• Title/Summary/Keyword: Facility Capacity

Search Result 633, Processing Time 0.033 seconds

Origin and Preservation Status of the 'Gongju Junghakdong Old Missionary House', the Registered Cultural Property No. 233 (등록문화재 제233호 '공주 중학동 구 선교사가옥'의 유래와 보존현황)

  • Suh, Mancheol;Kim, Sung Bae
    • Journal of Conservation Science
    • /
    • v.34 no.1
    • /
    • pp.11-21
    • /
    • 2018
  • The result of the study on the origin and preservation status of the 'Gongju Junghakdong old missionary house', the Registered Cultural Property No. 233, reveals that the building was approved on October 23, 1921, and missionary Alice H. Sharp was living in the building until her retirement from her missionary life of 39 years in Korea in 1939. In order to review internal and external preservation status of the building, condition of wood material, the composition of the window, the damage of the wall, and the leaning of the building were examined. In particular, in the case of window facilities, it is necessary to restore it to the original upper and lower sliding window. As a result of investigation of the preservation status of the external facilities, it is necessary to restore the original shape of the staircase and a deck of the building on south western side and the well. In addition, the results of the non-destructive diagnosis of the ground revealed that the building was built on uneven surface layer of 2-5 m thickness and the boundary between the surface layer and the upper part of the weathered rock is inclined following geomorphology. This phenomenon shows that when the water content of the ground increases in the rainy season, the bearing capacity of the ground is lowered, and there is a possibility of uneven subsidence. Especially, landslides may occur in case of heavy rain. Therefore, it is desirable to install a masonry facility at the southwest boundary of the site, and it is recommended to install a drainage facility to ensure rapid drainage.

Efficiency Assessment of Wastewater Treatment Plant and Groundwater Level by Pump and Treat Technology Applied for Petroleum Contaminated Site (유류오염 지하수 정화를 위한 양수처리법 적용시 지하수위 변화 및 수처리장치의 효율평가)

  • Cho, Chang-Hwan;Kim, Joon-Ho;Park, Min-Kyu;Kim, Tae-Hyung;Choi, Yoen-Soo;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.33-38
    • /
    • 2014
  • This study was performed to evaluate the applicability of pump and treat technology as well as to identify the changes of groundwater level by continuous pumping at the petroleum contaminated site. A total of 9 monitoring wells were installed at the site and the contaminant concentrations, TPH, benzene, toluene, ethylbenzene and xylene, of groundwater were measured. With the results of the groundwater monitoring, a total of 9 wells were set up for pumping contaminated groundwater in 3 locations. The waste water treatment facility with a capacity of $10m^3/hr$ was installed in the site and operated for about 1 year. The concentrations of the contaminated groundwater from the 3 pumping wells were exceeded groundwater regulation for benzene and TPH. However, the effluent concentration of benzene and TPH was under the regulation showing the maximum level of 0.011 mg/L and 1.2 mg/L during the operation periods. Groundwater levels were decreased by continuous pumping and those were not recovered during the operation period. Groundwater levels of PW-1,2, PW-3,4,5,6 and PW-7,8,9 were decreased about 5 m, 0.7 m, 2 m, respectively. The hydraulic conductivity (K) of the region of PW-1,2, PW-3,4,5,6 and PW-7,8,9 was estimated to be $6.143{\times}10^{-5}cm/sec$, $2.675{\times}10^{-5}cm/sec$, $1.198{\times}10^{-4}cm/sec$. Groundwater level was seemed to be affected not by hydraulic conductivity but by morphological effect. These results show that the pump and treat technology has high applicability for the restoration of petroleum contaminated groundwater but needs continuous monitoring to prevent rapid groundwater drawdown.

Flow Characteristics and Wind Loads on the Solar Panel and Floating System of Floating Solar Generato (부유식 태양광 발전기의 패널과 부유체에 작용하는 풍하중과 유동특성)

  • Ryu, Dae-Gyeom;Lee, Kye-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.229-235
    • /
    • 2019
  • A floating photovoltaic generation system is a new concept that combines existing photovoltaic generation technology with floating technology. This is installed in the water not on conventional land and a building. The system is designed as a unit module type that can be connected to other modules according to the power generation capacity, thereby forming a large-scale power generation facility. As a renewable energy source, it is composed of a floating structure, mooring device, photovoltaic power generation facility, and underwater cable. Because this system is installed outdoors, the effect of the wind load on the structure is very large. In this study, the wind loads most affected on the floating photovoltaic generation structure were obtained by computational fluid dynamic analysis. The flow characteristics and wind loads were analyzed for a range of wind orientations and angles of inclination. The analysis showed the position and magnitude of the maximum wind load to the wind direction and the flow characteristics around the solar panel and floating system. The wind load increased with increasing angle of inclination of the panel to the ground.

A Analytical Study on Seismic Performance of Stainless Water Tank using Lead Rubber Bearing (납고무받침을 이용한 스테인리스 물탱크 내진성능에 관한 해석적 연구)

  • Kim, Hu-Seung;Oh, Ju;Jung, Hie-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.230-236
    • /
    • 2018
  • Earthquakes over 5.0 on the Richter scale have recently occurred in Korea, which has led to interest in the seismic safety of structures. If a water storage facility is damaged by an earthquake, the water could leak, and the insufficient water would make fire suppression difficult. Therefore, a water storage facility should satisfy safety requirements for earthquakes. In this study, the seismic performance of a water tank was improved by installing a lead rubber bearing between the foundation and the tank. It designed the lead rubber bearing available to the existed concrete foundation. ANSYS was used for modeling to consider the interaction between the fluid and structure of the tank and the hydrostatic and hydrodynamic pressure using four seismic waves. In the case of hydrostatic pressure at 2.5 water level, full level, the same stress appeared irrespective of whether the seismic isolation was installed. When hydrostatic pressure and hydrodynamic pressures are applied at the same time, the seismic-isolated water tank showed less seismic force, and the damping ratio was lower than that of general seismic isolation. This occurred because the weight of the water tank is much smaller than the stiffness of the seismic isolation. The result is expected to be used for further research on seismic capacity evaluation for water tanks.

An experimental investigation of flow characteristics in the tangential and the multi-stage spiral inlets (접선식 및 다단식 나선 유입구 흐름 특성의 실험적 연구)

  • Seong, Hoje;Rhee, Dong Sop;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • The vulnerability of urban disasters is increased with the rapid urbanization and industrialization, and the extreme rainfall event is increased due to the global climate change. Urban inundation is also increased due to the extreme rainfall event beyond the capacity limit of facility for the damage prevention. The underground detention vault and the underground drain tunnel are rapidly being utilized to prevent urban inundation. Therefore, the hydraulic review and design analysis of the inlet of the underground facility are important. In this study, the water level of the approach flow according to the inflow discharge is measured and the flow characteristic of the inlet (tangential and spiral) is analyzed. For the spiral inlet, the multi-stage is introduced at the bottom of the inlet to improve the inducing vortex flow at low discharge conditions. In case of the tangential inlet, the discharging efficiency is decreased rapidly with hydraulic jump in the high flow discharge. The rising ratio of the water level in the multi-stage spiral inlet is higher than the tangential inlet, but the stable discharging efficiency is maintained at low and high discharge conditions. And the empirical formula of water level-flow discharge is derived in order to utilize inlets used in this study.

Analysis on the Runoff Reduction Efficiency of Non Point Pollutants in Animal Feeding Area Using Artificial Reservoir (인공 저류지를 이용한 축산 지역 비점오염물질 유출 저감 효율 분석)

  • Oa, Seong-Wook
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.417-423
    • /
    • 2018
  • It analyzed the efficiency of the runoff reduction of artificial reservoir by analyzing the influent and effluent of reservoir located downstream of the livestock area. Production of non point pollutants in livestock feeding areas, which is located at steep slope land, was mainly due to first flushes. Suspended Solid concentration of influent increased due to amount of rainfall, and T-P also increased over four times and 30 % of total nitrogen increased on average compared to those of dry season. While the concentration of nitrate nitrogen showed little variation, ammonia nitrogen increased over two times. The storage style nonpoint reduction facility showed the highest removal efficiency of 53 % for total phosphorus in dry weather, when the removal efficiency was 37 % for suspended solids, 10% for organic compounds, and 5 % for total nitrogen. Since algal bloom grows due to eutrophication in summer, the minus removal efficiencies of nitrogen concentration through the reservoir occurred with high frequency. Removal efficiency decreased during rainfall, showing 60 % for supended solids, and 22 % for total phosphorus. While having over nine times of capacity than the standard of non-point removal facility from Ministry of Environment, it was impounded with water during rainy season, showing not enough nonpoint removal efficiency, which indicates that maintenance is also an important factor to the nonpoint removal efficiency.

Comparative assessment of urban stormwater low impact strategies equipped with pre-treatment zones (침강지 시설이 조성된 LID 시설의 환경적 영향평가)

  • Yano, K.A.V.;Reyes, N.J.D.G.;Jeon, M.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.181-190
    • /
    • 2019
  • Recently, Low impact development techniques, a form of nature-based solutions (NBS), were seen cost-efficient alternatives that can be utilized as alternatives for conventional stormwater management practices. This study evaluated the effectiveness of an infiltration trench (IT) and a small constructed wetland (SCW) in treating urban stormwater runoff. Long-term monitoring data were observed to assess the seasonal performance and cite the advantages and disadvantages of utilizing the facilities. Analyses revealed that the IT has reduced performance during the summer season due to higher runoff volumes that exceeded the facility's storage volume capacity and caused the facility to overflow. On the other hand, the pollutant removal efficiency of the SCW was impacted by the winter season as a result of dormant biological activities. Sediment data also indicated that fine and medium sand particles mostly constituted the trapped sediments in the pretreatment and media zones. Sediments in SCW exhibited a lower COD and TN load due to the phytoremediation and microbiological degradation capabilities of the system. This study presented brief comparison LID facilities equipped with pre-treatment zones. The identified factors that can potentially affect the performance of the systems were also beneficial in establishing metrics on the utilization of similar types of nature-based stormwater management practices.

Application of CFD to Design Procedure of Ammonia Injection System in DeNOx Facilities in a Coal-Fired Power Plant (석탄화력 발전소 탈질설비의 암모니아 분사시스템 설계를 위한 CFD 기법 적용에 관한 연구)

  • Kim, Min-Kyu;Kim, Byeong-Seok;Chung, Hee-Taeg
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.61-68
    • /
    • 2021
  • Selective catalytic reduction (SCR) is widely used as a method of removing nitrogen oxide in large-capacity thermal power generation systems. Uniform mixing of the injected ammonia and the inlet flue gas is very important to the performance of the denitrification reduction process in the catalyst bed. In the present study, a computational analysis technique was applied to the ammonia injection system design process of a denitrification facility. The applied model is the denitrification facility of an 800 MW class coal-fired power plant currently in operation. The flow field to be solved ranges from the inlet of the ammonia injection system to the end of the catalyst bed. The flow was analyzed in the two-dimensional domain assuming incompressible. The steady-state turbulent flow was solved with the commercial software named ANSYS-Fluent. The nozzle arrangement gap and injection flow rate in the ammonia injection system were chosen as the design parameters. A total of four (4) cases were simulated and compared. The root mean square of the NH3/NO molar ratio at the inlet of the catalyst layer was chosen as the optimization parameter and the design of the experiment was used as the base of the optimization algorithm. The case where the nozzle pitch and flow rate were adjusted at the same time was the best in terms of flow uniformity.

Prediction of Hydrodynamic Behavior of Unsaturated Ground Due to Hydrogen Gas Leakage in a Low-depth Underground Hydrogen Storage Facility (저심도 지중 수소저장시설에서의 수소가스 누출에 따른 불포화 지반의 수리-역학적 거동 예측 연구)

  • Go, Gyu-Hyun;Jeon, Jun-Seo;Kim, YoungSeok;Kim, Hee Won;Choi, Hyun-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.107-118
    • /
    • 2022
  • The social need for stable hydrogen storage technologies that respond to the increasing demand for hydrogen energy is increasing. Among them, underground hydrogen storage is recognized as the most economical and reasonable storage method because of its vast hydrogen storage capacity. In Korea, low-depth hydrogen storage using artificial protective structures is being considered. Further, establishing corresponding safety standards and ground stability evaluation is becoming essential. This study evaluated the hydro-mechanical behavior of the ground during a hydrogen gas leak from a low-depth underground hydrogen storage facility through the HM coupled analysis model. The predictive reliability of the simulation model was verified through benchmark experiments. A parameter study was performed using a metamodel to analyze the sensitivity of factors affecting the surface uplift caused by the upward infiltration of high-pressure hydrogen gas. Accordingly, it was confirmed that the elastic modulus of the ground was the largest. The simulation results are considered to be valuable primary data for evaluating the complex analysis of hydrogen gas explosions as well as hydrogen gas leaks in the future.

Measures to improve the legal system for commercialization of sand dams (샌드댐 상용화를 위한 법제도 개선 방안)

  • Shim, Young-Gyoo;Chung, Il-Moon;Kim, Min-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.635-643
    • /
    • 2022
  • Attempts are being made to use the sand dam as an alternative water resource securement facility by installing and operating sand dams in valleys, where water intake capacity is extremely limited, in areas with limited water supply in the upstream watershed of Korea. In the case of some countries in Africa, where sand dams are known to be most actively installed and used, it is difficult to find examples of establishing and applying a separate legal system for sand dams. A sand dam is a kind of groundwater dam, and in view of its concept, structural and technical form and characteristics, purpose, use, and function, it will be said that it has the legal character and status as a facility for securing groundwater resources specified in the current 「Ground Water Act」. Interpretation and application of regulations on facilities for securing groundwater resources also supports this. Therefore, it is legal and realistic to promote and implement the sand dam project as one of the installation and management projects for securing underground water resources based on the 「Ground Water Act」.