• Title/Summary/Keyword: Facility Capacity

Search Result 633, Processing Time 0.037 seconds

Analysis of Flood Reduction Effect of Washlands based on Variation of Rollway Characteristic (월류부특성변화에 따른 천변저류지군의 홍수저감효과분석)

  • Baek, Chun-Woo;Kim, Bok-Cheon;Ahn, Tae-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.145-150
    • /
    • 2009
  • Because it is difficult to install new large hydraulic structure, washland is considered as alternatives of hydraulic facility. As flood reduction effect of washland is dependent on flood, hydrograph, capacity of washland and spillway height, applying adequate spillway height is very important to maximize flood reduction effect of washland. In this study, effect of variation of spillway height on flood reduction effect of washlands is analyzed. The existing model developed to make decision for optimal location of washland using flood reduction effect as evaluation function and location of washland as decision variable was revised for this purpose. The spillway height of washland is added as decision variable and revised model finally give optimal location and spillway height of washland as result. The developed model has been applied to the Ansung River basin and application result was compared with that of existing model. The application result shows that developed model can give more efficient result than existing model.

An Application of GRID Architecture on a Part of Urban Facilities Management Based on U-GIS (U-GIS 기반 도시시설물 관리 분야의 그리드(GRID) 아키텍처 적용 연구)

  • Nam, Sang-Kwan;Oh, Yoon-Seuk;Ryu, Seung-Ki;Kwon, Hyuk-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.4
    • /
    • pp.113-124
    • /
    • 2009
  • A research of grid computing that is the combination of computer resources from multiple distributed administrative domains to get large amount of computing power is underway. This research is an application of grid technology on a urban facilities management system based on u-GIS. The sensors are set up in the urban facilities to make it monitoring. If an amount of sensors and gateways is increased, the server needs more computing resources to process the data. In this study we developed the skills that can distribute jobs to idle gateway, in case of the server capacity had approached threshold. It will be possible to develop of economic and efficient system that will apply to large amount of data processing about u-City.

  • PDF

Control of Seed Germination Rate (Chenopodium album var. centrorubrum, Portulaca oleracea and Eclipta prostrata) Using Universal Dispersed Microwave (마이크로웨이브 균일분산 특성을 이용한 명아주(Chenopodium album var. centrorubrum), 쇠비름(Portulaca oleracea)과 한련초(Eclipta prostrata)의 발아율 변화)

  • Choi, Sung Chul;Che, Min Ji;Kang, Shin Koo;Che, Sang Hoon
    • Korean Journal of Plant Resources
    • /
    • v.32 no.5
    • /
    • pp.478-485
    • /
    • 2019
  • As environmentally sound agriculture emphasize gradually as well as the importance of environment, many studies on weed and soil nematode control of new concept which does not affect adversely environment are in progress. For this purpose, plant seeds which are representative weed species in field were selected and treated with microwave having generating capacity of $17.73kw/m^3$, and investigated germination rates of weed seeds and the number of soil nematode according to soil moisture contents, soil depth and irradiation times. The microwave effect on the germination rates was extremely high in soil moisture content of 40% and irradiation time over 40 seconds for irradiation time, while soil depth did not affect germination rate. In view of the results so far achieved, it seems that universal dispersed microwave system is effective for the control of weed seeds.

Analysis of area-based optimal capacity design method in vegetation type LID (식생형 LID 시설에서 면적 기반의 적정 용량 설계 방법 연구)

  • Park, Seowon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 2018
  • Recently, it has been reported that water pollution due to non-point pollutants continues. Studies have been actively carried out to prevent such non-point pollutants from flowing into the water system and to prevent water pollution. In this study, to evaluate the adequate design of the LID facilities the rainfall corresponding to 80% of the cumulative rainfall of Yongin city was applied to an SA / CA graph obtained from the analysis of monitoring results of the vegetation type LID facility. As a result, the appropriate SA/CA ratio was 0.6% for stormwater sustain efficiency 80% and the appropriate SA/CA ratio was 0.5% for TSS removal efficiency 80%. The appropriate SA/CA ratio of the vegetation type LID proposed in this study can be used as a basis. for the future vegetation type LID design. If more data of vegetation type LID are added through continuous research, it will be more accurate.

Development of Evaluation Model of Pumping and Drainage Station Using Performance Degradation Factors (농업기반시설물 양·배수장의 성능저하 요인분석 및 성능평가 모델 개발)

  • Lee, Jonghyuk;Lee, Sangik;Jeong, Youngjoon;Lee, Jemyung;Yoon, Seongsoo;Park, Jinseon;Lee, Byeongjoon;Lee, Joongu;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.75-86
    • /
    • 2019
  • Recently, natural disasters due to abnormal climates are frequently outbreaking, and there is rapid increase of damage to aged agricultural infrastructure. As agricultural infrastructure facilities are in contact with water throughout the year and the number of them is significant, it is important to build a maintenance management system. Especially, the current maintenance management system of pumping and drainage stations among the agricultural facilities has the limit of lack of objectivity and management personnel. The purpose of this study is to develop a performance evaluation model using the factors related to performance degradation of pumping and drainage facilities and to predict the performance of the facilities in response to climate change. In this study, we focused on the pumping and drainage stations belonging to each climatic zone separated by the Korea geographical climatic classification system. The performance evaluation model was developed using three different statistical models of POLS, RE, and LASSO. As the result of analysis of statistical models, LASSO was selected for the performance evaluation model as it solved the multicollinearity problem between variables, and showed the smallest MSE. To predict the performance degradation due to climate change, the climate change response variables were classified into three categories: climate exposure, sensitivity, and adaptive capacity. The performance degradation prediction was performed at each facility using the developed performance evaluation model and the climate change response variables.

A Basic Study on the Mobile Separator and Sorter Development of Small and Medium-sized Discharge Site's Mixed Construction Waste in Rural Area (농촌지역 혼합건설폐기물의 중·소규모 배출현장용 이동식 분리선별기 개발을 위한 기초연구)

  • Kim, Byung-Yun;Park, Ji-Sun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.21 no.3
    • /
    • pp.17-24
    • /
    • 2019
  • This study aimed to develop a mobile separating and sorting device for discharge sites to separate and sort mixed construction waste generated in small and medium scale in small provincial cities into inorganic materials and combustible materials. The study results can be summarized as follows: 1) As a result of analyzing the existing domestic technology for the separating and sorting mixed construction waste, a device sorting the waste by fusing the vibration screen, disc screen, air blowing methods and the separating and sorting the combustible waste is applied in Korea. 2) In foreign countries, the air blowing, screen, gravity sorters are used for separating and sorting combustible waste in the same way as in Korea. Especially German T Company suggests a construction waste separating and sorting system using an optical sorter. 3) As for the test device for separating and sorting mixed construction waste to be buried in landfill, the processing capacity was set as 16 tons per day. 4) For separating and sorting inorganic materials by granularity, this study set a trommel with two types of diameter as a basic. To operate the mobile all-in-one system, the device is designed to locate a conveyor, a combustible waste conveying device, inside of the trommel. 5) The device is designed in a mobile mode under the concept of primary separating and sorting device, and it can be transported using a 2.5-ton truck minimum. The diameter and length of the trommel are designed to be within 1500mm and 3000mm, respectively. In a further study, an optimized separating and sorting technology is planned to be presented through an experimental study for processing efficiency analysis at the mixed construction waste site by manufacturing the pilot experiment facility reflecting the design elements in the result of this study.

A Study on Methods for Developing by Nurturing Clean Thermal Power Generation Technology (청정화력발전 기술 육성 방안 연구)

  • Kim, Yeong-Mi;Lee, Won-Hak
    • Journal of Climate Change Research
    • /
    • v.9 no.2
    • /
    • pp.197-207
    • /
    • 2018
  • The Korean government views coal-fired power plants as the key cause of the fine dust generation, and is developing an energy policy to replace and demolish old coal-fired power plants. According to the Eighth Power Supply Base Plan (2017-2031), the maximum power capacity in 2030 is expected to be 100.5GW, which is 17.9% higher than the current level (85.2GW). The plan aims to reduce the facility size and power generation ratio from nuclear and coal resources to even lower levels than today, and to rapidly expand power generation from new and renewable energy. Despite that, the proportion of coal power generation is still much higher than other resources, and it is expected that the reliance on goal will maintain for next several decades. Under such circumstances, the development, supply, and expansion of clean coal technology (CCT) that is eco-friendly and highly efficient, is crucial to minimize the emission of pollutants such as carbon dioxide and fine dust, as well as maximize the energy efficiency. The Korean government designated the Yong-Dong Thermoelectric Power Plant in Gangneung to develop clean coal power generation, and executed related projects for three years. The current study aims to suggest a plan to develop parts, technologies, testing, evaluation, certification, and commercialization efforts for coal-fired power generation, In addition, the study proposes a strategy to vitalize local economy and connect the development with creation of more jobs.

A Study on the Verification of water level criteria for forecasting system of reservoir failure (저수지 붕괴예보 시스템의 수위기준 검증 연구)

  • Lee, Baeg;Choi, Byounghan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • The loss of safety for reservoirs brought about by climate change and facility aging leads to reservoir failures, which results in the loss of lives and property damage in downstream areas. Therefore, it is necessary to provide a Reservoir Failure Forecasting System for downstream residents to detect the early signs of failure (with sensors) in real-time and perform safety management to prevent and minimize possible damage. For the verification of established water level management criteria, 10 water level data up to reservoir capacity was selected. Weight factor and trend line were applied to dramatic increase section of water level in the 1 year period data. The results shows that water level criteria based on three even parts shows less than 7% of standard deviation and it is appropriate to verify management criteria.

Development of Smart Factory Diagnostic Model Reflecting Manufacturing Characteristics and Customized Application of Small and Medium Enterprises (제조업 특성을 반영한 스마트공장 진단모델 개발 및 중소기업 맞춤형 적용사례)

  • Kim, Hyun-Deuk;Kim, Dong-Min;Lee, Kyung-Geun;Yoon, Je-Whan;Youm, Sekyoung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.3
    • /
    • pp.25-38
    • /
    • 2019
  • This study is to develop a diagnostic model for the effective introduction of smart factories in the manufacturing industry, to diagnose SMEs that have difficulties in building their own smart factory compared to large enterprise, to identify the current level and to present directions for implementation. IT, AT, and OT experts diagnosed 18 SMEs using the "Smart Factory Capacity Diagnosis Tool" developed for smart factory level assessment of companies. They analyzed the results and assessed the level by smart factory diagnosis categories. Companies' smart factory diagnostic mean score is 322 out of 1000 points, between 1 level (check) and 2 level (monitoring). According to diagnosis category, Factory Field Basic, R&D, Production/Logistics/Quality Control, Supply Chain Management and Reference Information Standardization are high but Strategy, Facility Automation, Equipment Control, Data/Information System and Effect Analysis are low. There was little difference in smart factory level depending on whether IT system was built or not. Also, Companies with large sales amount were not necessarily advantageous to smart factories. This study will help SMEs who are interested in smart factory. In order to build smart factory, it is necessary to analyze the market trends, SW/ICT and establish a smart factory strategy suitable for the company considering the characteristics of industry and business environment.

Geomechanical assessment of reservoir and caprock in CO2 storage: A coupled THM simulation

  • Taghizadeh, Roohollah;Goshtasbi, Kamran;Manshad, Abbas Khaksar;Ahangari, Kaveh
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.75-90
    • /
    • 2019
  • Anthropogenic greenhouse gas emissions are rising rapidly despite efforts to curb release of such gases. One long term potential solution to offset these destructive emissions is the capture and storage of carbon dioxide. Partially depleted hydrocarbon reservoirs are attractive targets for permanent carbon dioxide disposal due to proven storage capacity and seal integrity, existing infrastructure. Optimum well completion design in depleted reservoirs requires understanding of prominent geomechanics issues with regard to rock-fluid interaction effects. Geomechanics plays a crucial role in the selection, design and operation of a storage facility and can improve the engineering performance, maintain safety and minimize environmental impact. In this paper, an integrated geomechanics workflow to evaluate reservoir caprock integrity is presented. This method integrates a reservoir simulation that typically computes variation in the reservoir pressure and temperature with geomechanical simulation which calculates variation in stresses. Coupling between these simulation modules is performed iteratively which in each simulation cycle, time dependent reservoir pressure and temperature obtained from three dimensional compositional reservoir models in ECLIPSE were transferred into finite element reservoir geomechanical models in ABAQUS and new porosity and permeability are obtained using volumetric strains for the next analysis step. Finally, efficiency of this approach is demonstrated through a case study of oil production and subsequent carbon storage in an oil reservoir. The methodology and overall workflow presented in this paper are expected to assist engineers with geomechanical assessments for reservoir optimum production and gas injection design for both natural gas and carbon dioxide storage in depleted reservoirs.