개소)를 토대로 현황을 조사하고, 주요 손상 및 결함 등 대표적 시설 특성을 분석하여 유지관리에 기반한 안전성을 평가하고자 한다. 이는 향후 청소년시설에서 나타나는 주요 손상 및 결함 특성을 토대로 경제적 관점의 보수 및 보강 방안을 제시하고자 하며, 안전 및 유지관리 차원의 기초자료로 활용하고자 한다.

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.